Download Print this page
Sealey 6-24V AUTO PROBE PLUS Quick Start Manual

Sealey 6-24V AUTO PROBE PLUS Quick Start Manual

6-24v auto probe plus

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instructions
protection
1. SAFETY
DO NOT use the unit around explosive gas, vapor, or dust.
8
When the rock switch is pressed (or rocked), battery current is conducted directly to the tip which may cause sparks when
8
contacting ground or certain circuits.
The unit is not to be used with 110/220-volt domestic mains supply, it is only for use with DC 6 - 24V systems.
8
DO NOT use on AC voltage.
8
After working on a vehicle, correctly restore all the connections which were disconnected.
9
Always follow the instructions and procedures indicated in the manufacturer's service manual before attempting to disconnect any
9
part or subsystem of the electrical circuit.
Use caution when using the unit to perform measurement. Never touch any dangerous part of the vehicle, for safety.
9
DO NOT touch any live conductor with hand or skin.
8
DO NOT use probe if it is damaged.
8
Some components of vehicle work on lower voltage, they can not withstand the voltage applied by the unit. To avoid damage to
9
these components, don't use the unit to apply voltage to them directly or indirectly.
Before driving vehicle, always make sure that the vehicle is safe and reliable.
9
DO NOT use the unit if the vehicle is being driven.
8
2. INTRODUCTION
6-24V Auto Probe with an integral work light to aid use in dark engine bays plus an audible circuit tester for when the LED on the probe cannot
be seen.
3. FEATURES
1
Red battery clip
2
Black battery clip
3
Probe
4
Work lights
5
'Touch contact' to turn on the lights
6
Test indicator
7
Rock switch
It includes a front part " - ", and a rear part "= ".
When pressed the front part" - ", the probe is connected to
the red battery clip directly.
When you press the rear part"=", the probe is connected to
the black battery clip directly.
8
Auxiliary ground lead
4. OPERATION
4.1.
CONNECTION
4.1.1.
Unroll the unit's cable. Clamp the red battery clip to the positive
terminal of the vehicle's battery.
4.1.2.
Clamp the black battery clip to the negative terminal of the
vehicle's battery.
4.1.3.
The unit starts self-test, the built-in buzzer sounds,
the test indicator's green light, red light and the
work lights light in turn.
4.1.4.
Several seconds later, the self-test finishes.
Note: The buzzer sounds continuously and then sounds intermittently.
© Jack Sealey Limited
6-24V AUTO PROBE PLUS
PPX.V4
MODEL NO:
Original Language Version
PPX.V4 Issue 1 06/06/22

Advertisement

loading

Summary of Contents for Sealey 6-24V AUTO PROBE PLUS

  • Page 1 PPX.V4 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 The contact of the tip is a direct ground or negative voltage. b. The component is short-circuited. c. The component is a high amperage component ( i.e. starter motor). Original Language Version PPX.V4 Issue 1 06/06/22 © Jack Sealey Limited...
  • Page 3 The black battery clip and the auxiliary ground lead are connected directly through the unit. By leaving the red battery clip disconnected from the vehicle’s battery, the unit can be used as a long jumper lead. 4.9.2. Be careful to avoid short circuit and overloading when using this jumper function. In this configuration, the leads are not protected by the unit’s built-in circuit breaker. Original Language Version © Jack Sealey Limited PPX.V4 Issue 1 06/06/22...
  • Page 4 Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call our technical team on technical@sealey.co.uk or 01284 757505. Important: No Liability is accepted for incorrect use of this product.

This manual is also suitable for:

Ppx.v4