Download Print this page
Huawei NE20E-S8 Configuration
Hide thumbs Also See for NE20E-S8:

Advertisement

Quick Links

NE20E-S8 Configuration Help
1. New site or Expansion
This parameter is used for the NE20E-S to choose to purchase a new chassis or the
old chassis only expand LPU or upgrade software. If you want to purchase a new
NE20E-S , select "New site".If the software upgrade of the different version or the old
chassis only expand LPU, select "Expansion".
2. Please select the version
V800R008 supports the following: Hardware: Replacement of old hard pipe cards
with the 2-Port 10GBase LAN/WAN-SFP+ Physical Interface Card H and 8-Port
100/1000Base-X-SFP Physical Interface Card H Software: BRAS licenses, including
the NE20E-S Series PPPoE/IPoE Function License, NE20E-S Series Subscribers
Quantity(1k Subscribers) License, NE20E-S Series L2TP Function License. Please
confirm the corresponding iManager version is correct when you select the version:
V800R005:the corresponding iManager U2000 version is V100R009C00 or later;
V800R006:the corresponding iManager U2000 version is V200R014C50 or later;
V800R007: the corresponding iManager U2000 version is V200R015C50 or later;
eSight version is V300R003C10 or later; V800R008: the corresponding iManager
U2000 version is V200R016C50 or later; eSight version is V300R006C00 or later;
V800R009: the corresponding iManager U2000 version is V200R017C50 or later;
V800R010: the corresponding iManager U2000 version is V200R018C50 or later.
V800R011: the corresponding iManager U2000 version is V200R018C60 or later.
3. Please select the version that after upgrading
V800R008 supports the following: Hardware: Replacement of old hard pipe cards
with the 2-Port 10GBase LAN/WAN-SFP+ Physical Interface Card H and 8-Port
100/1000Base-X-SFP Physical Interface Card H Software: BRAS licenses, including
the NE20E-S Series PPPoE/IPoE Function License, NE20E-S Series Subscribers
Quantity(1k Subscribers) License, NE20E-S Series L2TP Function License. Please
confirm the corresponding iManager version is correct when you select the version:
V800R005:the corresponding iManager U2000 version is V100R009C00 or later;
V800R006:the corresponding iManager U2000 version is V200R014C50 or later;
V800R007: the corresponding iManager U2000 version is V200R015C50 or later;
eSight version is V300R003C10 or later; V800R008: the corresponding iManager
U2000 version is V200R016C50 or later; eSight version is V300R006C00 or later;
V800R009: the corresponding iManager U2000 version is V200R017C50 or later;
V800R010: the corresponding iManager U2000 version is V200R018C50 or later.
V800R011: the corresponding iManager U2000 version is V200R018C60 or later.

Advertisement

loading

Summary of Contents for Huawei NE20E-S8

  • Page 1 NE20E-S8 Configuration Help 1. New site or Expansion This parameter is used for the NE20E-S to choose to purchase a new chassis or the old chassis only expand LPU or upgrade software. If you want to purchase a new NE20E-S , select "New site".If the software upgrade of the different version or the old chassis only expand LPU, select "Expansion".
  • Page 2 5. Need Basic Software CD or not The basic software has been loaded on the equipment,and can be downloaded from http://support.huawei.com.The CD is not delivered by default. If the CD is required by customer,please choose 'YES'. 6. ===R01S300A Assembly=== o 6.1 Please select the capacitance of Rechargeable battery...
  • Page 3 NSP-B:provide NSP ability of 240G,don't support wide temperature range,support value-added service(IPSEC/NAT/VxLan/value-added service). NSP-C:provide NSP ability of 480G,don't support wide temperature range,support value-added service(IPSEC/NAT/VxLan/value-added). Network Service Processor (NSP-50) Network Service Processor (NSP-50-E, Apply for - 40~ 65degree scene) Network Service Processor (NSP-120-E) Network Service Processor (NSP-120) Network Service...
  • Page 4 Network Service Processor(NSP-B) o 7.3 Please select the quantity of NSP Double NSPs are suggested for 1+1(Turbo) backup or 1:1 backup. o 7.4 Need DC PDU or not 1.Including DC PDU and PGND cable, without power cable(the length of power cable is calculated automatically);2.The PDU of S2/S4/S8 could support 2 chassises.
  • Page 5 If configure with NSP-120/NSP-A/NSP-B, Sub-slots of No.3-No.6 can support this card. If configure with NSP-C, all slots can support this card. 3.Does not support outdoor application. 1-Port 40GBase- CFP Physical Interface Card(PIC) o 9.2 4-Port 10GBase LAN-SFP+ Physical Interface Card(PIC) Need be fixed with NSP-120/NSP-120-E, and NSP-50/NSP-50-E don't support this card.
  • Page 6 2. Mainly used in IP hard pipe scenario. o 9.7 2-Port 10GBase LAN/WAN-SFP+ Physical Interface Card H Specifications: 1)Support IP hard pipe 2)Support interface type:10GE 3)Specifications list: http://3ms.huawei.com/mm/docMaintain/mmMaintain.do?method=showMMDetail&f_i d=CIP180525031314083 Configuration precautions: 1)Need work with NSP-A/NSP- B/NSP-C. 2-Port 10GBase LAN/WAN-SFP+ Physical Interface Card H o 9.8 2-Port 10GBase LAN/WAN-SFP+ Physical Interface Card E(PIC-E)
  • Page 7 9.10 20-Port 100/1000Base-X-CSFP/10-Port 100/1000Base-X-SFP Physical Interface Card(PIC) Specifications: 1)Support interface type:GE/FE 2)Specifications list: http://3ms.huawei.com/mm/docMaintain/mmMaintain.do?method=showMMDetail&f_i d=CIP180525031314083 Configuration precautions: 1)Need configure with NSP- A/NSP-B/NSP-C, all slots can support this card. 2)20*GE CSFP card can be configured with both CSFP and SFP transceiver. Each CSFP transceiver can be work as 2 GE mode, while each SFP transceiver only work as 1 GE mode.
  • Page 8 1. Need work with NSP-A/NSP-B 2. Mainly used in IP hard pipe scenario. o 9.13 10-Port 100/1000Base-X-SFP Physical Interface Card E(PIC-E) 1.NSP-A/NSP-B/NSP-C support this card. If configure with NSP-A/NSP-B/NSP-C, all the sub-slot can support this card. 2.As this card with ETM chipset(enhanced Qos), it must insert in the slot which capacity bigger than 10G, or else the card would not registered.
  • Page 9 o 10.1 2-Port OC-3c/STM-1c (or 1-Port OC-12c/STM-4C) POS-SFP Physical Interface Card The model exchange between 155M and 622M control by command. The default mode is 155M. Need configure corresponding Optical Transceiver. 2-Port OC-3c/STM- 1c (or 1-Port OC-12c/STM-4C) POS-SFP Physical Interface Card o 10.2 1-Port Channelized STM-1c POS-SFP Physical Interface Card Need configure 155M SFP/eSFP Optical Transceiver.
  • Page 10 4-Port OC-3c/STM- 1c POS-SFP Physical Interface Card o 10.5 4 Channels GE/FE PoE Electrical Interface Board 1. The calbes should be done on site. 2. NSP-A/NSP-B support this card. If configure with NSP-A/NSP-B/NSP-C, all of the Sub-slots can support this card. o 10.6 32-Port E1 Physical Interface Card(PIC,120ohm) Need configure E1 Cable 32-Port E1 Physical...
  • Page 11 16-Port E1 Physical Interface Card(120ohm) o 10.9 16-Port E1 Physical Interface Card(PIC,75ohm) Need configure E1 Cable 16-Port E1 Physical Interface Card(75ohm) o 10.10 4-Channel FXS/FXO+2-Channel E&M+2-Channel RS232+2-Channel RS485 Board(MPA) 1. NSP-120/NSP-120-E/NSP-A/NSP-B support this card. 2. Can not support outdoor. 3. Two RS-485/RS-422 interfaces, based on the actual type of the peer device prepare cables on site.
  • Page 12 o 10.13 4 Channels C37.94 Optical Interface and 4 Channels CoDir64K Electric Interface Board(MP8A) 1. NSP-120/120-E/A/B support this card. 2. Can not support outdoor. 3. You need to configure the SFP optical modules for Optical Interface and 120 ohm E1 cables for Electric Interface 11.
  • Page 13 Does not support outdoor application 13. ===10G/GE Auto-adaptation XFP SFP+ Optical Transceiver=== o 13.1 XFP SFP+ Transceiver-SFP+-1310nm-10G/1G-Single-mode-LC- 10km Only below boards surpporting 10GE/GE auto-sensing optical transceiver: 03031DJP 4-Port 10GBase LAN/WAN-SFP+ Physical Interface Card 03031DJQ 1-Port 10GBase LAN/WAN-SFP+ + 8-Port 100/1000Base-X-SFP Physical Interface Card 03030WGQ 2-Port 10GBase LAN/WAN-SFP+ Physical Interface Card 14.
  • Page 14 Before enabling the DAA function, configure the PPPoE/IPoE license to support the basic BRAS functions. The DAA license is mandatory for the DAA functions. The DAA license is required to configure user license. o 15.7 Please input the quantity of the BRAS function access subscribers(K) Need work together with the PPPoE/IPoE function license.
  • Page 15 Need to configure this cable, while need to output "2M Primary Clock". 17.4 ===RS232/FXS/FXO/E&M port cable=== ▪ 17.4.1 Please input the quantity of RS232 MPA board supports RS232/RS485/RS422 interface, MPA board supports a maximum of two RS232 cable, two RS485/RS422. ▪...
  • Page 16 18.2 Please input the length of each device DC power cable (m) By default, Huawei provides blue cables (-48V) and black cables (GND), and cables of the other colors need to be remarked for purchase, and determine whether to purchase locally according to the actual situation.
  • Page 17 C13 PDU SF Power Socket PDU Cable C13- o 18.5 Select the type of C13 AC power cable Select the right type of AC power cable according to actual situation, if you can not confirm which one to choose, please refer to the power cable pictures and configuration instructions in the HELP document.
  • Page 18 C13Argentina C13Australia C13Brazil...
  • Page 19 C13Britain C13China Denmark C13-C13...
  • Page 20 C13Europe South Africa C13India...
  • Page 21 C13Italy C13Japan Korea C13-C13...
  • Page 22 C13North America C13Switzerland C13UKS(angled) o 18.6 Select the type of C13 PDU power cable 1.The recommended value is the power cable type allowed in the specific country. Do not change this value unless a specific power cable type is required. 2.If you don't know how to choose, please refer to the file , which is in Configuration help and the catalog is Appendix A Power Cable.