Download Print this page

Wiring The Touchpad To The Panel; Power Up And Bus Communication; Connecting The Touchpad For System Programming Only - GE ATP2100 Installation Instructions Manual

Advertisement

Power Up and
Bus
Communication
Programming
Connecting the
Touchpad for
System
Programming
Only
ATP2100 & ATP2600 Touchpads Installation Instructions

Wiring the Touchpad to the Panel

1. Remove panel AC and backup battery power.
2. Connect the touchpad +12V, A, B, and COM terminals to the matching panel terminals (Fig-
ure 6 for touchpad terminal identification).
3. Connect the hardwire contact wires to the touchpad COM and ZN terminals.
After making all wiring connections from the touchpad to the panel, you are ready to power up
the panel and verify correct communication between the touchpad and the panel. Upon power up,
the panel scans the bus for connected devices, assigns a unit number to each bus device, and auto-
matically learns the device ID number of each bus device.
1. Verify that all wiring between the panel and touchpad is correct.
2. Connect the panel battery and restore AC power. Alphanumeric touchpads briefly show
SCANNING BUS DEVICES, then display date and time.
3. Press STATUS. The touchpad should respond by beeping and displaying a status message.
If the system does not respond as described above, see the "Troubleshooting" section.
To program options for the newly installed touchpad (such as key beeps, learning the hardwire
contact input, or touchpad partition assignments) see the specific panel installation instructions.
For installations that don't include an alphanumeric touchpad as a permanent part of the system,
you can connect one for system programming to the Programming Touchpad Header on the
panel.
To do this you must first connect a Programming Touchpad Cable (60-791) to the touchpad wires
(see Programming Touchpad Cable Installation Instructions—466-1604, included with the
cable). Then, use the appropriate procedure for connecting the touchpad.
To connect a programming touchpad to a Concord
panel with software version 2.0 or later:
1. With the panel powered up, connect the cable to the Programming Touchpad Header (Figure
7).
Figure 7. Connecting a Programming Touchpad—Concord Express Shown, Concord Similar
+12V
A
COM ZN
B
Figure 6. Touchpad Wiring Connections
Express, Concord, or Concord Ultra
3

Advertisement

loading

This manual is also suitable for:

Atp260060-98460-985