8555-9201-000 / 0109
4.34
Alarm #48 - Water discharge
WATER DISCHARGE:
Overflow
Separation "Stop"
Alarm#48 Act. ENTER
Text display
Possible causes
Water content in product feed too
high.
Clean oil discharge pressure (product
discharge pressure) too high.
Filling water volume too small.
Product temperature too low.
Regulating ring too large.
Water pressure for hydraulics too high
or closing water pulse T06 too long.
Polyamide gasket in bowl top defec-
tive.
Gaskets in bowl defective.
Pressure switch PT2 defective.
Help text – information on the control
Step 1
E N T E R
Step 2
H E L P
F 1
Page 1
Page 2
Page 3
• Check product feed.
• Check clean oil discharge valve
(product discharge valve) V7.
• Check function V2 and filling water
volume.
• Check product temperature.
• Fit next smaller regulating ring.
• Check water pressure with open
valve and
• check T06.
• Check polyamide gasket in bowl
top.
• Check gaskets.
• Check pressure switch PT2.
Acknowledge fault
Press key >F1<
Help on alarm
Key >HOME< back
WATER DISCH. - OVERFLOW
Please check:
Clean oil disharge valve V7
Function V2
Water content in feed
Fillling water volume
Product temperature
Regulating ring
Polyamide gasket
Pressure switch PT2
back with ENTER
Mechanical Separation /
Action
->
->
GEA Westfalia Separator
79
Need help?
Do you have a question about the D 10 and is the answer not in the manual?
Questions and answers