Siemens SIMATIC NET RUGGEDCOM RX1511 Installation Manual page 62

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX1511:
Table of Contents

Advertisement

IEC 61000-4-8
IEC 61000-4-11
IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
IEC 61000-4-29
IEC 60255-5
a
Siemens-specified severity levels.
EMC Immunity Type Tests for IEEE 1613
Note
The RUGGEDCOM RX1511 meets Class 2 requirements for an all-fiber
configuration and Class 1 requirements for copper ports. Class 1 allows for
temporary communication loss, while Class 2 requires error-free and interrupted
communications.
RUGGEDCOM RX1511
Installation Manual, 01/2021, C79000-G8976-1056-19
Test
Magnetic Field
Voltage Dips
and Interrupts
Damped Oscillatory
Mains Frequency
Voltage
Ripple on DC
Power Supply
Voltage Dips
and Interrupts
Dielectric Strength
HV Impulse
Description
HV Impulse
Dielectric Strength
Fast Transient
6.2 EMC and Environmental Type Tests
Description
Earth ground ports
Enclosure Ports
AC Power Ports
Signal ports
DC Power Ports
AC Power Ports
Signal ports
DC Power Ports
DC Power Ports
DC Power Ports
Signal ports
DC Power Ports
AC Power Ports
Signal ports
DC Power Ports
AC Power Ports
Signal ports
DC Power Ports
AC Power Ports
Signal ports
DC Power Ports
AC Power Ports
Signal ports
DC Power Ports
AC Power Ports
Certification
Test Levels
100 A/m, continuous
1000 A/m for 1 s
1000 A/m for 1 s
30% for 1 period
60% for 50 periods
2.5 kV common, 1 kV
differential mode @1 MHz
30 V Continuous
300 V for 1 s
10%
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
2 kV (Failsafe Relay output)
1.5 kV
2 kV
5 kV (Failsafe Relay output)
5 kV
Test Levels
5 kV (Failsafe Relay Output)
5 kV
2 kV
1.5 kV
2 kV
± 4 kV @ 2.5 kHz
± 4 kV
Severity
Levels
a
Note
5
 
3
4
3
 
 
53

Advertisement

Table of Contents
loading

Table of Contents