1 Warning Caution: • Pb free solder has a higher melting point that standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a soldering iron with temperature control and adjust it to 750 ± 20°F (400 ± 10°C). In case of using high temperature solder- ing iron, please be careful not to heat too long.
4 Trial Operation (After Checking Troubleshooting Guide) 4.1. Assembly • Confirm if there is NO gap between Housing A and B by pinching the lead wires. • There is no dust or deformation on battery terminals. 4.2. Operation • Confirm if SWITCH turns ON and OFF normally. •...
5 Disassembly and Assembly Instructions 5.1. Remove the cartridge holder from the main unit. 5.2. Pull up the rack guide and remove 3 tapping screws.
Page 7
5.3. Pull the rack guide out forward. 5.4. Remove a connector cap.
Page 8
5.5. Remove housing B. 5.6. Remove the module.
Page 9
5.7. Remove the micro switch. 5.8. Remove 2 screws of the driving block.
Page 10
5.9. Release the spring for switch handle from the housing boss with radio pliers. * Spring for switch handle is strong. Be careful to remove it. 5.10. Take the driving block parts out from housing A.
Page 11
5.11. Remove the motor lead wires. NOTE: - Hold the terminal of lead wire with tweezers and touch the soldering iron tip to remove the lead wire. - type: Insulating type of soldering iron with less than 80W - procedure: Within 3 seconds with 400°C or less. - solder: Lead free type (Sn-3Ag-0.5Cu) 5.12.
8 Exploded View and Replacement Parts List Model No. : EY3610 Exploded View...
Page 15
Model No. : EY3610 Parts List Ref. Safety Part No. Part Name & Description Q'ty Remarks WEY3610K3078 HOUSING AB SET WEY3610K3657 CARTRIDGE CAP WEY3610S3717 CARTRIDGE HOLDER WEY3610K6118 TAPPING SCREW 11 TP4X14L WEY3610K0527 HOUSING CAP WEY2610L0207 WASHER WEY3610L0277 CONNECTOR CAP WEY3641K0488...