Additional Functions; Single Wheel Test; Noise Investigation - MAHA SA 2 Euro Operation & Maintenance Manual

Table of Contents

Advertisement

PC Program Operation
4.8

Additional Functions

4.8.1

Single Wheel Test

With a single wheel measurement only the roller set of one side is started on the test stand.
First, switch to the proper mode to conduct a single wheel test.
1 Use <7> Test procedure in the main menu.
The screen opposite will appear.
2 Use <7> to switch between the five
settings. Confirm with <RETURN>.
3 Exit the screen with <ESC> and return to
the main menu.
4 After the single wheel test switch off the
special mode in the same way.
5 The test procedure has already been
described in section 3.5.
4.8.2

Noise Investigation

Use the noise investigation mode to detect noise sources and possible damage on wheel and
suspension. Only one plate at a time is started on the shock absorber test stand. No
measurement values are recorded.
1 Before driving onto the shock absorber
tester, activate the noise detection mode
using the switch on the sidewall of the
control cabinet.
2 Use <7> Test procedure in the main menu.
The screen opposite appears.
3 Activate the noise investigation with <F6>.
The following screen appears.
4 After driving onto the shock absorber plates
the wheel weights will be shown.
5 Use <F6> (or <F7>) to start the left (or
right) test plate.
6 The test plate vibrates until it is switched off
with <F5>.
7 Use <ESC> to exit the screen and the noise
investigation mode.