Operation Manual / TPL65-A32 / -A33 / -A36 + TPL69-A32 / -A33
5 Maintenance / 5.3 Cleaning the compressor during operation
5.3.2 Wet cleaning using external water-pressure vessel
Operating the water pres-
sure vessel
© Copyright 2020 . All rights reserved.
(XC3)
Operating state prerequisites for wet cleaning XC3
NOTICE
To be able to carry out a satisfactory cleaning process which has been
tested and is recommended by ABB Turbocharging, the following pre-
requisites must be fulfilled:
Engine load 50 ... 85%
u
Start of cleaning cycle in accordance with following description for
u
wet cleaning operation with XC3.
Operating procedure for compressor wet cleaning with XC3
The operating state prerequisites for compressor cleaning with XC3
u
must be fulfilled.
Remove sealing plug (X).
u
Fill vessel with required volume of clean water (see table Cleaning
u
parameters).
Screw in sealing plug (X).