TOPCON OS SERIES TOTAL STATION AND MAGNET FIELD
OS Series Backsight Setup Quick Guide
This Quick Guide is to show you how to setup and orientate the Topcon OS Series Total
Station using the Backsight Method.
It is important to make sure that the battery is seated in the instrument prior to setting
the Total Station up as the weight of the battery will affect the level of the instrument.
Step One: Positioning and Centring the Instrument with the Optical Plummet
1) Make sure the Tripod legs are spaced at equal intervals and the
Tripod head is roughly level.
Set the Tripod so the head is positioned over the Survey Point.
Make sure the Tripod feet are firmly fixed in the ground.
Tip: Set the height of the Tripod head at mid chest height to
ensure the telescope of the instrument is at eyelevel.
2) Place the Instrument on the Tripod head.
Supporting it with one hand, tighten the centring screw on the
bottom of the unit to make sure it is secured to the Tripod.
3) Looking through the optical plummet eyepiece, turn the optical
plummet eyepiece to focus on the reticule.
Turn the optical plummet focussing ring to focus on the survey
point.
Step Two: Levelling
1) Adjust the levelling foot screws to centre the
survey point in the optical plummet reticule.
2) Centre the bubble in the circular level by either shortening the
Tripod leg closest to the off-centre direction of the bubble or by
lengthening the Tripod leg farthest away from the off-centre
direction of the bubble. Adjust one more Tripod leg to centre
the bubble.
Turn the levelling foot screws while checking the circular level
until the bubble is centred in the centre circle.