Download Print this page
Kenmore 596.78079891 Technical Information
Kenmore 596.78079891 Technical Information

Kenmore 596.78079891 Technical Information

Room air conditioner

Advertisement

Quick Links

https://appliancetechmanuals.com
Kenmore Technical Information³Room Air Conditioner
Model 596.78079891
• Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this air conditioner.
• Refer to Service Manual for operation, disassembly, testing, and troubleshooting information.
• Refer to Repair Parts List 20110801 for part number information.
All safety information must be followed as provided in Service Manual for this device.
To avoid risk of electrical shock, personal injury, or death, disconnect power to unit and discharge capacitor
through a 10,000 ohm resistor before servicing, unless testing requires power. Wires removed during
disassembly must be replaced on proper terminals to ensure correct grounding and polarization.
Model
Electrical requirements
Refrigerant/amount
Compressor
Voltage low/high (nominal)
Btuh
Watts
Current
Lock rotor
Full load
Overload protector
Close temperature
Open temperature
Short time trip:
Time
Amps
Fan motor
Electrical requirements
RPM
Low speed
Medium speed
High speed
Watts at high speed
Amps at high speed
Capacitor
Capacitance
Voltage rating (nominal)
November 1998
6,600 Btu
!
CAUTION
!
WARNING
596.78079891
115 VAC 60Hz
HCFC22/14 ounces
103.5/126.5 VAC (115 VAC)
6700 Btuh
655.5 watts
36.2 amps
5.7 amps
142°F ±16°F (61°C ±9°C)
257°F ±9°F (125°C ±5°C)
11 +5/-4.5seconds
26.5 amps
115 VAC 60Hz
700 RPM
800 RPM
900 RPM
82.8 watts
0.57 amps
35/7.5 Mfd ±10%
370 VAC
1
20110901 Revision 0

Advertisement

loading

Summary of Contents for Kenmore 596.78079891

  • Page 1 Kenmore Technical Information³Room Air Conditioner Model 596.78079891 6,600 Btu • Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this air conditioner. • Refer to Service Manual for operation, disassembly, testing, and troubleshooting information.
  • Page 2 https://appliancetechmanuals.com Component Specifications WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to unit and discharge capacitor through a 10,000 ohm resistor before servicing, unless testing requires power. Wires removed during disassembly must be replaced on proper terminals to ensure correct grounding and polarization. Illustration Component Test Procedure...
  • Page 3 https://appliancetechmanuals.com Service Specifications WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to unit and discharge capacitor through a 10,000 ohm resistor before servicing, unless testing requires power. Wires removed during disassembly must be replaced on proper terminals to ensure correct grounding and polarization. Cooling Wattage Input Chart Amperage Chart—Cooling Outside Air...
  • Page 4 10,000 ohm resistor before servicing, unless testing requires power. Wires removed during disassembly must be replaced on proper terminals to ensure correct grounding and polarization. Compressor 11101504 Fan motor 20109901 Blower wheel 20109701 Capacitor D6879845 Overload D6961654 Control board 20103501 Model 596.78079891 20110901 Revision 0 November 1998...