Summary of Contents for HTP Everlast Elevate ELV055C2X055N
Page 1
California Proposition 65 Warning: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors in literature.
Page 2
AHJ. motion. Strapping shall be at points within the upper one-third NOTE: HTP reserves the right to modify product technical specifications (1/3) and lower one-third (1/3) of its vertical dimensions. At the lower point, a minimum distance of four (4) inches (102 mm) shall and components without prior notice.
Table of Contents Part 1 - General Safety Information A. When Servicing the Water Heating System B. Heater Water NOTE: Obey all local codes. Obtain all applicable permits before C. Freeze Protection installing the water heater. D. Water Temperature Adjustment NOTE: Install all system components and piping in such a manner Part 2 - Prepare the Water Heater that does not reduce the performance of any fire rated assembly.
This water heater is certified for indoor use only. DO NOT INSTALL Households with small children, disabled, or elderly persons may OUTDOORS. Outdoor installations ARE NOT covered by warranty. require a 120 F or lower temperature setting to prevent severe Failure to install the water heater indoors could result in property personal injury or death due to scalding.
RECOMMENDED SERVICE CLEARANCES 3" MIN. 8" MIN. 3" MIN. 3" MIN. LP-790-B 10/04/21 24" MIN. Figure 1 - Recommended Service Clearances • Water pH between 6.5 and 8.5 • pH levels below 6.5 can cause an increase in the rate of This water heater must not be located near flammable liquids corrosion.
Page 6
FRONT VIEW ANODE TOP VIEW MIXING VALVE TEMP/PRESSURE ASSEMBLY RELIEF VALVE ACCESS COVER COLD WATER INLET HOT WATER OUTLET ELEMENT ELECTRICAL ELECTRICAL ACCESS ACCESS THERMOSTAT PANEL PANEL ACCESS 45.00° 45.00° LP-790-A 10/04/21 TANK DRAIN Figure 2 - Dimensional Drawing - Staged Operation Specifications and Dimensions Water Temperature Ratings From Mixing Valve...
D. Anode Rod Part 3 - Piping This water heater is equipped with an anode rod. Anode rods are A. Plumbing sacrificial components that counteract water chemistry to minimize It is mandatory that all plumbing be done in accordance with federal, or eliminate tank corrosion.
Other methods of controlling thermal expansion are available. Check with the local water utility to determine if a check valve exists in the cold water inlet line. Contact your installing contractor, water To avoid water damage or scalding due to relief valve operation: supplier, or plumbing inspector for additional information regarding •...
G. Filling the Heater F. Scalding • Make certain that the drain valve is completely closed. • Open the shut-off valve in the cold water supply line. Mixing valves can reduce but do not eliminate the risk of scalding. • Open the hot water faucets to allow air to vent from the heater To avoid scalding: and piping.
Part 4 - Wiring Tank must be full of water before the power is turned on. Heating elements will be damaged if energized for even a short time while tank is dry. Failures due to “dry-firing” ARE NOT covered by warranty. This unit is factory wired to a junction box on top of the water heater for field wiring connection.
Part 5 - Installation Checklist Part 6 - Operation Water Heater Location Close to area of heated water demand Tank must be full of water before the power is turned on. Heating Indoors and protected from freezing elements will be damaged if energized for even a short time while temperatures tank is dry.
If heating elements need replacement, it is very important to use the same voltage, wattage, and construction. DO NOT replace heating element with a generic heating element. Only HTP heating elements are approved for use with this water heater. Failure to...
Page 13
Completely drain the water heater before removing and replacing a heating element or elements. Failure to do so will result in a leakage of water and property damage, and could possibly result in moderate to severe personal injury or death. Water drained from the water heater may be scalding hot.
hot water is needed again. Contact a qualified service contractor for Part 7 - Maintenance assistance if necessary. Considerations • To avoid electric shock, disconnect electrical supply before performing maintenance. Water drained from the water heater may be scalding hot. Take care •...
Page 15
To Inspect / Replace the Anode Draining the Water Heater STEP #1 - Drain the water heater following the procedure detailed in STEP #1 - Turn off power to the water heating system, preferably at this section. the circuit breaker. Completely drain the water heater before removing the anode.
Part 8 - Troubleshooting Problem Reason Remedy Manual disconnect switch turned off Turn switch on Blown fuse or circuit breaker tripped Replace fuse or reset breaker Shorted or improper wiring *Replace, repair, or rewire per detail Circuit overloaded *Provide adequate circuit to reduce load Grounded element or thermostat *Replace Manual Reset High Limit (ECO) open...
Part 9 - Replacement Parts ITEM # DESCRIPTION PART # FRONT COVER (FOR MIXING ASSY) 6060P-504 REAR COVER (FOR MIXING ASSY) 6060P-503 TEE FOR MIXING VALVE ASSY 6060P-506 FLEX HOSE FOR MIXING VALVE ASSY 6060P-507 MIXING VALVE 6060P-505 SEAL WASHER WITH FILTER SCREEN FOR MIXING VALVE (NOT SHOWN) 6060P-509 UNION FOR MIXING VALVE 6060P-508...
HTP reserves the right to issue a refund of the 9. Any failed components of the system not manufactured by HTP as part of published wholesale price available at the date of manufacture of the the water heater.
Page 19
During the claims process a product that must be replaced will be given a 18. Damages, malfunctions, or failures caused by abuse, accident, fire, flood, designation of either a) field scrap, or b) return to HTP. If the product must freeze, lightning, electrochemical reaction, acts of God and the like.
Customer Installation Record Form The following form should be completed by the qualified installer / service technician for you to keep as a record of the installation in case of a warranty claim. After reading the important notes at the bottom of the page, please also sign this document. Customer’s Name Date of Installation Installation Address...
Need help?
Do you have a question about the Everlast Elevate ELV055C2X055N and is the answer not in the manual?
Questions and answers