4. Select "EXT232C" using
Exit
Service : Board Slot 7 SY MAIN
Param
>EXT232C
-1- -2- -3- -4- -5- -6- -7- -8-
Rdy Rdy Rdy Reg Rdy Rdy Rdy Rdy
5. Press the [ENTER] button several times and display "SY MAIN".
Exit
Service : Board Slot 7 SY MAIN
Param
>EXT232C
-1- -2- -3- -4- -5- -6- -7- -8-
Rdy Rdy Rdy Reg Rdy Rdy Rdy Rdy
6. Exit the menu.
7. Turn on the power of personal computer and activate Windows 95.
8. Activate the terminal software (Hyperterminal).
9. Set the communication rate.
Communication port
Baud rate
Parity
Flow control
Stop bit length
Data bit length
10. Open the recording file (e.g., ABC file).
Command : DPM \ TOMCP \ DISK \ OPENREC \ 01 \ 00 \ 00 \ ABC "
11. Confirm the file handle.
Command : DPM \ DUMP \ OPENSTATUS "
Return From MAV-70 :
PORT=01 : 08 01 01 04
PORT=02 : 00 00 00 00
PORT=03 : 00 00 00 00
Slot number
12. Start the recording.
Command : DPM \ TOMCP \ DISK \ REC \ 01 "
MAV-70
and
buttons and "-7-" (SY-253 board) using
COM1
38,400 bps
None
None
1
8
Slot number in which the ENC-47 board is inserted
The third numerical value is
a file handle.
File handle
3-8. AD-156 Board Adjustment
and
buttons.