Sharp MD-DR470HS Service Manual page 21

1-bit portable minidisc recorder
Table of Contents

Advertisement

* If the [PLAY] button is pressed in the B-ATT setting state, the mode is changed to the continuous
playback mode.
And if the [Remote Controller MODE] button is pressed in the continuous playback state, the mode is
changed to the B-ATT setting state of the ATT manual adjustment.
H B
L b
L B
PLAY
MODE
S Q # # # #
A P # # # #
* If the [Remote Controller BASS] button is pressed in the laser ON state (with no disc or the lid open),
laser power changes as follows.
Playback power
BASS
L O N
P
* In the specific setting display state the setting change digit changes when the [REC] button is pressed.
1st digit (initial value)
* In the specific state the setting changes in the range of "0h to Fh" when the [VOLUME UP/DOWN]
button is pressed.
* If the [DISP] button is pressed, the display changes as follows.
• LPFABO measurement value
H A
H B
L a
L b
L A
L B
DISP
DISP
a b
• TCRSMIO measurement value
G C
DISP
DISP
T C
• LPFEINO/EFMIO measurement value
P E
G E
DISP
e i
DISP
E F
DISP
• LPFFINO/EFMIO measurement value
P F
G F
DISP
f i
DISP
E F
DISP
: High-reflection pit section B-ATT (focus) setting
: Low-reflection pit section B-ATT (focus) setting
: Low-reflection groove section B-ATT (focus) setting
: ATT setting
: Continuous playback (pit section)
: Continuous playback (groove section)
# # # # : Address
Record power
BASS
L O N
R
L O N
2nd digit
REC
: High-reflection pit section A-ATT (focus) setting
: High-reflection pit section B-ATT (focus) setting
: Low-reflection pit section A-ATT (focus) setting
: Low-reflection pit section B-ATT (focus) setting
: Low-reflection groove section A-ATT (focus) setting
: Low-reflection groove section B-ATT (focus) setting
: LPFABO measurement value indication
"1" Mark lighting
: TCRS ATT setting
: TCRSMIO measurement value indication
"1" Mark lighting
: Pit section E-ATT (tracking) setting
: Groove section E-ATT (tracking) setting
: LPFEINO measurement value indication
"1" Mark lighting
: EFMIO measurement value indication
"REPEAT", "1" Mark lighting
: Pit section F-ATT (tracking) setting
: Groove section F-ATT (tracking) setting
: LPFFINO measurement value indication
"1" Mark lighting
: EFMIO measurement value indication
"REPEAT", "1" Mark lighting
– 21 –
MD-DR470H/MD-DR480H
Maximum power
M
BASS
3rd digit
REC
REC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Md-dr470hMd-dr470hblMd-dr480hMd-dr480hsMd-dr480hbl