Motorola M68HC08 Reference Manual page 96

Sensorless bldc motor control using the mc68hc908mr32
Hide thumbs Also See for M68HC08:
Table of Contents

Advertisement

Software Design
Designer Reference Manual
96
Freescale Semiconductor, Inc.
Second Commutation
The commutation time (T2) is calculated from the previous
commutation time and the start commutation period (Per_CmtStart).
This time is set to timer 2. Then, the new PWM multiplexer logic data
is readied for when the commutation interrupt performs the next
commutation.
The calculation of the commutation time is explained in
Starting — Commutation Time
Measurements Handler
As explained in
Scheduler
current is scanned and over-current condition is evaluated. Where
there is an over-current, the control enters the fault state (see
State). The voltage and the speed commands are scanned too. When
this state is finished, the values of dc-bus current, dc-bus voltage, and
speed command are updated.
Software Design
For More Information On This Product,
Go to: www.freescale.com
Calculation.
and
Over-Current
Detection, the dc-bus
3.3.1.5
Fault
DRM028 — Rev 0
MOTOROLA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mc68hc908mr32

Table of Contents