A B B M E A S U R E M E N T & A N A LY T I C S | I N F O R M AT I O N | I N F 0 9/0 2 9 R E V. C
Endura AZ20
Oxygen monitor
1
Endura AZ20
oxygen monitor
This publication details the installation and
maintenance of an Endura AZ20 5μm/oil coalescing
filter regulator.
Introduction
5μm/Oil coalescing filter regulator
Measurement made easy
2
For more information
Further information is available from:
www.abb.com/analytical
or by scanning these codes:
Sales
Service

Advertisement

loading

Summary of Contents for ABB Endura AZ20

  • Page 1 5μm/Oil coalescing filter regulator Measurement made easy Introduction For more information Endura AZ20 oxygen monitor This publication details the installation and Further information is available from: maintenance of an Endura AZ20 5μm/oil coalescing www.abb.com/analytical filter regulator. or by scanning these codes: Sales Service...
  • Page 2 Endura AZ20 5µm/Oil Coalescing Filter Regulator 3 Identification 3 Identification The filter regulator can simultaneously supply up to 6 ABB Each unit contains 2 replaceable filter cartridges – see Table 3.2: zirconia-based in situ oxygen sensors with reference air at 0.3 to...
  • Page 3: Routine Checks

    Endura AZ20 Oxygen Systems Endura AZ20 5µm/Oil Coalescing Filter Regulator 4 Installation and Routine Checks 4 Installation and Routine Checks 4.1 Preparation 4.2.3 Manual Drain Valves Open the manual drain valves on the bottom of the filter To prepare the filter regulator for use: cartridges regularly to drain any contaminants and check air 1.
  • Page 4 Endura AZ20 Oxygen Systems Endura AZ20 5µm/Oil Coalescing Filter Regulator 5 Pressurizing the System 5 Pressurizing the System Referring to Fig. 3.1: 1. Ensure isolating valve A is in the closed position. 3-Way Ball Valve Shut-off / Vent Warning. The supply line pressure to the probe is Closed Position vented via the 3-way ball valve shut-off / vent.
  • Page 5: Replacing The Filter Cartridges

    Endura AZ20 Oxygen Systems Endura AZ20 5µm/Oil Coalescing Filter Regulator 6 Replacing the Filter Cartridges 6 Replacing the Filter Cartridges 6.1 Removing the Existing Filters Referring to Fig. 6.1: 1. Close isolating valve A. Warning. The supply line pressure to the probe is vented via the 3-way ball valve shut-off / vent.
  • Page 6 Endura AZ20 Oxygen Systems Endura AZ20 5µm/Oil Coalescing Filter Regulator 6 Replacing the Filter Cartridges 6.2 Fitting New Filters Referring to Fig. 6.2: 1. Free the oil coalescing filter A from the filter cartridge B by pressing the retaining tab C in and tilting the filter A to free it from one tab.
  • Page 7 We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.