[1] TROUBLESHOOTING TABLE
No power (front LED failure to light up) or no startup (front LED failure to turn from red to green)
Are the wire harnesses and other cables properly connected in 
the set?
Is there  the PS̲ON and PNL̲POW signal input at pins 
(14 ) and  (16 ) of P9601?
Are the DC/DC converter outputs and the output voltages along 
the control lines as specified?
1) D 1.5V  (IC9601)              
2) BU 3.3V (IC9602)
3) BU 1.1S (IC9603)
4) D 3.3V (IC9604)            
5) D 5.1V (IC9605)
6) PNL +12V (AO6405)
7) BU +5V (D9602 ) 
YES
YES
6 – 1
NO
Reconnect the wire harnesses and other cables properly in the 
set.
NO
Check the  PS̲ON  signal line PNL ̲POW signal line.
NO
Check the DC/DC converters and the control lines. Replace 
defective parts as required.