Line
Function
850
I
Floor curing function
- Off : Early interruption of the current programme, programme inactive.
- Operational heating.
- Heating ready for occupation.
- Operational heating + ready heating.
- Ready heating + operational heating.
- Manual: Manual mode enables you to programme your own concrete slab drying time.The function ends automatically
after 25 days.
55
50
45
40
35
30
25
20
0 1
5
X
Heating ready for occupation
1
Operational heating + Heating ready for occupation
fi g. 51 - Diagram of the concrete slab drying programmes
851
I
Floor curing setpoint manually
(if line 850 = manual)
This function enables you to set the custom concrete slab drying temperature. This temperature remains fi xed.
The concrete slab-drying programme stops automatically after running for 25 days.
856
I
Floor curing day current
857
I
Floor curing day completed
900
S
Operating mode changeover
Operating mode at end of concrete slab drying period
Cooling circuit 1
If the installation is fi tted with the cooling kit (Only with the cooling kit option).
901
U
Operating mode
902
U
Comfort cooling setpoint
903
U
Reduced setpoint
908
I
Flow temp setp at OT° 25°C
909
I
Flow temp setp at OT° 35°C
912
I
Cooling limit at OT°
913
S
Lock time at end of heating / cooling
918
S
Summer comp start at OT°
919
S
Summer comp end at OT°
920
S
Summer comp setp increase
923
S
Flow temp setp min OT° 25°C
924
S
Flow temp setp min OT° 35°C
- 52 -
(fi g.
51)
10
18 1
Operational
Setting range
or display
5
7
Day
heating
25
0... 95 °C
0... 32
0... 32
None, Protection mode,
Reduced, Comfort, Automatic
Protection, Automatic, Reduced,
Comfort
5... 40 °C
5... 40°C
6... 35 °C
6... 35 °C
--, 8... 35 °C
--, 8... 100
20... 50 °C
20... 50 °C
--, 1... 10 °C
6... 35 °C
6... 35 °C
Waterstage Split Comfort DHW Serie / INSTALLATION / 2125 - EN
Setting
increment
Please
comply
standards
and
instructions
of
the
manufacturer
building ! A good performance
of this function is only possible
with an installation correctly
implemented
electricity and adjustments) !
This function can be stopped
by anticipation when setting the
adjustment on "Off ".
1 °C
1
Protection
0.5 °C
0.5 °C
0.5 °C
0.5 °C
1 h
1 °C
1 °C
1 °C
0.5 °C
0.5 °C
Basic
setting
Off
with
the
of
the
(hydraulic,
25 °C
0
0
Reduced
24 °C
26 °C
20 °C
16 °C
24 °C
24 h
26 °C
40 °C
4 °C
18 °C
18 °C