Alarm Output Status

Alarm Status
High
(fail safe)
High
(non fail safe)
Low
(fail safe)
Low
(non fail safe)
Note
: *SSS is the solid state switch

Definitions

Alarm Conditions as defined below can be detected in a fail-safe or non fail-safe mode.
Fail Safe
The sensor connection arrangement of the CLS 100 is fail-safe if the output status is in
alarm status when power fails, which is an open contact state.
The sensor connection arrangement of the CLS 100 switches to the alarm status when
power fails, which is an open contact state.
High Alarm
Condition in which the material has reached a maximum level for the process (probe
covered).
Low Alarm
Condition in which the material has reached a minimum level for the process (probe
uncovered).
7ML19985AU01.1
Covered
Yellow LED ON
Red LED OFF
4mA
SSS* = open
Red LED ON
20mA
SSS = closed
Red LED ON
20mA
SSS = closed
Red LED OFF
4mA
SSS = open
Pointek CLS 100
Uncovered
Yellow LED OFF
Red LED ON
20mA
SSS = closed
Red LED OFF
4mA
SSS = open
Red LED OFF
4mA
SSS = open
Red LED ON
20mA
SSS = closed
Power
Connection
Black wire + V
Red wire + V
Red wire + V
Black wire + V
Page 12