Download Print this page

Mitsubishi Electric FR-F840-00023 Installation Manuallines page 38

Hide thumbs Also See for FR-F840-00023:

Advertisement

BASIC OPERATION
Parameter Name
Stall prevention level
149
at 10V input
Output current
150
detection level
Output current
151
detection signal
delay time
Zero current
152
detection level
Zero current
153
detection time
Voltage reduction
154
selection during stall
prevention operation
RT signal function
155
validity condition
selection
Stall prevention
156
operation selection
OL signal output
157
timer
AM terminal function
158
selection
Automatic switch-
over frequency range
159
from bypass to
inverter operation
User group read
160
selection
Simple
Simple
Simple
Frequency setting/
161
key lock operation
selection
Automatic restart
after instantaneous
162
power failure
selection
First cushion time for
163
restart
First cushion voltage
164
for restart
Stall prevention
165
operation level for
restart
Output current
166
detection signal
retention time
Output current
167
detection operation
selection
168
Parameter for manufacturer setting.
Do not set.
169
Watt-hour meter
170
clear
Operation hour
171
meter clear
User group
172
registered display/
batch clear
*9
Differs according to types. (FM type/CA type)
*11
The setting is available for the FR-F800-E or when a compatible plug-in option is installed.
*12
Differs according to model types (standard model, separated converter type).
*13
Setting available for standard models only.
32
Initial
Setting Range
Value
150/
0 to 400%
*9
120%
120/
0 to 400%
*9
110%
0s
0 to 10s
5%
0 to 400%
0.5s
0 to 10s
1
0, 1, 10, 11
0
0, 10
0 to 31, 100,
0
101
0s
0 to 25s, 9999
1 to 3, 5 to 14,
17, 18, 21, 24,
34, 50, 52 to 54,
1
61, 62, 67, 69,
70, 86 to 96, 98
9999
0 to 10Hz, 9999
*9
0, 1, 9999
9999/0
0
0, 1, 10, 11
0
0 to 3, 10 to 13
0s
0 to 20s
0%
0 to 100%
120/110%
0 to 400%
*9
0.1s
0 to 10s, 9999
0
0, 1, 10, 11
9999
0, 10, 9999
9999
0, 9999
0
9999, (0 to 16)
Parameter Name
User group
173
registration
174
User group clear
STF terminal
178
function selection
STR terminal
179
function selection
RL terminal function
180
selection
RM terminal function
181
selection
RH terminal function
182
selection
RT terminal function
183
selection
AU terminal function
184
selection
JOG terminal
185
function selection
CS terminal function
186
selection
MRS terminal
187
function selection
STOP terminal
188
function selection
RES terminal
189
function selection
RUN terminal
190
function selection
SU terminal function
191
selection
IPF terminal function
192
selection
OL terminal function
193
selection
FU terminal function
194
selection
Initial
Setting Range
Value
9999
0 to 1999, 9999
9999
0 to 1999, 9999
0 to 8, 10 to 14,
16, 18, 24, 25,
28, 37 to 40,
46 to 48,50, 51,
60, 62, 64 to 67,
60
*13
70 to 71
,
72 to 73,
*13
77 to 81, 84
,
94 to 98, 9999
0 to 8, 10 to 14,
16, 18, 24, 25,
28, 37 to 40,
46 to 48,50, 51,
61, 62, 64 to 67,
61
*13
70 to 71
,
72 to 73,
*13
77 to 81, 84
,
94 to 98, 9999
0
1
2
0 to 8, 10 to 14,
3
16, 18, 24, 25,
28, 37 to 40,
4
46 to 48,50, 51,
62, 64 to 67,
*13
70 to 71
,
5
72 to 73,
*13
77 to 81, 84
,
9999
94 to 98, 9999
*12
24/10
25
62
*13
0, 1, 2
, 3 to 5,
0
7, 8, 10 to 19, 25,
26, 35, 39 to 42,
45 to 54, 57, 64,
1
*13
*13
65
, 66
, 67,
68, 70 to 80, 82,
*12
*13
2/9999
85
, 90 to 96,
*13
98 to 101, 102
,
103 to 105, 107,
3
108, 110 to 116,
125,126, 135,
139 to 142, 145
to 154, 157, 164,
*13
*13
165
, 166
,
167, 168, 170 to
*13
180, 182, 185
,
190 to 196,198
to 208, 211 to
4
213, 215, 217 to
220, 226, 228 to
*11
230, 242
, 300
to 308, 311 to
313, 315, 317 to
320, 326, 328 to
*11
330, 342
,
9999

Advertisement

loading