4. LIST OF ADJUSTMENT PROCESS MODE MENU
(*) The page number will be changed at the running change. For the number to be changed, please check ( ).
PAGE(*)
PAGE
NUMBER
TITLE
1/7
INFO
INIT
2/7
3/7
WB ADJ
ETC
4/7
5/7
PANEL
ITEM
Main version
SVN Number
PANEL Version
TEMP SENSOR
NORMALSTANDBT CAUSE
ERROR STANDBY CAUSE
Factory Init
Panel Setting
Public Mode
Operation Acutime
RESET
IN POINT LOW
IN POINT HIGH
R LEVEL LOW
G LEVEL LOW
B LEVEL LOW
R LEVEL HIGH
G LEVEL HIGH
B LEVEL HIGH
R LEVEL MAX
G LEVEL MAX
B LEVEL MAX
ADJ DATA STORE
RESET ADJUSTMENT
EEP CLEAR
STANDBYCAUSE RESET
DESTINATION
L ERR RESET
L ERR STOP
TEMP CAUTION
TEMP SHUTDOWN
VCOM ADJ
TCON TEST PATTERN
TEST PATTERN
4T-B70CJ1 TROUBLE SHOOTING
Main Software Version.
(Detail) Eel_ATSC_Pack**_v*.**(****)
V*.** : SW version
(****) : Boot version
Don't care
Don't care
TEMP sensor (Thermistor) value every 200msec.
Cause of last Stand-By Operation.
(Detail) NONE / Remote control / Keyboard / RS232C / No signal off /
No operation off / Sleep timer
Cause of last (up to 5) Error Protection Stand-By Operation and TIME.
(If the times have more than 5, the latest information should display at the
bottom.)
Initialization for factory settings
LCD panel module information
Change of Enable/Disable access to Public Setting MENU.
Accumulate Time of TV-SET Operation.
Reset the Accumulate Time of TV-SET Operation.
Standard value Low (In AV MODE : STANDARD,MOVIE,GAME,USER,PC)
Standard value High
WB adjustment Point Low ,R adjustment value
WB adjustment Point Low ,G adjustment value
WB adjustment Point Low ,B adjustment value
WB adjustment Point High ,R adjustment value
WB adjustment Point High ,G adjustment value
WB adjustment Point High ,B adjustment value
WB adjustment Point Max ,R adjustment value
WB adjustment Point Max ,G adjustment value
WB adjustment Point Max ,B adjustment value
Update and Store all of gamma register value
Reset default value above items and Adj-Flag
Clear the EEPROM data to 0xFF.
Clear the STANDBY CAUSE history.
Indicate the kind of Factory-Initialization command
Indicate the count of Lamp Error Protection. And Reset the counter
Lamp Error protection flag (Enable/Disable)
Setting for threshold level of High-Temp. caution (THRS1)
Setting for threshold level of High-Temp. protection (THRS2)
V-COM adjustment value
Display the T-CON Test Pattern
Display the Test Pattern.
4 - 18
FUNCTION

Hide quick links: