Page 1
OPERATION & INSTALLATION MANUAL BAPTISTRY HEATER AND CONTROL SYSTEM BES6000-HC & BES6000T-HC SERIES 5.5KW BES6005-HC & BES6005T-HC SERIES 11.0KW HYDROQUIP – 510A N. SHERIDAN ST. – CORONA, CA 92880 85-0130 REV.10 05/11...
Page 2
COMPONENT CONNECTIONS FLOAT SWITCH PLUMBING DIAGRAM PRESSURE SWITCH PLUMBING DIAGRAM SYSTEM INTERFACE MODULE PLUMBING TIPS EQUIPMENT DESCRIPTION START UP OPERATION PROBLEM SOLVING WARRANTY HYDROQUIP PART NUMBERS HQ PART NUMBER DESCRIPTION BES-6005-HC 11KW HEATER SYSTEM CONTROL BES-6000-HC 5.5KW HEATER SYSTEM SYSTEMS BES-6005T-HC...
Page 3
IMPORTANT SAFETY INSTRUCTIONS WHEN INSTALLING AND USING THIS EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ AND FOLLOW ALL INSTRUCTIONS INSTALLATION CONSIDERATIONS 1. A bonding lug has been provided on the outside of the equipment system electrical controls box.
Page 4
8. WARNING - TO REDUCE THE RISK OF INJURY A. The water in a tub should never exceed 100f (38c). Before entering the tub the user should measure the water temperature with an accurate thermometer, since the tolerance of water temperature-regulating devices may vary as much as +/- 5 f (3c).
Page 5
10. WARNING - the equipment system may be equipped with a ground fault circuit interrupter (GFCI), mounted on the electrical control box. This GFCI protects against electrical shock hazard by sensing electrical fault conditions and interrupting the electric power applied to the equipment system. Before each use of the tub the GFCI, if provided, should be tested in the following manner: Turn electric power on, Push the test button.
Page 6
PRODUCT FEATURES GROUND FAULT CIRCUIT INTERRUPTER – This device is required for portable tubs as specified in the national electrical code article 680. The GFCI is designed to protect against potential electrical shock hazard should a ground fault occur. THERMOSTAT - The thermostat regulates the water temperature of your tub. TIMECLOCK (Optional): Provides timer control over heating and filtering cycles PUMP RECEPTACLE –...
Page 7
INSTALLATION AND OPERATING CONSIDERATIONS The equipment control system must be protected from the elements by installing it in a weather-tight enclosure. The equipment should be installed so that there is safe access for servicing and routine maintenance procedures. The single-speed circulation pump must be installed below the water level unless it is a self-priming pump.
Page 8
240 VOLT INSTALLATION - Permanently Connected Units 1. Remove the faceplate from the control box to allow access to the input wiring. 2. Connect input wiring to the terminal block as shown below. A three wire electrical service plus ground is required for a 208-240-volt connection (line 1, line 2, neutral, and ground).
Page 12
SYSTEM INTERFACE MODULE SEE NEXT PAGE FOR IMPORTANT TIPS 85-0130 REV.10 5/11...
Page 13
PLUMBING AND AUTO-FILL TIPS PLUMBING TIPS: • MEASURE TWICE DRILL ONCE • DRY-FIT PLUMBING BEFORE HOLES ARE DRILLED • FLEXIBLE PVC SHOULD BE USED BETWEEN EQUIPMENT AND BAPTISTRY • ALWAYS USE COMPATIBLE ADHESIVES AND PRIMERS AUTO-FILL VALVE TIPS: • MAY BE INSTALLED ANYWHERE •...
Page 14
EQUIPMENT DESCRIPTION WIDTH = 30” HEIGTH = 13” DEPTH = 15” CONTROL BOX The control box contains all the electrical components necessary to operate your tub, it also contains the field wiring compartment. The System Interface Module (D RAIN/FILL ONTROL) Control plugs into the receptacle on the side of the control box. GROUND FAULT CIRCUIT INTERRUPTER (GFCI) The GFCI is designed to prov ide protection against potential electrical shock hazard...
Page 15
Test the GFCI as follows: 1. With the power on, push the test button; the reset button should pop out. aution - If the GFCI fails to operate in this manner, do not use the tub until a qualified service technician has corrected the problem.
Page 16
SYSTEM INTERFACE RECEPTACLE & MODULE Provides for operation of Auto-Fill & Auto-Drain options when S ystem Interface Module is stalled. TEM DIAGNOSTIC CENTER These indic provide real time diagnostics of the system. • HEATE R “ON” – Illuminated whenever the heater is activated •...
Page 17
OPERATION Operating considerations for BES standalone (option A): 1. For initial start up turn thermostat all the way down and fill tub. 2. Insure that tub has water above highest return and open bleed valve on face of pump to bleed air from system. .
Page 18
Operating considerations for BES with Remote Control Auto Fill/Drain (option D): 1. Insure that SYSTEM INTERFACE MODULE (DRAIN/FILL CONTROL) option is securely plugged into BES receptacle and that Auto-Drain valve cord is installed. Install one set of air tubing and air button from Remote Control on the On/Off air switch nipple and one set on the Fill/Drain air switch nipple.
Page 19
PROBLEM SOLVING Equipment system will not operate: 1. Make sure the Power Air Switch is turned “ON” 2. Check the Ground Fault Circuit Interrupter, if equipped, to see if the reset button has popped out. If it has, press reset button inward. If the GFCI trips repeatedly, contact a service technician to correct the problem.
Page 20
Pump seals, O-Rings, gaskets, are not covered by the Hydroquip, Inc. warranty during the first 12 months of the warranty period. Some items furnished by Hydroquip, Inc., such as spa-side controls, may be made by other manufacturers who might have longer warranty periods.
Page 21
_______________________________________________________________________ 510A SHERIDAN ST ~ CORONA, CA 92880 WARRANTY REGISTRATION PURCHASED BY: (PLEASE PRINT) Name _________________________________________________________________ Address _______________________________________________________________ City ___________________________________ State _________ Zip ______________ Telephone ( ) ____________________ DEALER: Name _________________________________________________________________ Address _______________________________________________________________ City __________________________________ State __________ Zip ______________ Telephone ( ) ____________________ Fax ( ) ____________________...
Need help?
Do you have a question about the BES6000-HC Series and is the answer not in the manual?