There may be occasions during Dual Receive operation
when you want to silence the VFO-A receiver temporarily,
to concentrate on the signal being received on the VFO-B
receiver. The Mute feature makes this simple to accom-
plish.
Press the ( VFO-A )[ RX ] button briefly, located to the up-
per left of the Main Tuning Dial knob. The VFO-A re-
ceiver will be silenced, and the green LED in the ( VFO-
A )[ RX ] button will blink.
To restore reception on the VFO-A receiver, just press the
blinking ( VFO-A )[ RX ] button once more.
A
:
If you press the [ POWER ] switch briefly while the trans-
ceiver is turned on, the transceiver audio will be muted for
three seconds.
The FT
5000 includes a adjustable receiver audio filter, that provides precise, independent control of the low- and upper-
DX
ranges.
1. Press the [ MENU ] button briefly, to enter the Menu
mode.
2. Rotate the ( VFO-A )[ SELECT ] knob to find Menu
items "047" through "050"; these parameters apply to
the adjustment of the receiver audio filter in the AM
mode, Menu items "053" through "056" apply to the
adjustment of the RX audio filter in the CW mode,
Menu items "075" through "078" apply to the adjust-
ment of the RX audio filter in the FM mode, Menu
items "089" through "092" apply to the adjustment of
the RX audio filter in the RTTY mode, and Menu items
"099" through "102" apply to the adjustment of the
RX audio filter in the SSB mode.
3. Rotate the ( VFO-B )[ SELECT ] knob to perform ad-
justments to a particular Menu item.
You may confirm the change of the sound quality from
the speaker or headphones.
4. When you have completed all adjustments, press and
hold in the [ MENU ] button for two seconds to save
the new settings and exit to normal operation. If you
only press the [ MENU ] button momentarily to exit,
any changes you performed will not be stored.
FT
5000 O
DX
PERATING
C
OMFORTABLE AND
M
F
UTE
EATURE VFO-A B
A
R
DJUSTABLE
ECEIVER
M
ANUAL
E
FFECTIVE
AND
[ POWER ] Switch
[ A ] Button
A
F
UDIO
ILTER
AM
047 A3E LCUT FRQ
048 A3E LCUT SLP
049 A3E HCUT FRQ
050 A3E HCUT SLP
CW
053 A1A LCUT FRQ
054 A1A LCUT SLP
055 A1A HCUT FRQ
056 A1A HCUT SLP
FM
075 F3E LCUT FRQ
076 F3E LCUT SLP
077 F3E HCUT FRQ
078 F3E HCUT SLP
089 RTTY LCUT FRQ OFF / 100 ( Hz ) ~ 1000 ( Hz )
RTTY
090 RTTY LCUT SLP
091 RTTY HCUT FRQ 700 ( Hz ) ~ 4000 ( Hz ) / OFF
092 RTTY HCUT SLP 6dB/oct or 18dB/oct
SSB
099 A3J LCUT FRQ
100 A3J LCUT SLP
101 A3J HCUT FRQ
102 A3J HCUT SLP
R
ECEPTION
( VFO-A )[ SELECT ] Knob
[ MENU ] Button
( VFO-B )[ SELECT ] Knob
OFF / 100 ( Hz ) ~ 1000 ( Hz )
6dB/oct or 18dB/oct
700 ( Hz ) ~ 4000 ( Hz ) / OFF
6dB/oct or 18dB/oct
OFF / 100 ( Hz ) ~ 1000 ( Hz )
6dB/oct or 18dB/oct
700 ( Hz ) ~ 4000 ( Hz ) / OFF
6dB/oct or 18dB/oct
OFF / 100 ( Hz ) ~ 1000 ( Hz )
6dB/oct or 18dB/oct
700 ( Hz ) ~ 4000 ( Hz ) / OFF
6dB/oct or 18dB/oct
6dB/oct or 18dB/oct
OFF / 100 ( Hz ) ~ 1000 ( Hz )
6dB/oct or 18dB/oct
700 ( Hz ) ~ 4000 ( Hz ) / OFF
6dB/oct or 18dB/oct
Page 69

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FTdx5000MP and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Ftdx5000Ftdx5000dFtdx5000 series

Table of Contents

Save PDF