Page 1
Non-Confidential Business Information (Non-CBI) Certification Test Report Hearth and Home Technologies Pellet-Fired Free Standing Room Heater Model: PP130-B Hearth and Home Technologies Prepared for: 352 Mountain House Road Halifax, PA 17032 OMNI-Test Laboratories, Inc. Prepared by: 13327 NE Airport Way...
Page 2
Model: PP 130-B Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 AUTHORIZED SIGNATORIES This report has been reviewed and approved by the following authorized signatories: Evaluation Decision: __________________________ Bruce Davis, Technician OMNI-Test Laboratories, Inc. Evaluation Decision: __________________________ Ken Morgan, Testing Manager OMNI-Test Laboratories, Inc.
SAMPLING PROCEDURE The PP130-B was tested in accordance with the U.S. EPA 40 CFR Part 60, Subpart AAA – Standards of Performance for New Residential Wood Heaters using ASTM E2515 and ASTM E2779. The fuel used for certification testing was Lignetics pellet fuel; this fuel was graded as Premium by the Pellet Fuels Institute and was produced at registered mill # 03208.
Model: PP 130-B Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 SUMMARY OF RESULTS The average particulate emission rate over the complete, integrated test run was measured to be 0.53 g/hr. The average particulate emission factor for the complete, integrated test run was measured to be 0.50 g/dry kg of fuel.
Model: PP 130-B Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 SUMMARY TABLES Table 1.1 – Particulate Emissions One-Hour Filter Integrated Total Emission Rate 0.96 0.53 (g/hr) Emission Factor 0.38 0.50 (g/dry kg) Table 1.2 – Efficiency and CO Burn Rate Segment Integrated Total...
Page 8
Model: PP 130-B Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Table 1.3 – Test Facility Conditions Initial Final Room Temperature (°F) Barometric Pressure 30.40 30.44 (in Hg) Air Velocity < 50 < 50 (ft/min) Induced Draft (in H2O) Table 1.4 –...
Page 9
Model: PP 130-B Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Table 1.5 – Dilution Tunnel and Flue Gas Measurements Average Dilution Tunnel Gas Measurements Average Segment Flue Draft Velocity Flow Rate Temperature (in H (ft/sec) (dscf/min) (°F) Integrated Total -0.034...
Model: PP 130-B Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Hearth and Home Technologies PP130-B PHOTOGRAPHS PP130-B Front PP130-B Back PP130-B Left PP130-B Control Knob 11 of 112...
Appliance Manufacturer: Hearth and Home Technologies Pellet Stove Model: PP130-B Type: Freestanding, air-circulating type, pellet-fired room heater. The PP130-B’s principle elements include a fuel hopper, mild steel firebox chamber, Stainless Steel burn pot, and electrical fuel feed, combustion air, and convection air supply systems.
Model: PP 130-B Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Section 5 Test Data by Run 13 of 112...
Page 14
Test Instruction Recommendations: PP130-B Created on/by: 03/20/18; C. Winslow Howe – HHT Design Engineer Purpose: To create repeatability in test protocol of the stove. Hopper Fuel: Hopper of the unit should be loaded up with a full 3 bags of fuel (Each bag weighing 40lb) Test Settings: Unit should be set up using a 6in flue and 115VAC power source, High: Dial should be set to 10 and the trim pot should be set to +4.
Page 15
1445 North Hwy, Colville, WA 99114; 800-234-2508 15 of 112...
Model: PP 130-B Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Run 1 16 of 112...
Page 17
OMNI-Test Laboratories, Inc Pellet Heater Conditioning Data - ASTM E2779 Manufacturer: Hearth & Home Model: PP130B Tracking No.: 2266 Project No.: 0135PS041E Test Date: March 2018 Operation Category: II - III - IV Elapsed Time Scale Stack (°F) (hours) Reading (lbs) 17 of 112 Control No.
Page 18
OMNI-Test Laboratories, Inc. Pellet Heater Preburn Data - ASTM E2779 Manufacturer: Hearth & Home Model: PP130B Tracking No.: 2266 PB Length: 60 min Project No.: 0135PS041E Recording Interval: 5 min Test Date: 3/26/2018 Averages: Elapsed Scale Weight Ambient Draft Stack (F) CO2 (%) CO (%) Time (min)
Page 19
OMNI-Test Laboratories, Inc. Pellet Heater Test Data - ASTM E2779 / ASTM E2515 Raw Data Run: Manufacturer: Hearth & Home High Burn End Time: PM Control Modules: 335,336 Model: PP130B Medium Burn End Time: Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 14.69 ft/sec.
Page 20
OMNI-Test Laboratories, Inc. Pellet Heater Test Data - ASTM E2779 / ASTM E2515 Raw Data Run: Manufacturer: Hearth & Home High Burn End Time: PM Control Modules: 335,336 Model: PP130B Medium Burn End Time: Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 14.69 ft/sec.
Page 21
OMNI-Test Laboratories, Inc. Pellet Heater Test Data - ASTM E2779 / ASTM E2515 Raw Data Run: Manufacturer: Hearth & Home High Burn End Time: PM Control Modules: 335,336 Model: PP130B Medium Burn End Time: Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 14.69 ft/sec.
Model: PP 130-B Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Section 4 Quality Assurance/Quality Control 30 of 112...
Page 31
This report is issued within the scope of OMNI’s accreditation. Accreditation certificates are available upon request. The manufacturing facilities and quality control system for the production of the PP130-B at Hearth and Home Technologies were evaluated to determine if sufficient to maintain conformance with OMNI’s requirements for product certification.
Page 34
Twin Ports Testing, Inc. 1301 North 3rd Street Superior, WI 54880 715-392-7114 800-373-2562 715-392-7163 www.twinportstesting.com Report No: USR:W218-0140-01 Issue No: Analytical Test Report OMNI-TEST LABORATORIES INC. Signed: Client: 13327 NE Airport Way Portland, OR 97230 Finance Department Stephen Sundeen Attention: Chemistry Laboratory Manager 180165 Date of Issue:...
Page 45
OMNI-Test Laboratories, Inc. Thermal Metering System Calibration Y Factor Previous Calibration Comparision Acceptable Manufacturer: APEX Date 7/18/2017 Deviation (5%) Deviation Model: XC-60-EP y Factor 0.981 0.04905 0.004 Acceptable Serial Number: 606001 Acceptance OMNI Tracking No.: OMNI-00335 Calibrated Orifice: FALSE Current Calibration Acceptable y Deviation 0.020 Average...
Page 46
OMNI-Test Laboratories, Inc. DIFFERENTIAL PRESSURE GAUGE CALIBRATION DATA SHEET Instrument to be calibrated: Pressure Transducer______________ Maximum Range: 0-2” WC ID Number: OMNI-00335 Calibration Instrument: Digital Manometer ID Number: OMNI-00395 Date: 1/17/2018 B. Davis This form is to be used only in conjunction with Standard Procedure C-SPC. Range of Digital Pressure Gauge...
Page 48
OMNI-Test Laboratories, Inc. Thermal Metering System Calibration Y Factor Previous Calibration Comparision Acceptable Manufacturer: APEX Date 7/18/2017 Deviation (5%) Deviation Model: XC-60-EP y Factor 0.984 0.0492 0.005 Acceptable Serial Number: 606002 Acceptance OMNI Tracking No.: OMNI-00336 Calibrated Orifice: FALSE Current Calibration Acceptable y Deviation 0.020 Average...
Page 49
OMNI-Test Laboratories, Inc. DIFFERENTIAL PRESSURE GAUGE CALIBRATION DATA SHEET Instrument to be calibrated: Pressure Transducer______________ Maximum Range: 0-2” WC ID Number: OMNI-00336 Calibration Instrument: Digital Manometer ID Number: OMNI-00395 Date: 1/17/2018 B. Davis This form is to be used only in conjunction with Standard Procedure C-SPC. Range of Digital Pressure Gauge...
Page 54
OMNI Track # OMNI-00594 Equipment Name/Description CAI ZRE-4 Gas Analyzer Equipment S/N: N5F0112 Comments CO2, O2, and dual range CO gas analyzer. Status Active, calibrate prior to use. ZRE-4 Part # Reference Standard: (Check 'X' for answer) Location of Equipment: Portable gas cart.
Model: PP 130-B Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Example Calculations 56 of 112...
Page 57
OMNI-Test Laboratories, Inc. Equations and Sample Calculations – ASTM E2779 & E2515 Manufacturer: Hearth & Home Model: PP70 Run: Category: [Integrated] Equations used to calculate the parameters listed below are described in this appendix. Sample calculations are provided for each equation. The raw data and printout results from a sample run are also provided for comparison to the sample calculations.
Page 58
OMNI-Test Laboratories, Inc. – Weight of test fuel burned during test run, dry basis, kg ASTM E2779 equation (1) = (M )(100/(100 + FM)) Where, average fuel moisture of test fuel, % dry basis weight of test fuel in hopper at start of test run, wet basis, kg weight of test fuel in hopper at end of test run, wet basis, kg Sample Calculation: 5.9 %...
Page 59
OMNI-Test Laboratories, Inc. – Weight of test fuel burned during test run segment i , dry basis, kg BSidb ASTM E2779 equation (2) = (MS )(100/(100 + FM)) BSidb Siwb ESiwb Where, weight of test fuel in hopper at start of test run segment i , wet basis, kg SSiwb weight of test fuel in hopper at end of test run segment i , wet basis, kg ESiwb...
Page 60
OMNI-Test Laboratories, Inc. BR – Average dry burn rate over full integrated test run, kg/hr ASTM E2779 equation (3) 60 M θ Where, = Total length of full intergrated test run, min θ Sample Calculation: = 5.57 = 360 θ 60 x 5.57 0.93 kg/hr...
Page 61
OMNI-Test Laboratories, Inc. – Average dry burn rate over test run segment i , kg/hr ASTM E2779 equation (4) 60 M BSidb θ Where, Total length of test run segment i , min θ Sample Calculation (from medium burn rate segment): 1.58 BSidb θ...
Page 62
OMNI-Test Laboratories, Inc. – Average gas velocity in the dilution tunnel, ft/sec ASTM E2515 equations (9) Where: strav , ASTM E2515 Equation (1) Adjustment factor for center of tunnel pitot tube placement, Fp = scent Dilution tunnel velocity calculated after the multi-point pitot traverse at the center, ft/sec scent...
Page 63
OMNI-Test Laboratories, Inc. – Average gas flow rate in dilution tunnel, dscf/hr ASTM E2515 equation (3) 3600 Where: 3600 Conversion from seconds to hours (ASTM method uses 60 to convert in minutes) Water vapor in gas stream, proportion by volume; assume 2% Cross sectional area of dilution tunnel, ft Standard absolute temperature, 528 °R Absolute average gas static pressure in diltuion tunnel, = P...
Page 64
OMNI-Test Laboratories, Inc. – Volume of Gas Sampled Corrected to Dry Standard Conditions, dscf m(std) ASTM E2515 equation (6) Where: 17.64 °R/in. Hg Volume of gas sample measured at the dry gas meter, dcf Dry gas meter calibration factor, dimensionless Barometric pressure at the testing site, in.
Page 65
OMNI-Test Laboratories, Inc. – Total Particulate Matter Collected, mg ASTM E2515 Equation (12) Where: mass of particulate matter from probe, mg mass of particulate matter from filters, mg mass of particulate matter from filter seals, mg Sample Calculation: Using equation for Train 1 (first hour): Using equation for Train 1 (remainder): Train 1 Aggregate =...
Page 66
OMNI-Test Laboratories, Inc. - Concentration of particulate matter in tunnel gas, dry basis, corrected to standard conditions, g/dscf ASTM E2515 equation (13) Where: Constant, 0.001 g/mg Total mass of particulate matter collected in the sampling train, mg Volume of gas sampled corrected to dry standard conditions, dscf m(std) Sample calculation: For Train 1:...
Page 67
OMNI-Test Laboratories, Inc. – Total Particulate Emissions, g ASTM E2515 equation (15) Where: Concentration of particulate matter in tunnel gas, g/dscf Concentration particulate matter room air, g/dscf Average dilution tunnel gas flow rate, dscf/hr Total time of test run, minutes θ...
Page 68
OMNI-Test Laboratories, Inc. PR - Proportional Rate Variation ASTM E2515 equation (16) Where: θ = Total sampling time, min θ = Length of recording interval, min = Volume of gas sample measured by the dry gas meter during the “ith”...
Page 69
OMNI-Test Laboratories, Inc. – Average particulate emissions for full integrated test run, g/hr ASTM E2779 equation (5) = 60 (E /θ) Where, = Tota particulate emissions, grams θ = Total length of full intergrated test run, min Sample Calculation: (Dual train average) = 2.96 g θ...
Page 70
OMNI-Test Laboratories, Inc. – Average particulate emission factor for full integrated test run, g/dry kg of fuel burned ASTM E2779 equation (6) Where, = Tota particulate emissions, grams = Weight of test fuel burned during test run, dry basis, kg Sample Calculation: (Dual train average) = 2.96 g...
Model: PP 130-B Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Section 5 Labeling & Owner’s Manual(s) 71 of 112...
Page 72
GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS. SERIAL NO. / NUMÉRO DU PP130-B Pellet Stove 1.5” x .375 Barcode Label HC079 room for .14 x .875” S/N...
Page 73
PP130 Pellet Stove Owner’s Manual WARNING! Please read this entire manual before installation and use of this pellet fuel-burning room Stove, and save for future reference. Failure to follow these instructions could result in property damage, bodily injury or even death. Contact local building or fire officials about restrictions and installation inspection requirements in your area.
Page 74
Indicates additional information to help you better understand your Stove and optimize its performance. NOTICE: Fire Risk PelPro disclaims any responsibility, and the warranty and agency listing will be voided, by the below actions. DO NOT: • Install or operate damaged Stove •...
Page 75
OUTSIDE MATERIAL. NORMAL DIM & INSIDE MATERIAL. OUTSIDE APEX ADD LOGO, UPDATE BACKGROUND COLORING LABEL OPERATION AND MAINTENANCE • Warranty Reference Materials......... 34 • Service Part List • Maintenance Log 75 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Getting Started Pallet Removal Pallet Removal There are bolts holding your PelPro Stove in place Visit pelprostoves.com on the pallet. To remove your Stove from the pallet: or scan the code: Using a 5/16 inch wrench, Loosen the three on each side of the Stove retaining bolts on remove the two bolts.
Stove. premium, low-ash pellets (<1%) less than 1.5” in length and avoid the dusty bits and pieces of pellets in the bottom of the bag. 77 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
• Sheet rock (drywall) • Carpet WARNING! Asphyxiation Risk. DO NOT INSTALL IN A SLEEPING ROOM. Consumes oxygen in the room. For Canada, the installation must conform to CAN/CSA-B365 78 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Page 79
Listed double wall flue connector to Class A Listed metal chimneys, or masonry chimneys meeting International Conference of Building Officials (ICBO) standards for solid fuel Stoves. Installation Video Visit pelprostoves.com or scan this code: 79 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Page 80
• The safest and preferred venting method is to extend the vent vertically through the roof or above the roof 80 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Side wall to Stove Corner Installation Straight back against wall Inches Walls to Stove Horizontal Installations Straight back against wall Inches Back wall to Stove Side wall to Stove 81 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
• Your Stove will not draft properly that can build up a concentration of fumes such as a stairwell, • Smoke may seep in your house covered breezeway, etc. • Excessive sooting 82 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Page 83
83 of 112 Minimum Vertical Vent for Three Elbows Minimum Vertical Vent for Three Elbows Minimum Vertical Vent for Two Elbows Minimum Vertical Vent for Two Elbows PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com ELBOWS THREE 90° ELBOWS Vent...
Page 84
_____ Pipe joints are secure and properly sealed • Enclosed space such as an attic, garage or crawl space. _____ Outside air kit installed properly _____ Confirm termination clearances 84 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Your Stove has a manufacture-set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise operate your Stove in a manner inconsistent with operation instructions in this manual. 85 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
• Alert children and adults to hazards of high temperatures • High temperatures may ignite clothing or other flammable materials • Keep clothing, furniture, draperies and other flammable materials away 86 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Page 87
WARNING! Shock hazard. • Plug directly into properly grounded 3 prong receptacle • Do NOT route cord under or in front of Stove • Recommend the use of a surge protector 87 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Page 88
Once primed, pellets will drop into the fire pot and the LED light will blink green as ignition starts. This process can take up to 20 minutes. CAUTION: During this process DO NOT: • Try to restart, manually add pellets or use any type of accelerant 88 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Page 89
After 30 minutes, turn the dial control to OFF and allow your Stove to cool completely. Once cooled, clean the fire pot. Your Stove is now ready to resume normal use. 89 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
15 minutes for stabilization before making another adjustment. Thermostat Your PelPro Stove comes with a built-in thermostat system that provides easy temperature adjustments. The Stove is not designed to use a remote control or external thermostat.
Turn dial control to OFF, let Stove completely cool and exhaust blower must be off. Now you can unplug Stove before servicing • Smoke spillage into room can occur if Stove is not cool before unplugging 91 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
What You’ll Need Cleaning tool Phillips head Safety glasses screwdriver Gloves Ceramic glass cleaner & Flue cleaning non-abrasive cloth brush Metal container Drop cloth Ash vacuum with lid 92 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
• Use non-abrasive cloth to remove residue Door Inspection • The gasket between the glass and firebox should be inspected periodically to make sure there is a good seal. 93 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Page 94
Zone • Vacuum any debris from the fan blades and Zone Zone blower housing Hopper • Empty hopper of any pellets • Vacuum any remaining pellets/debris from the hopper 94 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Page 95
Your chimney should be inspected once every few months during the heating season to determine if a creosote or soot buildup has occurred. If creosote or soot has accumulated, it should be removed to reduce the risk of a chimney fire. 95 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Zone • Check all connections and power plugs are secure Zone Zone Zone Zone • Visually inspect wires, blowers and power cord to find cause of possible short circuit 96 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
- Confirm all exhaust blower connections secure - Confirm the feed assembly and motor are clean and clear of debris • Confirm exhaust path is clean and clear (Zone 3) 97 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Page 98
Confirm exhaust path is clean and clear (Zone 3) • Examine Stove body (Zone 2) - Align igniter so it is properly placed and centered - Review fuel quality (see Pellet Fuel information on page 13) 98 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Page 99
Excessive fuel Excessive feeding/Feed Motor locked on Follow corrective action for feed motor does not turn spilling over the off. fire pot into the ash wells and/or excessive flame 99 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Page 100
Review the fuel being used. Dirty Failed Clean Installation Replace Installation configuration is tight allowing for limited air circulation around the Stove. Review the installation and move if necessary. 100 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Page 101
All replacement parts are covered for remainder of 90 Days original warranty period or 90 days, whichever is longer Additional terms and limitations apply. See page 28 for complete warranty information. 101 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
• Order replacement parts • Installation videos • Troubleshooting videos • Use and care videos • Manuals and more To contact a Consumer Care Specialist, email us at Info_PelPro@hearthnhome.com or call 877-427-3316. 102 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
• The Stove must be secured to the mobile home structure by bolting it to the floor through holes provided at bottom of your cast legs on your Stove. 103 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Listings and Certifications Glass Specifications This Stove is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact PelPro for replacement glass. Electrical Rating (On High) PP130-B: 120 VAC, 60 Hz, Start 2.6 Amps, Run 2.3 Amps BTU &...
Page 105
Warranty Coverage: Subject to the table below, HHT warrants to the owner of the PelPro Stove that the Stove will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered components are found to be defective in materials or workmanship during the applicable warranty period, HHT will replace the covered components.
Vacuum Hose, 5/32 ID 3 Ft SRV240-0450 Side Curtain, Right Hand SRV7086-153 Dial Control SRV7083-036 Wire Harness, Dial Control SRV7000-667 Hopper Switch SRV7000-612 See Following page for additional servcie parts 2/18 106 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Page 107
Feed Motor SRV7000-670 16.2 Feed Shaft Bushing Pkg of 2 7000-600/2 Power Cord 812-1180 Ambient Probe SRV7000-668 Exhaust Probe SRV7000-669 Wire Harness SRV7093-184 Wire Clip Pkg of 10 7000-400/10 107 of 112 PelPro Pellet Stove • 7104-171A • 4/20/18 pelprostoves.com...
Need help?
Do you have a question about the PP130-B and is the answer not in the manual?