HOW TO INSTALL ELECTRIC HOME SHOWER

• Proper size of Flexible Cord and electric wiring must be installed to avoid smoke emission and fire hazards.
• During installation process make sure electric and water supply are turned "OFF".
• The home shower must be permanently connected to the electric supply through the ON/OFF DP (double
pole) Switch having a contact separation of at least 3 mm in all poles incorporated in the fixed wiring. This
switch must be clearly identifiable but out of reach of a person using a fixed bath or shower.
The Unit must be earthed.
Improper grounding could cause electric shock.
• Never install Filter Body Assembly at the outlet, inlet water cannot be filtered and allows
foreign particles to enter the Unit. It will cause Heater Unit and Shower Head to clog up.
• Do not install, remove and reinstall the Unit by yourself.
Improper installation will cause leakage, electric shock or fire. Installation and wiring must be
done by competent personnel.
• Do not share the inlet and outlet pipe of the Home Shower Unit with other outlets.
The pressure may drop due to water being drawn off at other point. The shower temperature
may become very hot.
• Flexible Cord must enter the Unit thru designated point only (do not make additional holes).

1. BEFORE INSTALLATION

(1) Make sure water flow pressure.
Min. water pressure
Min. water pressure
Max. water pressure
How to measure the water pressure as illustrated. Water should flow out of the
Hose 2.0 m above the Main Water Valve.
Note:
When removing the Unit from package, some water may be found inside.
This is normal as the Unit is tested during the manufacturing process.

2. HOW TO INSTALL

WARNING
During installation process make sure electric
and water supply is turn "OFF".
1. Where to install the Unit.
• Be sure to install the Unit on the wall as illustrated in
Figure 1 (vertical condition only).
• Do not install the Unit away from wall surface as
shown in Figure 2.
• The Unit must be installed at 1.5 m ~ 1.7 m above
the floor.
2. How to remove the Front Plate
① Make sure the Power Control Knob is at "OFF"
condition.
② Remove the screw at the bottom of the Unit.
③ Lift up the Power Control Knob to make it free
(Power Control Knob is attached to "VR Shaft"
inside the Unit). Make sure the Power Control
Knob is not detached from the Front Plate.
④ Remove the Front Plate by lifting up the bottom side
and then unhook the top side.
WARNING
CAUTION
9.8 kPa / 0.1 kgf/cm² / 1.42 psi (DH-3NS1 & DH-3NS2)
4.9 kPa / 0.05 kgf/cm² / 0.71 psi (DH-3NP2)
380 kPa / 3.87 kgf/cm² / 55 psi
Cold Water
For DH-3NP2
- 25 -
Main Pipe Rising Level
Tank
33 ft (10 meters)
Service
maximum recommended
Valve
height between bottom
of cold water tank and
top of shower Units.
* Maximum total length
Off
High
ELB
ELB Test
of feeding pipe should
Push Up
ELB Reset
Push On-Off
be below 10 m.
* The feeding pipe
should be 1/2 inch.
1.5 m ~
1.7 m
For DH-3NS1/DH-3NS2
Note
Power Control Knob attached to Front Plate.
Off
High
ELB
Off
High
ELB Test
ELB
Power Control
ELB Reset
Push On-Off
Push Up
DH-3NS1
Knob
Off
High
ELB
ELB Test
Push Up
ELB Reset
Push On-Off
DH-3NS1
Water
Volume
Knob
Water Outlet
Water Inlet
2.0 m
Figure 1
Off
High
ELB
ELB Test
ELB Reset
Push Up
Push On-Off
DH-3NS1
1.5 m ~
1.7 m
Figure 2
Power Control Knob
Front Plate
Lift up