IMPORTANT NOTICE FOR USE IN HEALTHCARE ENVIRONMENTS: Dell products are not medical devices and are not listed under UL or IEC 60601 (or equivalent). As a result, they must not be used within 6 feet of a patient or in a manner that directly or indirectly contacts a patient 1.1 SAFETY: General Safety...
Page 3
pool or in a wet basement. Do not use AC powered equipment during an electrical storm. Battery powered devices may be used if all cables have been disconnected. Do not spill food or liquids on your equipment. Before you clean your equipment, disconnect it from the electrical outlet. Clean your device with a soft cloth dampened with water.
Be sure to grasp the plug, not the cable, when disconnecting equipment from an electric socket. If your equipment uses an AC adapter: Use only the Dell provided AC adapter approved for use with this device. Use of another AC adapter may cause a fire or explosion.
Page 6
See “NOTE" NOTE: For replacement of power cord, connectivity cable and external power supply (if applicable), contact Dell: 1. Go to https://www.dell.com/support. 2. Verify your country or region in the Choose A Country/Region drop-down menu at the bottom-right corner of the page.
NOTE: This “Disassembly and Assembly Procedures” is for EMEA only, not for other regions. Please note that Dell will deem warranty void if any disassembly is done on the monitors. Tools Required List the type and size of the tools that would typically can be used to disassemble the product to a point where components and materials requiring selective treatment can be removed.
5.1 Disassembly Procedures: Step Figure Remark Turn off power, S1. Before Unplug external disassembl cables from product Use a Philips-head screwdriver to remove 4 screws for S2. Remove remove the cover the cover hinge. hinge (No.1~4 screw size=M4x14; Torque=12±2kgf.cm) Use a Philips-head screwdriver to remove 20 screws for remove the Rear...
Page 13
1. Disconnect all of pins remove speakers. S4. Disconnect 2. Use a Philips-head all of the cable screwdriver to and remove the remove 4 screws speakers for remove the Speakers (No.1~4 screw size=Q4x10; Torque=8±1kgf.c Use a Philips-head screwdriver to S5. Remove the remove 4 screws for BKT and the key remove the BKT and...
Page 14
Use a Philips-head screwdriver to remove 8 screws for remove the Power board. (No.1~8 screw size=P3x4; Torque=4±1kgf.cm) Use a Philips-head S6. Remove the screwdriver to remove 6 screws for remove the Main &Power Board Main board. (No.1~6 screw size=D3x6 Torque=6±1kgf.cm ) Use a hex screwdriver to remove 4 screws for remove the Main board.
Page 15
Use a Philips-head screwdriver to remove 2 screws for S8. Remove remove DECO the DECO Bezel bezel (No.1~2 screw size=P3x4; Torque=4±1kgf.cm ) S9. Disconnect Disconnect the pin FFC cable Use a Philips-head screwdriver to remove 3 screws for remove S10. Remove the the BKT stand screw to remove (No.1~2 screw...
5.2 Assembly Procedures: Step Figure Remark S1. Assembly the Deco bezel The IR board and the IR board Use a Philips-head screwdriver to tighten 3 screws for S2. Tighten the stand AC SOCKET (No.1~2 screw ASS'Y size=M3x6 Torque=4±1kgf.cm No.3 screw size=M4x6 Torque=12±2kgf.cm) S3.
Page 17
Use finger to paste the Mylar S5. Paste the Use a Philips-head Mylar and screwdriver to screw 4 screw the screws for tighten the screws to BKT stand tighten the (No.1~4 screw BKT stand size=M4x8 Torque=6±1kgf.cm ) Use a Philips-head screwdriver to screw 8 screws for tiighten the Power board.
Page 18
Use a Philips-head screwdriver to screw 4 S7. Tighten the screws for tighten the BKT and the BKT and Key board key board (No.1~4 screw size=Q4x10 Torque= 4±1kgf.cm) 1. Connect all of the pins and assembly the speakers. 2. Use a Philips-head S8.