Download Print this page

Mitsubishi Electric FR-D740-012-EC Installation Manuallines page 17

Hide thumbs Also See for FR-D740-012-EC:

Advertisement

PARAMETER LIST
Name
Parameter
45
Second deceleration time
46
Second torque boost
47
Second V/F (base frequency)
Second stall prevention
48
operation current
Second electronic thermal O/L
51
relay
DU/PU main display data
52
selection
Frequency monitoring
55
reference
56
Current monitoring reference
57
Restart coasting time
58
Restart cushion time
59
Remote function selection
Energy saving control
60
selection
65
Retry selection
Stall prevention operation
66
reduction starting frequency
Number of retries at fault
67
occurrence
68
Retry waiting time
69
Retry count display erase
Special regenerative brake
70
duty
71
Applied motor
72
PWM frequency selection
73
Analog input selection
74
Input filter time constant
Reset selection/disconnected
75
PU detection/PU stop
selection
77
Parameter write selection
Reverse rotation prevention
78
selection
79
Operation mode selection
80
Motor capacity
82
Motor excitation current
83
Motor rated voltage
84
Rated motor frequency
14
Setting
Initial
Parameter
Range
Value
0 to 3600s,
9999
9999
0 to 30%,
9999
9999
0 to 400Hz,
9999
9999
0 to 200%,
9999
9999
0 to 500A,
9999
9999
0, 5, 8 to 12,
14, 20, 23 to
25, 52 to 55,
0
61, 62, 64,
100
0 to 400Hz
50Hz
Rated
0 to 500A
inverter
current
0, 0.1 to 5s,
9999
9999
0 to 60s
1s
0, 1, 2, 3
0
0, 9
0
0 to 5
0
0 to 400Hz
50Hz
0 to 10, 101
0
to 110
0.1 to 600s
1s
0
0
0 to 30%
0%
0, 1, 3, 13,
23, 40, 43,
0
50, 53
0 to 15
1
0, 1, 10, 11
1
0 to 8
1
0 to 3, 14 to
14
17
0, 1, 2
0
0, 1, 2
0
0, 1, 2, 3, 4,
0
6, 7
0.1 to 7.5kW,
9999
9999
0 to 500A,
9999
9999
200V/
0 to 1000V
400V
∗5
10 to 120Hz
50Hz
Name
90
Motor constant (R1)
96
Auto tuning setting/status
PU communication station
117
number
118
PU communication speed
PU communication stop bit
119
length
PU communication parity
120
check
Number of PU communication
121
retries
PU communication check time
122
interval
PU communication waiting
123
time setting
PU communication CR/LF
124
selection
Terminal 2 frequency setting
125
gain frequency
Terminal 4 frequency setting
126
gain frequency
PID control automatic
127
switchover frequency
128
PID action selection
129
PID proportional band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
145
PU display language selection 0 to 7
146
Parameter for manufacturer setting. Do not set.
150
Output current detection level
Output current detection signal
151
delay time
152
Zero current detection level
153
Zero current detection time
Stall prevention operation
156
selection
157
OL signal output timer
158
AM terminal function selection
Extended function display
160
selection
Frequency setting/key lock
161
operation selection
Setting
Initial
Range
Value
0 to 50Ω,
9999
9999
0, 11, 21
0
0 to 31 (0 to
0
247)
48, 96, 192,
192
384
0, 1, 10, 11
1
0, 1, 2
2
0 to 10, 9999
1
0, 0.1 to
999.8s,
0
9999
0 to 150ms,
9999
9999
0, 1, 2
1
0 to 400Hz
50Hz
0 to 400Hz
50Hz
0 to 400Hz,
9999
9999
0, 20, 21, 40
0
to 43
0.1 to
100%
1000%, 9999
0.1 to 3600s,
1s
9999
0 to 100%,
9999
9999
0 to 100%,
9999
9999
0 to 100%,
9999
9999
0.01 to
9999
10.00s, 9999
1
0 to 200%
150%
0 to 10s
0s
0 to 200%
5%
0 to 1s
0.5s
0 to 31, 100,
0
101
0 to 25s,
0s
9999
1 to 3, 5, 8 to
12, 14, 21,
1
24, 52, 53,
61, 62
0, 9999
9999
0, 1, 10, 11
0

Hide quick links:

Advertisement

loading