POWER P.C.B. CHECK
It is possible to check the Power P.C.B. only with no load.
Power P.C.B. Service Position
AC Cord
RL801
RL802
TP805
To AC outlet
TP810
TP1001
CN1003
Pin9 of IC1001
jumper wire
TP1002
(component side)
Refer to "CHECKING THE POWER P.C.B." in "Troubleshooting Hints for Component Level Repair."
Note:
To turn on, solder a jumper between TP810 and TP805. Then, plug in AC Cord (snap sound).