Statements and instructions set forth herein are based upon the best information and practices known to Evoqua Water Technologies, but it should not be assumed that every acceptable safety procedure is contained herein. Of necessity this company cannot guarantee that actions in accordance with such statements and instructions will result in the complete elimination of hazards and it assumes no liability for accidents that may occur.
Page 4
V10K V-NOTCH CHLORINATOR INTRODUCTION This manual includes a description of the Evoqua Water Technologies V10K Type V-Notch Gas Feeder (Chlorine) with installation, operating, and maintenance procedures. This equipment is designed to control and meter the flow of gas under vacuum and to mix the gas with water.
Page 5
DO NOT USE HYDROCARBONS OR ALCOHOLS BECAUSE RESIDUAL SOLVENT MAY REACT WITH THE GAS. SOL- VENTS CAN PRODUCE SERIOUS PHYSIOLOGICAL EFFECTS UNLESS USED IN STRICTEST COMPLIANCE WITH THE SOLVENT MANUFACTURER’S SAFETY RECOMMENDATIONS. WHEN USING HYDROCHLORIC ACID, OBSERVE ALL SAFETY PRECAUTIONS RECOMMENDED BY THE ACID MANU- FACTURER/SUPPLIER. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612 SP-1...
Page 6
If such a change apparently has been made in your equipment and does not appear to be reflected in your instruction book, contact your local Evoqua Water Technologies sales office for information.
Page 7
WITH A RUBBER STOPPER OR EQUIVALENT TO PREVENT THE ENTRANCE OF MOISTURE. MOISTURE MUST BE EXCLUDED FROM ANY PART OF THE EQUIPMENT THAT IS NORMALLY EXPOSED TO DRY CHLORINE ONLY. WHILE DRY CHLORINE IS NON-CORROSIVE, MOIST CHLORINE IS EXTREMELY CORROSIVE TO COMMON METALS, SUCH AS BRASS OR STEEL. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612 1.010-40...
Page 8
Phone: (800) 524-6324 NOTE Minor part number changes may be incorporated into Evoqua Water Technologies products from time to time that are not immediately reflected in the instruction book. If such a change apparently has been made in your equipment and does not appear to be reflected in your instruction book, contact your local Evoqua Water Technologies sales office for information.
Page 9
Preventive maintenance kits may be ordered directly from the company that supplied your equip- ment, or they may be ordered directly from Evoqua Water Technologies. For ordering numbers, refer to the parts list at the rear of this book.
Page 10
Date Performed *NOTE: This is the recommended cycle. Your local operating conditions may call for more fre- quent preventive maintenance. PROTECT YOUR EQUIPMENT INVESTMENT MINIMIZE DOWNTIME ORDER A PREVENTIVE MAINTENANCE KIT NOW ... KEEP ONE ON HAND WT.025.100.001.UA.IM.0614 EVOQUA W3T109612 1.010-13B...
Page 11
Direct any questions concerning this equipment that are not answered in the instruction book to the Reseller from whom the equipment was purchased. If the equipment was purchased directly from Evoqua Water Tech- nologies, Colorado Springs, CO contact the office indicated below.
Manual: 20 to 1 for any one rotameter Automatic: 10 to 1 for any one V-notch plug Airborne Noise Emission: Does not exceed 70dB (A) Dimensions: See mounting drawing Weight: Manual wall mount: 5.5 lb. (2.5 kg.) Automatic panel mount: 20 lb. (9 kg.) WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 24
Installation Piping - 2” Injector Connections for Prime and Flush Operation ....25.100.006.122 Connections for Intermittent Start-Stop Operation ..............25.100.006.142 Connections for Intermittent Start-Stop Operation With Injector Suction Shut-Off Unit ......25.100.006.152 Connections for Manual Suction Shut-Off Unit ..25.100.06.131 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 25
• Both in operation and in storage give the container the protection measures described in the Gas Handling Manual (at the rear of this book). WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 26
Remove the cover of the control unit. The control unit has three holes for mounting. c. Level the control unit (rotameter) before final tightening. d. After the control unit has been leveled and tightened, replace cover. Figure 2.1 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 27
If the injector discharges horizontally, the diaphragm should be in a hori- zontal plane above the nozzle and tailway. b. If the injector discharges vertically upward, the connection to the control unit should be vertically upward. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 28
In all cases, the tubing from the control unit should enter the injector from above. d. For one-inch fixed throat injectors, a rigid PVC pipe or Evoqua Water Tech- nologies solution hose is required between the injector discharge and the point of application.
Page 29
(or next fitting in the assembly) until the orientation is proper with the gas inlet side on top or most accessible face. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 30
Turn the adjusting screw clockwise (up) or counterclockwise (down) until the highest vacuum is obtained. To adjust the injector for minimum water usage, start the gas feeder and set the feed WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 31
(valves, pump impellers, etc.) caused by diffusion of solution during shut- down periods. It is recommended that all solution delivery lines be fitted with a suitable valve and drain pipe to enable any pressure buildup to be safely released prior to maintenance work. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 32
Rigid PVC pipe or Evoqua Water Technologies solution hose is required be- tween the injector discharge and the point of application. The size depends on the size of the throat and tailway used in the injector. Solution hose may be connected directly to the injector tailway.
Page 33
See the INSTALLATION WIRING diagrams for the electronic controller connections in the separate instruction book. NOTE: Field wiring must conform to local electrical codes. Vacuum Alarm Switch If a vacuum alarm switch has been ordered, see separate Instruction Book. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 34
For each tubing end to be connected, make a clean square cut at the end of the tubing using a sharp knife, then proceed as appropriate: • For 1/4” x 3/8” tubing and the Evoqua Water Technologies PVC tubing connector: a. Slip a union nut over the tubing, threaded end facing the tubing end.
Page 35
TERMINATE THE VENT LINE AT A LOCATION ROUTINELY USED BY PER- SONNEL, SUCH AS WORK AREAS OR PATHWAYS NOR NEAR WINDOW OR VENTILATION SYSTEM INTAKES. c. From the union on the left of the control unit below the rotameter to the vacuum regulator. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 36
1-1/4" 1-1/2" 2" 3" 4" JOINTS PER PINT OF CEMENT CEMENT AVAILABLE FROM EVOQUA WATER TECHNOLOGIES IN PINT CANS (U24647). ALSO AVAILABLE COMMERCIALLY IN PINT, QUART AND GALLON CANS. PVC PIPE - INSTALLATION Fabrication and Installation 50.830.110.011 ISSUE 14 6-14 WT.025.100.001.UA.IM.0614...
Page 37
V10K V-NOTCH CHLORINATOR NOTE: ACCESSORY ITEM FURNISHED ONLY IF SPECIFICALLY LISTED IN QUOTATION. NOT FURNISHED BY EVOQUA WATER TECHNOLOGIES. 200PPD AND 500PPD V10k V-NOTCH GAS FEEDER - TYPICAL INSTALLATION 25.100.110.030 ISSUE 2 6-14 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 38
V10K V-NOTCH CHLORINATOR NOTE: ACCESSORY ITEM FURNISHED ONLY IF SPECIFICALLY LISTED IN QUOTATION. NOT FURNISHED BY EVOQUA WATER TECHNOLOGIES. 200PPD AND 500PPD AUTOMATIC V10k V-NOTCH PANEL - TYPICAL INSTALLATION 25.100.110.040 ISSUE 2 6-14 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 39
V10K V-NOTCH CHLORINATOR Wallace & Tiernan Products NOTE: ACCESSORY ITEM FURNISHED ONLY IF SPECIFICALLY LISTED IN QUOTATION. NOT FURNISHED BY EVOQUA WATER TECHNOLOGIES. 750PPD V10k V-NOTCH GAS FEEDER - TYPICAL INSTALLATION Manual Arrangement 25.100.110.050 ISSUE 1 6-14 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 40
V10K V-NOTCH CHLORINATOR NOTE: ACCESSORY ITEM FURNISHED ONLY IF SPECIFICALLY LISTED IN QUOTATION. NOT FURNISHED BY EVOQUA WATER TECHNOLOGIES. 750PPD AUTOMATIC V10k V-NOTCH PANEL - TYPICAL INSTALLATION 25.100.110.060 ISSUE 2 6-14 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 47
Changing Gas Supply Containers ........3.6 Illustrations Flow Diagram 200-500PPD Units ............25.100.185.015 750PPD Units ............. 25.100.185.020 2” Injector Manually Operated ..........25.100.181.011 Intermittent Start-Stop Operation ......25.100.181.021 Prime and Flush Operation ........25.100.181.031 Block Diagram - Electric Positioner........ 40.300.180.010 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 48
3.1.2 Theory of Operation The Evoqua Water Technologies V10k Gas Feeder is designed to control and indicate the rate of flow of gas under vacuum. It provides a simple means of setting the feed rate at any value within the range of the machine and mixes the gas with water.
Page 49
3.2.1 Physical Check a. Ensure that the gas supply lines from the cylinder or ton containers are securely connected and that all valves in the system are closed. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 50
(1) The V-notch extension chamber through which the V-notch plug travels. (2) The gasket at the bottom of the differential regulating valve and pres- sure relief valve. (3) The connections of both ends of the plastic tubing on the gas discharge line to the injector. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 51
Adjust the gas feed rate as desired. Rotation of the knob counterclockwise increases the feed rate. e. Check that the vacuum gauge pointer is in the green sector. If there are two vacuum regulators, turn on the gas supply at the second supply container valve and vacuum regulator. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 52
Automatic Operation Refer to the automatic controller book for automatic operation. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 53
(M) through solenoid (N) and the three-way valve to chamber (C). When the solenoid is de-energized, the water supply is cut off and the exhaust port is opened permitting pressure chamber (C) to be relieved to waste. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 54
Operation of the solenoids is usually accomplished by a program clock in which each portion of the cycle may be fixed by setting adjustable cams. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 55
V10K V-NOTCH CHLORINATOR NOTE: SHOWN IN STANDBY POSITION. 200 - 500PPD UNITS SERIES V10k V-NOTCH GAS FEEDER - FLOW DIAGRAM 25.100.185.015 ISSUE 0 7-05 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 56
STANDBY GAS MANIFOLD STANDARD VACUUM 3000 PPD VACUUM REGULATOR REGULATOR 510 VACUUM REGLUATOR NOTE: SHOWN IN STANDBY POSITION. 750PPD UNITS 25.100.185.020 SERIES V10k V-NOTCH GAS FEEDER ISSUE 0 7/05 - FLOW DIAGRAM 25.100.185.020 ISSUE 0 7-05 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 62
Pressure Relief Valve ............. 4.8.4 Troubleshooting ..............4.9 Warning/Caution Summary Pages ........2 Pages Illustrations Service - Installation and Removal of Rotameter ..25.100.150.020 Service - Automatic Control Unit ........25.200.150.010 Operation - Manual Operation ........40.300.170.010 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 63
MENT DAMAGE, DO NOT TOLERATE ANY LEAKS. THEY ALWAYS GET PROGRESSIVELY WORSE AND MUST BE CORRECTED PROMPTLY. NOTE: For leak testing, use Evoqua Water Technologies U409 or Commercial 26° Baume’ aqua ammonia. Household ammonia is not strong enough. For checking leakage of chlorine gas at joints, valves etc., hold the moistened dauber of the ammonia close to the joint or suspected leakage area.
Page 64
Check for physical damage to removed parts (chipped, cracked, damaged threads, etc.). Replace damaged parts. b. Discard and replace all removed O-rings, seals and gaskets. c. Check diaphragm for chafing or cracking. Replace damaged diaphragms. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 65
PROTECT YOUR EQUIPMENT INVESTMENT MINIMIZE DOWNTIME REORDER A PREVENTIVE MAINTENANCE KIT NOW KEEP ONE ON HAND NOTE: If the gas feeder is used seasonally or after a long-term shut-down, the preventive maintenance should be performed prior to startup. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 66
10 minutes. Note if any water appears at the outer end of the connection fitting on the injector. If any water is seen, service the injector diaphragm check and poppet check. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 67
Most of the residue which accumulates can usually be removed with warm water and a detergent. Rubber parts should be cleaned only with warm water and a detergent. WARNING: TO PREVENT POSSIBLE SEVERE PERSONAL INJURY OR EQUIPMENT DAMAGE, DO NOT USE WOOD ALCOHOL, ETHER, PETROL OR PETROLEUM DISTILLATES. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 68
To clean the float pour about an inch of warm to hot (130-150°F) water into the cup containing the float. Grasp the float with tweezers and shake it side to side while submerged for a few seconds. Release the float and pick WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 69
Automatic: Put electric actuator in manual position as described in electric actuator book. Rotate knob to lower actuator shaft down as far as possible. Unscrew the clamping nut and push the V-notch up. Unscrew the V-notch plug chamber. Unscrew the V-notch plug. Reassemble in reverse order. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 70
As this opening is enlarged, the water velocity decreases and the vacuum developed also decreased. Deposits may be removed by immersing the throats in dilute (10%) hydrochloric acid, known commercially as muriatic acid. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 71
Using a blunt tool, remove the O-ring from the valve seat (diaphragm clamping screw). Discard the O-ring. g. Reassemble the valve stem to the upper body and replace the valve seat O-ring and diaphragm clamping O-ring (outer) prior to assembling the injector body union nut. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 72
If the spherical surface is indented, worn, eroded, or scratched, replace valve stem. WARNING:TO AVOID POSSIBLE SEVERE PERSONAL INJURY OR EQUIP- MENT DAMAGE WHEN USING HYDROCHLORIC ACID, OBSERVE ALL SAFETY PRECAUTIONS RECOMMENDED BY THE ACID MANUFAC- TURER/SUPPLIER. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 73
Cleaning 1” Fixed Throat Injector (Standard) (See Dwg. 25.200.002.030) • Cleaning Injector Unit Diaphragm Backcheck a. Shut off injector operating water. b. Take steps to prevent water from the point of application, flowing back toward the injector. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 74
O-ring and diaphragm clamping O-ring (outer). Bolt the flange in place with six bolts. • Cleaning Poppet Check a. To clean poppet check unscrew adapter and remove O-ring. Discard the O-ring. b. Remove poppet and remove O-ring. Discard the O-ring. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 75
Press in the new seat using a round rod or plastic tube (16 mm) with a flat front. Place the poppet into the guide and screw in the clamping nut with the assembled parts. m. Screw in the plug. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 76
The Evoqua Water Technologies sales office or the dealer from whom you purchased the equipment can provide the preventive maintenance kits or overhaul service.
Page 77
Clean the residue that accumulates on the valve seat with warm water and a detergent. Pipe cleaners or soft brushes may facilitate cleaning but wire brushes, scrapers and the like should be avoided as they will damage the parts. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 78
Wipe a thin film of Halocarbon grease onto all O-rings and gaskets before reassembling. c. Reassemble in the reverse order of disassembly. Troubleshooting The following troubleshooting table is provided for determining and correcting most common troubles. WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 84
HAZARDOUS GAS IS PRESENT IN THIS EQUIPMENT DURING NOR- MAL OPERATION. TO AVOID POSSIBLE SEVERE PERSONAL INJURY OR DAMAGE TO THE EQUIPMENT, READ THE EVOQUA WATER TECHNOLOGIES INSTRUCTION BOOK AND THE APPROPRIATE GAS MANUAL BEFORE CONNECTING THIS EQUIPMENT TO A SUPPLY OF GAS.
Page 85
8. The Evoqua Water Technologies instruction book provided with this equipment furnishes complete and detailed in- structions for its installation, operation and maintenance and must be referred to for that detailed information.
Page 86
---------------------------------------------------------------------------------------------------- P4373: PULL OUT STEM TO FULL LENGTH OF CHAIN BEFORE CLOSING VALVE. ---------------------------------------------------------------------------------------------------- AFM4743: FOR CHLORINE, SULFUR DIOXIDE, AMMONIA OR CARBON DIOXIDE USE ONLY. ---------------------------------------------------------------------------------------------------- ADH4733: FOR CHLORINE, SULFUR DIOXIDE OR CARBON DIOXIDE USE ONLY. ---------------------------------------------------------------------------------------------------- WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 87
V10K V-NOTCH CHLORINATOR INSTALLATION AND REMOVAL OF ROTAMETER - SERVICE Used In V10k V-Notch Gas Feeders 25.100.150.020 ISSUE 0 7-05 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 88
POSITION RACK AT ZERO FEED POSITION. AUTOMATIC CONTROL UNIT - SERVICE G. ADJUST BALL AND SCREW FOR CORRECT ALIGN- Zero Position of Plug MENT BETWEEN THE ACTUATOR AND THE PLUG. 25.200.150.010 H. ATTACH THE NUT AND TIGHTEN. ISSUE 0 10-95 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 89
ADJUST THE GAS FEED RATE AS DESIRED BY ROTATING THE KNOB. C. TO RETURN TO AUTOMATIC CONTROL, PRESS THE KNOB AND ROTATE THE KNOB SLIGHTLY UNTIL GEAR TEETH ENGAGE. INSTRUCTIONS FOR MANUAL OPERATION - OPERATION Positioner 40.300.170.010 ISSUE 0 10-95 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 91
And 3/4” Or 1” Main Connections ......50.845.06.032 2” Injector, With Manually Operated Plug Shut-Off ............25.052.001.051A&B 2” Injector, With Pressure-Operated Plug Shut-Off ............25.052.001.046A&B U19315 Injector Shut-Off Unit ........25.100.06.111 2” Main Connection, With Corporation Cock For 1-1/2” Or 2” Hose ..........50.845.002.022 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 92
V10K V-NOTCH CHLORINATOR NOTE: FOR PARTS LIST, SEE DWG. 25.100.000.040B. 5" AND 10" LOW CAPACITY (200PPD) 5" AND 10" HIGH CAPACITY(750PPD) WALL-MOUNTED CONTROL UNIT - PARTS Manual Arrangement 25.100.000.040A ISSUE 1 10-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 93
INCLUDED IN KEY NO. 31, AAB8600 WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. 5" AND 10" LOW CAPACITY (200PPD) 5" AND 10" HIGH CAPACITY(750PPD) WALL-MOUNTED CONTROL UNIT - PARTS LIST Manual Arrangement 25.100.000.040B ISSUE 1 10-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 94
INCLUDED IN KEY NO. 31, AAB8600 WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. 5" AND 10" LOW CAPACITY (200PPD) 5" AND 10" HIGH CAPACITY(750PPD) WALL-MOUNTED CONTROL UNIT - PARTS LIST Manual Arrangement 25.100.000.040C ISSUE 0 10-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 95
V10K V-NOTCH CHLORINATOR NOTE: FOR PARTS LIST, SEE DWGS. 25.100.000.050C&D. 10" LOW CAPACITY (200PPD) AND 10" HIGH CAPACITY(750PPD) PANEL-MOUNTED CONTROL UNIT - PARTS Manual Arrangement 25.100.000.050A ISSUE 1 10-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 96
FOR CAPACITIES HIGHER THAN 500PPD, USE A 2" INJECTOR. SEE TYPICAL INSTALLATION DWGS. á IN SECTION 2. FOR PARTS LIST, SEE DWGS. 25.100.000.050C&D. 10" LOW CAPACITY (200PPD) AND 10" HIGH CAPACITY(750PPD) PANEL-MOUNTED CONTROL UNIT - PARTS Manual Arrangement 25.100.000.050B ISSUE 0 7-05 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 97
INCLUDED WITH KEY NO. 46, AAB8600 WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. 10" LOW CAPACITY (200PPD) AND 10" HIGH CAPACITY(750PPD) PANEL-MOUNTED CONTROL UNIT - PARTS LIST Manual Arrangement 25.100.000.050C ISSUE 1 10-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 98
INCLUDED WITH KEY NO. 46, AAB8600. WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. 10" LOW CAPACITY (200PPD) AND 10" HIGH CAPACITY(750PPD) PANEL-MOUNTED CONTROL UNIT - PARTS LIST Manual Arrangement 25.100.000.050D ISSUE 1 10-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 99
V10K V-NOTCH CHLORINATOR NOTE: FOR PARTS LIST, SEE DWGS. 25.100.000.060C&D. 5" AND 10" LOW CAPACITY (200PPD) 5" AND 10" HIGH CAPACITY(750PPD) PANEL-MOUNTED CONTROL UNIT- PARTS Automatic Arrangement 25.100.000.060A ISSUE 1 10-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 100
FOR CAPACITIES HIGHER THAN 500PPD, USE A 2" á INJECTOR. SEE TYPICAL INSTALLATION DWGS. IN 5" AND 10" HIGH CAPACITY(750PPD) SECTION 2. PANEL-MOUNTED CONTROL UNIT - PARTS FOR PARTS LIST, SEE DWGS. 25.100.000.050C&D. Automatic Arrangement 25.100.000.060B ISSUE 1 10-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 101
WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. 5" AND 10" LOW CAPACITY (200PPD) INCLUDED WITH KEY NO. 46, AAB8600. 5" AND 10" HIGH CAPACITY(750PPD) PANEL-MOUNTED CONTROL UNIT- PARTS LIST Automatic Arrangement 25.100.000.060C ISSUE 1 10-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 102
5" AND 10" LOW CAPACITY (200PPD) INCLUDED WITH KEY NO. 80, AAB8600. 5" AND 10" HIGH CAPACITY(750PPD) PANEL-MOUNTED CONTROL UNIT- PARTS LIST WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. Automatic Arrangement 25.100.000.060D ISSUE 1 10-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 103
V10K V-NOTCH CHLORINATOR NOTE: FOR PARTS LIST, SEE DWGS. 25.100.000.070B. SFC PANEL MOUNTING - PARTS 25.100.000.070A ISSUE 1 6-14 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 104
DINRAIL, 6-7/8” LG., SS AAD3947 V10K WIRING HARNESS PACKAGE SFC POSITIONER P50388 HOLE SEAL P36439 TERMINAL LUG AAD3977 PANEL WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. SFC PANEL MOUNTING - PARTS 25.100.000.070B ISSUE 0 10-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 105
V10K V-NOTCH CHLORINATOR NOTE: FOR PARTS LIST, SEE DWG. 25.100.001.210B. V10k CHLORINATOR - PARTS 5" Rotameter Components 25.100.001.210A ISSUE 0 7-05 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 106
5/8" DIA. GLASS FLOAT AIC5506 P48140 UXN25146 P52355 P35103 11/16" DIA. CERAMIC FLOAT AIC5506 P48140 WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. V10k CHLORINATOR - PARTS 5” Rotameter Components 25.100.001.210A ISSUE 1 10-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 107
V10K V-NOTCH CHLORINATOR NOTE: FOR PARTS LIST, SEE DWG. 25.100.001.220B. V10k CHLORINATOR - PARTS 10" Rotameter Components 25.100.001.220A ISSUE 0 7-05 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 108
5/8" DIA. GLASS FLOAT AIC5506 P48140 UXM20992 PXG48131 P35103 11/16" DIA. CERAMIC FLOAT AIC5506 P48140 WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. V10k CHLORINATOR - PARTS 10” Rotameter Components 25.100.001.220B ISSUE 1 10-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 109
PXG 39598 PXH 39598 PXJ 39598 PXK 39598 PXL 39598 PXM 39598 PXO 97057 WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. V10k V-NOTCH CHLORINATOR PLUGS - PARTS Automatic Arrangement 25.100.001.035 ISSUE 0 7-05 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 110
SEAT UNIT (HIGH CAPACITY 250 - 500 PPD) P37653 SPRING PXA33051 O-RING (009) VITON 7/32"ID x 11/32"OD WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. DIFFERENTIAL REGULATING VALVE - PARTS 25.152.001.011 ISSUE 1 4-05 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 111
V10K V-NOTCH CHLORINATOR U 26664 WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. PRESSURE RELIEF VALVE - PARTS 25.100.001.040 ISSUE 1 8-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 112
V10K V-NOTCH CHLORINATOR NOTE: FOR PARTS LIST, SEE DWG. 25.200.002.010B. AAA4310 3/4" STANDARD INJECTOR - PARTS 25.200.002.010A ISSUE 2 5-04 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 113
PXG 48961 PXG 48962 PXH 48961 PXH 48962 PXJ 48961 PXJ 48962 PXK 48961 PXS 48962 WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. AAA4310 3/4" STANDARD INJECTOR - PARTS LIST 25.200.002.010B ISSUE 4 4-05 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 114
V10K V-NOTCH CHLORINATOR NOTE: FOR PARTS LIST, SEE DWG. 25.200.002.020B. AAA4307 3/4" ANTI-SYPHON INJECTOR - PARTS 25.200.002.020A ISSUE 5 1-09 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 115
PXG 49042 PXG 48962 PXH 49042 PXH 48962 PXJ 49042 PXJ 48962 PXK 49042 PXS 48962 WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. AAA4307 3/4" ANTI-SYPHON INJECTOR - PARTS LIST 25.200.002.020B ISSUE 5 4-05 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 116
V10K V-NOTCH CHLORINATOR NOTE: FOR PARTS LIST, SEE DWG. 25.200.002.030B. AAA4316 1" STANDARD INJECTOR - PARTS 25.200.002.030A ISSUE 0 10-95 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 117
ANM3591 O-RING, VITON P48655 SPRING, POPPET P97049 GUIDE PLUG POP. P 1 00448 O-RING, VITON WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. AAA4316 1" STANDARD INJECTOR - PARTS LIST 25.200.002.030B ISSUE 1 8-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 118
V10K V-NOTCH CHLORINATOR NOTE: FOR PARTS LIST, SEE DWG. 25.200.002.040B. AAA4313 1" ANTI-SYPHON INJECTOR - PARTS 25.200.002.040A ISSUE 0 10-95 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 119
CLAMPING WASHER P97056 UNION PXG95967 SNAP RING P97064 SPRING P97051 CLAMPING NUT Pl 00448 O-RING, VITON WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. AAA4313 1" ANTI-SYPHON INJECTOR - PARTS LIST 25.200.002.040B ISSUE 2 8-08 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 120
WHEN REORDERING O-RINGS MARKED SPECIFY U21275 FOR PAIR. NOT SOLD SEPARATELY. WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. PLASTIC 1” FIXED THROAT INJECTOR AND TAILWAY DETAILS - PARTS 25.200.003.010A ISSUE 0 10-95 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 121
NON-STANDARD COMBINATION, MAY BE USED IF REQUIRED. IF NO SYMBOL IS INDICATED, COMBINATION CANNOT BE USED. WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. PLASTIC 1” FIXED THROAT INJECTOR AND TAILWAY DETAILS - PARTS LIST 25.200.003.010B ISSUE 0 10-95 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 122
LONG AND SHORTEN CHAIN AN EQUAL AMOUNT. WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. PLASTIC MAIN CONNECTION - PARTS For 3/4” Or 1” Solution Lines With 1” Corporation Cock 50.845.06.011 ISSUE 14 2-93 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 123
MAIN, APPROXIMATELY 1/2 TO 1/3 THE DIAMETER OF THE MAIN. CUT OFF THE TUBE IF TOO LONG. WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. MAIN CONNECTION - PARTS For 1” Solution Line and 1-1/2” Main Connections 50.845.06.012 ISSUE 5 10-88 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 124
APPROXIMATELY 1/2 TO 1/3 THE DIAMETER OF THE MAIN. CUT OFF THE TUBE IF TOO LONG. WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. MAIN CONNECTION - PARTS For 3/4” or 1” Solution Lines and 3/4” or 1” Main Connections 50.845.06.032 ISSUE 6 7-89 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 125
V10K V-NOTCH CHLORINATOR 21 22 NOTE: FOR PARTS LIST, SEE DWG. 25.052.001.051B. U25764 SMALL THROAT; U25765 LARGE THROAT 2" INJECTOR - PARTS With Manually Operated Plug Shut-Off 25.052.001.051A ISSUE 9 7-05 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 126
PART OF KEY NO. 42. NOTE: WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. U25764 SMALL THROAT; U25765 LARGE THROAT 2" INJECTOR - PARTS LIST With Manually Operated Plug Shut-Off 25.052.001.051B ISSUE 2 7-05 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 127
V10K V-NOTCH CHLORINATOR NOTE: FOR PARTS LIST, SEE DWG. 25.052.001.046B. U25762 SMALL THROAT; U25763 LARGE THROAT 2" INJECTOR - PARTS With Pressure-Operated Plug Shut-Off 25.052.001.046A ISSUE 5 4-05 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 128
INLET (BRONZE) P500 ADAPTER 1/8"NPT TO 1/4"HOSE (BRASS) WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. U25762 SMALL THROAT; U25763 LARGE THROAT 2" INJECTOR - PARTS LIST With Pressure-Operated Plug Shut-Off 25.052.001.046B ISSUE 8 7-05 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 129
V10K V-NOTCH CHLORINATOR WHEN ORDERING MATERIAL, ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. U19315 INJECTOR SHUT-OFF UNIT - PARTS 25.100.06.111 ISSUE 6 2-93 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 130
COMPLETE UNITS - NPT THREAD ONLY U 26316 FOR 1-1/2" HOSE, U 26320 FOR 2" HOSE. WHEN ORDERING MATERIAL ALWAYS SPECIFY MODEL AND SERIAL NUMBER OF APPARATUS. 2" MAIN CONNECTION - PARTS With Corporation Cock For 1-1/2" Or 2" Hose 50.845.002.022 ISSUE 4 9-03 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 132
1-inch Flexible Plastic Pipe RP68 4106 (Specify length) 3/4-inch Flexible Plastic Pipe RP68 4105 Halocarbon Grease U 27546 Ball Check for use with 2” Injector U 18966 OPTIONAL EQUIPMENT DESCRIPTION MODEL NO. Gas Flow Transmitter 55.114 Vacuum Switch 55.116 WT.025.100.001.UA.IM.0614 EVOQUA W3T109612...
Page 134
CHLORINE HANDLING MANUAL BOOK NO. WT.025.000.001.UA.IM.0614 W3T98244...
Page 135
Direct any questions concerning this equipment that are not answered in the instruction book to the Reseller from whom the equipment was purchased. If the equipment was purchased directly from Evoqua Water Tech- nologies, Colorado Springs, CO contact the office indicated below.
Page 136
CORDANCE WITH ALL GOVERNMENTAL REGULATIONS AND NATIONAL SAFETY CODES, AFTER GIVING FULL CONSIDERATION TO THE SPECIFIC NEEDS OF THE INDUSTRIAL FACILITY INVOLVED. EVOQUA WATER TECHNOLOGIES CANNOT ANTICIPATE THE SPECIFIC SAFETY PROCEDURES REQUIRED AT EVERY INDUSTRIAL FACILITY. ACCORDINGLY, EVO- QUA WATER TECHNOLOGIES DOES NOT GUARANTEE THAT SAFETY PROCEDURES...
Page 137
USE SAFETY EQUIPMENT TO PROTECT THE RESCUER This manual discusses the characteristics, storage and AND MOVE VICTIM TO FRESH AIR. IF BREATHING HAS handling of chlorine used with Evoqua Water Technologies STOPPED, START ARTIFICIAL RESPIRATION IMMEDI- equipment. Chlorine is used with Evoqua Water Technologies ATELY.
Among the important physical properties of chlorine are: Weight, Dry Gas 1 cf = 0.2006 lb at 32° F and 1 atm. Figure 1 – Chlorine Pressure vs Temperature WT.025.000.001.UA.IM.0614 EVOQUA W3T98244 PAGE 3...
Page 139
3.1.1 MANIFOLDING FOR GAS WITHDRAWAL Table 1 gives details on the supply containers most commonly used with Evoqua Water Technologies equipment. When higher gas withdrawal rates are required, cylinders or the gas valves (upper) of ton containers may be manifolded.
Page 140
(valve connection style #820, recognized by the Compressed Gas Association as the only acceptable means of connecting to container valves). The external threads on the container valve are used only for securing the protective cap. Figure 5 – Auxiliary Ton Container Valve WT.025.000.001.UA.IM.0614 EVOQUA W3T98244 PAGE 5...
Page 141
Avoid storage in subsurface areas because Figure 3. The fusible metal melts when the temperature chlorine is heavier than air and will not readily rise from WT.025.000.001.UA.IM.0614 EVOQUA W3T98244 PAGE 6...
Hand trucks should be well balanced and and the chlorine before it is used. equipped with chains or clamps to prevent the cylinders from falling off the truck. WT.025.000.001.UA.IM.0614 EVOQUA W3T98244 PAGE 7...
IN SUCH A MANNER (E.G., CHOCKS) TO PREVENT THEIR must be designed for and installed in such a manner to allow ROLLING OUT OF PLACE. for the significant increase in height as the car unloads. Since WT.025.000.001.UA.IM.0614 EVOQUA W3T98244 PAGE 8...
Do not run pres- becoming chilled, or liquid lines from becoming overheated. sure gas lines under windows from which cold air descends in winter months. WT.025.000.001.UA.IM.0614 EVOQUA W3T98244 PAGE 9...
The interior cross sectioned area of in Figure 13. a common vent or pressure relief line should be approxi- mately equal to the sum of the cross sectional areas of the individual vent lines. WT.025.000.001.UA.IM.0614 EVOQUA W3T98244 PAGE 10...
The piping should be tested in the prior to exposure to chlorine. smallest sections permitted by the existing valves to minimize WT.025.000.001.UA.IM.0614 EVOQUA W3T98244 PAGE 12...
The attending physician may wish to refer to a Material Safety Data Sheet on chlorine as well as to the Chlorine Institute’s In all cases, installations must comply with appropriate Chlorine Manual and/or Pamphlet 63, First Aid and Medical regulations. Management of Chlorine Exposures. WT.025.000.001.UA.IM.0614 EVOQUA W3T98244 PAGE 13...
CHEMTREC (toll free 800-4249300). In Canada, contact CANUTEC (call collect 613-996-6666). These names Emergency kits (meeting Chlorine Institute requirements) and numbers must also be posted prominently. are available that can seal off most leaking areas of chlorine WT.025.000.001.UA.IM.0614 EVOQUA W3T98244 PAGE 14...
The design of such a system is complex and should only be attempted by those thoroughly familiar with the process. WT.025.000.001.UA.IM.0614 EVOQUA W3T98244 PAGE 15...
Need help?
Do you have a question about the Wallace & Tiernan V10K and is the answer not in the manual?
Questions and answers