G.F.C.I. RECEPTACLE TEST
After starting the engine, check the G.F.C.I. for proper function-
ing by the following test procedure.
Push yellow TEST button, the red RESET button will pop
I
out exposing the word TRIP. Power is now off at the outlets
protected by the G.F.C.I., indicating that the device is func-
tioning properly.
I
If TRIP dose not appear when testing, do not use the gen-
erator. Call a qualified electrician.
I
To restore power, push RESET button.
WARNING
If the RESET button pops out during operation, stop the generator immedi-
ately and call a qualified electrician for checking generator and the appli-
ances.
(e) Turn the AC switch (no fuse breaker)
to on and check to see that the pilot
lamp is on.
(f) Turn on the switch of the appliance.
TIP
The AC switch (no-fuse breaker) turns off
automatically when the load exceeds the
generator rated output.
NOTICE
When the AC switch (no-fuse breaker)
turns off during operation, the genera-
tor is over loaded or the appliance is
defective. Stop the generator immedi-
ately, check the appliance and / or gen-
erator for overloading or detect and
have repaired as necessary by Yamaha
dealer or service shop.
A C
O N
O F F