Download Print this page

Sealey SA0615 Instruction Manual page 4

Compressor 6ltr direct drive 1.5hp

Advertisement

5.6.
iMPORtANt WARNiNG -
Air contaminants taken into the compressor will affect optimum performance. Example: Body filler dust or paint overspray will clog the
pump intake filter and may cause internal damage to pump/motor components. Please note that any parts damaged by any type of
contamination will not be covered by warranty.
6. tROUBLEShOOtiNG
FAULt
1a) Pressure drop in the tank.
1B) Pressure drop in the tank.
1c) Pressure drop in the tank.
2)
Pressure switch valve leaks when
compressor is idle.
3)
air leaks from tank body or tank welds.
4a) motor stops and will not restart.
4B) motor stops and will not restart.
5)
compressor stops and does not restart.
6a) compressor does not stop at max. pressure.
6B) compressor does not stop at max. pressure.
6c) compressor does not stop at max. pressure.
7)
compressor noisy with metallic knock.
8)
excessive moisture in discharged air.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMPORtANt: no liability is accepted for incorrect use of this product.
WARRANtY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
iNFORMAtiON: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
air leaks at connections.
air leaks from safety valve.
air leaks from cylinder head gasket.
non-return valve seal defective.
Internal corrosion caused by infrequent tank
draining or non permitted modifications to tank.
thermal cut out has operated.
Plug fuse has burnt out.
Pressure switch fault..
Head gasket or valve fault.
Bearing or piston damage.
High humidity environment.
recycle unwanted materials instead of disposing of them as waste. all tools, accessories and
packaging should be sorted, taken to a recycle centre and disposed of in a manner
which is compatible with the environment.
When the product is no longer required, it must be disposed of in an
environmentally protective way.
Sole UK distributor, Sealey Group,
Kempson Way, suffolk Business Park,
Bury st. edmunds, suffolk,
IP32 7ar
Original Language Version
CAUSE
motor failure.
filter clogged
Environmental Protection.
01284 757500
01284 703534
REMEdY
run compressor to max. pressure, switch off.
Brush soap solution over connections and look for
bubbles. tighten connections showing leaks.
If problem persists contact authorised service agent.
operate the safety valve manually. If valve
continues to leak when in the closed position it
should be replaced.
check tightness of head bolts. If leak continues
contact authorised service agent.
empty the air tank, remove the non-return valve
cap and clean, or if necessary, replace the seal.
tank could rupture or explode. cannot be repaired.
diSCONtiNUE USE iMMEdiAtELY.
allow to cool for 10 to 15 minutes before restarting.
replace fuse and restart unit. If repeat
occurs, contact authorised service agent.
contact authorised service agent..
contact authorised service agent.
clean or replace filter element.
contact authorised service agent.
contact authorised service agent.
drain tank after each use.
www.sealey.co.uk
Web
sales@sealey.co.uk
email
sa0615
Issue: 2 - 20/02/12

Advertisement

loading