Download Print this page

Sealey SAC3203B3PH Instructions For Use Manual

Compressor 200ltr belt drive 3.0hp 415v/3ph with front control panel

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE
PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL
INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
1.1
ELECTRICAL SAFETY.
 WARNING! It is the user's responsibility to read, understand and comply with the following:
You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and all
electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety
devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD
(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD together with portable products that are
plugged into an electrical supply not protected by an RCCB. If in doubt consult a professional electrician. You may obtain a Residual Current
Device by contacting your Sealey dealer. You must also read and understand the following instructions concerning electrical safety.
1.1.1
The Electricity At Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified
Electrician at least once a year, using a Portable Appliance Tester (PAT).
1.1.2
The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of the appliance, and the
safety of the appliance operator. If in any doubt about electrical safety, contact a qualified Electrician.
1.1.3
Ensure the insulation on all cables and the product itself is safe before connecting to the mains power supply. See 1.1.1. & 1.1.2.
above and use a Portable Appliance Tester (PAT).
1.1.4
Ensure that cables are always protected against short circuit and overload.
1.1.5
Regularly inspect power supply, leads, plugs and all electrical connections for wear and damage, especially power connections, to ensure that
none are loose.
1.1.6
Important: Ensure the voltage marked on the product is the same as the electrical power supply to be used and check that plugs are fitted with the correct
capacity fuse. If an electrical fuse blows, ensure it is replaced with an identical fuse type and rating.
1.1.7
DO NOT pull or carry the powered appliance by its power supply lead or output cables.
1.1.8
DO NOT pull power plugs from sockets by the power cable.
1.1.9
DO NOT use worn or damage leads, plugs or connections. Immediately replace or have repaired by a qualified Electrician. This
particular compressor is supplied without a mains plug. Follow the instructions below regarding the fitting of an appropriate plug.
1.2
MODEL SAC3203B3PH REQUIRES A 415V 3 PHASE SUPPLY AND MUST HAVE AN APPROPRIATE PLUG FITTED.
 WARNING! ELECTRICAL INSTALLATION OF THE COMPRESSOR TO A 3 PHASE 415VOLT SUPPLY MUST ONLY BE CARRIED OUT BY A
QUALIFIED ELECTRICIAN. Ensure the power supply cable is connected to the Earth.
1.2.1
This product must be fitted with a 3 phase plug wired as illustration in (fig.2), wired to an appropriately fused supply.
Connect GREEN/YELLOW wire to Earth 'E'
Connect BROWN wire to L1 Terminal.*
Connect BLACK wire to L2 Terminal.*
Connect the GREY wire to L3 Terminal.*
*NOTE: The cable core colours found in the mains cable on this compressor are consistent with Amendment 2 to 7671:2001. When completed,
check there are no bare wires, that all wires have been connected correctly and the cable restraint is tight.
 WARNING! IT IS ESSENTIAL TO OBSERVE ANTI-CLOCKWISE (fig.1) PULLEY DIRECTION ON INITIAL START UP. IF CLOCKWISE
OBSERVED, STOP IMMEDIATELY AND CONSULT A QUALIFIED ELECTRICIAN TO INVERT 2 PHASES.
DO NOT use this product with a standard extension cable. Only use ARMOURED extension cable
1.2.2
 IMPORTANT USER INFORMATION! Over-current protection of the power circuit is required in accordance with 7.2 of EN 60204-1:2006. The
supply disconnecting device to be in accordance with 5.3 of EN60204-1:2006. Ask a qualified electrician about compliance. The use of extension
leads to connect these compressors to the mains is not recommended.
Control Panel
(fig.7)
Ball valve
Receiver
Hose reel tidy
© Jack Sealey Limited
INSTRUCTIONS FOR:
COMPRESSOR 200LTR BELT DRIVE 3.0HP
415V/3PH WITH FRONT CONTROL PANEL
MODEL NO:
Switches
Pump
(fig.8)
(fig.5)
Motor
3~ph
Non return valve
Decompression
tube from switch
Swivel castor with brake
SAC3203B3PH
IMPORTANT!
Anti-clockwise
rotation
(label on guard)
see 1.2.1
From
pump
To receiver
2-Pneumatic
tyres 1.5bar
fig.1
Original Language Version
fig.2
(Grey) to L3
(Brown) to L1
(Black) to L2
SAC3203B3PH
'E' Earth
green/yellow
Mains
cable
Issue No: 1 - 27/10/14

Advertisement

loading

Summary of Contents for Sealey SAC3203B3PH

  • Page 1 SAC3203B3PH MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: General Safety

    Do not confuse this with the compressor displacement which is the air taken in by the compressor (‘air in’). ‘Air out’ is always less than ‘air in’ due to losses within the compressor. Original Language Version © Jack Sealey Limited SAC3203B3PH Issue No: 1 - 27/10/14...
  • Page 3 WARNING! DO NOT tamper with, or adjust, the pressure switch or safety pressure relief valve.  RECEIVER REGULATED PRESSURE PRESSURE Control Panel Gauges REGULATOR REGULATED fig.7 UNREGULATED SUPPLY SUPPLY Original Language Version © Jack Sealey Limited SAC3203B3PH Issue No: 1 - 27/10/14...
  • Page 4: Maintenance

    Recommended oil for compressors, suitable for room temperatures ranging from +5°C to +25°C. SEALEY CPO or equivalent SAE 40 compressor oil. Room temperature below +5°C: SAE 20 compressor oil. IMPORTANT WARNING - Air contaminants taken into the compressor will affect optimum performance.
  • Page 5: Troubleshooting

    Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500. NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
  • Page 6 Original Language Version SAC3203B3PH Issue No: 1 - 27/10/14 © Jack Sealey Limited...