Curtis WB5N Series User Manual

Curtis WB5N Series User Manual

Hide thumbs Also See for WB5N Series:

Advertisement

USER GUIDE
WB5N Series
5 Gallon Water Boiler
READ AND SAVE THESE INSTRUCTIONS
NOTICE TO INSTALLER: Please leave this booklet with the machine.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WB5N Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Curtis WB5N Series

  • Page 1 USER GUIDE WB5N Series 5 Gallon Water Boiler READ AND SAVE THESE INSTRUCTIONS NOTICE TO INSTALLER: Please leave this booklet with the machine.
  • Page 2: Table Of Contents

    ............IP149 ........................ES97 ....................ES99 ..................ES145 ............................................................EC9 ..............................Contact Information Wilbur Curtis Co., Inc. 6913 Acco Street | Montebello, CA 90640 US Phone: 323-837-2300 | Toll Free: 800-421-6150 Email: csrassistance@wilburcurtis.com | Web: www.wilburcurtis.com . - 4:00 . PT Email: techsupport@wilburcurtis.com...
  • Page 3: Fs55

    KEY FEATURES/SPECIFICATIONS/SYSTEM REQUIREMENTS FS55 Key Features • G3 Digital Control Module – Provides precise control of temperature. • Agitation Pump – On-demand aeration improves tea extraction and food avor. • Easy-To-Operate – Simple graphics for all operating functions and ready lights. •...
  • Page 4: Is2

    INSTRUCTIONS could result in personal injury or void the warranty. • This appliance is designed for commercial use. Any service other than cleaning and preventive maintenance should be performed by an authorized Wilbur Curtis service technician. • serviceable parts inside.
  • Page 5 IMPORTANT SAFEGUARDS CE Requirements • This appliance must be installed in locations where it can be overseen by trained personnel. • • This appliance is not suitable for outdoor use. • • • This appliance must not be cleaned by water jet. •...
  • Page 6: Is15

    EU directive). Do not dispose of this appliance in domestic waste. Contact your local governing authorities for information on disposal requirements. • Any modi cations to equipment that are not approved by the Wilbur Curtis Company will render this declaration invalid. EC DIRECTIVES...
  • Page 7: Ii20

    INSTALLATION INSTRUCTIONS II20 WARNING: WARNING: properly grounded. NOTICE: SPECIFICATIONS section. IMPORTANT: Installation Instructions Installation Requirements • A secure surface capable of supporting the weight of the appliance. • For units without an attached cord set: Appropriately sized, UL listed, grounding type power cable to meet enough •...
  • Page 8: Ii27

    INSTALLATION INSTRUCTIONS II27 Installation NOTICE: Before proceeding, make sure that the counter is capable of supporting at least 81 lbs. (37 kg) to allow for the water boiler at full capacity. Leveling WARNING: Use the leveling legs to level the unit only.
  • Page 9 INSTALLATION INSTRUCTIONS II27 Connecting the Power Cord to A Junction Box (if applicable) If the power cord will be connected directly to the junction box, connect the power cable wires to the terminals in the junction box. See the ELECTRICAL SCHEMATIC for the power supply requirements.
  • Page 10 INSTALLATION INSTRUCTIONS II27 Powering up the Unit (cont.) All Units: 12 Make sure that the circuit breaker supplying power to the circuit is on. 13 Turn on the water supply valve. 14 Turn the toggle switch on the back of the unit to the ON Style varies 15 Check the water supply line for leaks.
  • Page 11: Oi40

    Press the AERATION (AIR) button to manually pump air through the water in the heating tank any Control Panel - WB5GT Series time you want. The aerator pump will run as long as you hold down the button. READY Control Panel - WB5N Series...
  • Page 12 TEMP ON/OFF AERATION Control Panel - WB5GT Series Control Panel - WB5N Series Programming Options Temperature (default is 204° F/96° C) Press the TEMP button for one second to check the control panel water temperature setting. To change the temperature setting, press the TEMP button for three seconds, then release, to enter temperature ) or the right ) to lower or raise the temperature.
  • Page 13 CLEANING INSTRUCTIONS CI16 WARNING: HOT SURFACES - To avoid injury, allow the unit to cool 30 minutes before cleaning. NOTICE - Do not use cleaning liquids, compounds or powders containing chlorine (bleach) or corrosives. USE OF THESE PRODUCTS WILL VOID THE WARRANTY.
  • Page 14 ROUGH-IN DRAWINGS RD61 WB5N Series 1.16 in [2.9 cm] 25.55 in [64.9 cm] 7.50 in [19.1 cm] 25.75in [65.4 cm] 13.63 in [34.6 cm] 3.51 in [8.9 cm] 19.99 in 0.85 in [50.8 cm] [2.2 cm] WB5N, ROUGH-IN DRAWING 122117NC...
  • Page 15 ROUGH-IN DRAWINGS RD61 WB5NL Series 1.16 in [2.9 cm] 25.55 in [64.9 cm] 7.50 in [19.1 cm] 25.75in [65.4 cm] 3.51 in 9.04 in [8.9 cm] [23.0 cm] 19.99 in 0.85 in [50.8 cm] [2.2 cm] WB5N, ROUGH-IN DRAWING 011518NC...
  • Page 16 ILLUSTRATED PARTS/RECOMMENDED PARTS IP102 WB5N[L] - Main Chassis - Exploded View Water tanks assemblies: Dual element, see section IP103 Single element, see section IP149 WB5N[B] Series WB5NL[B] Series WB5N, ILLUSTRATED PARTS/RECOMMENDED PARTS 071020E...
  • Page 17: Ip102

    WC-314 POWER BLOCK, 5 STATION WC-4426 SCREW, 8-32x3/8 PH HEAD TRUSS FAUCET ASSY, RED HANDLE 1-1/32-14 WC-1800HW UNS CURTIS WC-4544 SCREW, 8-32 x 1” PH TRUSS HD SCREW, 1/4-20 x 1/2 PHILLIPS PAN HEAD WC-4616 WC-4201 NUT, 8-32 HEX KEP ZINC...
  • Page 18: Ip103

    ILLUSTRATED PARTS/RECOMMENDED PARTS IP103 WC-62083, WC-62084 - Tank Assembly - Exploded View Water Level Probe Detail (Older Units) * Fitting location (hole in side of tank) varies based on part number: - WC-62083 = high location - WC-62084 = low location Parts List ITEM # PART #...
  • Page 19: Ip149

    ILLUSTRATED PARTS/RECOMMENDED PARTS IP149 WC-62083-31 - Tank Assembly Parts List ITEM # PART # DESCRIPTION ITEM # PART # DESCRIPTION WC-62083-31 TANK COMPLETE, (1) 2500W/220V WB5N31 THERMOSTAT, HI LIMIT HEATER CONTROL DPST WC-522 277V 40A WC-37008 LID ASSY, TANK (INCLUDES O-RING) WC-37365 KIT, FITTING TANK INLET WC-43067...
  • Page 20: Es97

    ELECTRICAL SCHEMATICS ES97 WB5GT63000/WB5N Series - Dual Voltage UCM Pin Assignments 16 Pin Connector UCM GROUND WATER LEVEL PROBE NOT USED NOT USED SOLID STATE RELAY - (+5Vdc) NOT USED ELECTRICAL RATING TABLE TANK TEMPERATURE SENSOR # of Tank Element...
  • Page 21: Es99

    ELECTRICAL SCHEMATICS ES99 WB5GT/WB5N - 220-240 Volt, Dual Element UCM Pin Assignments 16 Pin Connector UCM GROUND WATER LEVEL PROBE NOT USED NOT USED SOLID STATE RELAY - +5Vdc NOT USED TANK TEMPERATURE SENSOR TANK TEMPERATURE SENSOR NOT USED NOT USED INLET VALVE AIR PUMP 230V L1...
  • Page 22: Es145

    ELECTRICAL SCHEMATICS ES145 WB5N - 220-240 Volt, Single Element UCM Pin Assignments 16 Pin Connector UCM GROUND WATER LEVEL PROBE NOT USED NOT USED SOLID STATE RELAY - +5Vdc NOT USED TANK TEMPERATURE SENSOR TANK TEMPERATURE SENSOR NOT USED NOT USED INLET VALVE AIR PUMP 220-240V L1...
  • Page 23 TROUBLESHOOTING GUIDE TG32 WARNING: Electric Shock Hazard - Scald and Burn Hazard - IMPORTANT: always Valve Test Procedure Troubleshooting Guidelines If an error message appears on the display, consult the ERROR CODES • • • Use this troubleshooting guide along with the appropriate ELECTRICAL SCHEMATIC. •...
  • Page 24 TROUBLESHOOTING GUIDE TG32 Sensor Error Message (ERR1) Water Level Error Message (ERR2) ERROR CODES Water Tank Water Does Not Heat At All Tank Does Not Fill • If the water heats, but is not hot enough, see Water Not Hot Enough •...
  • Page 25 TROUBLESHOOTING GUIDE TG32 Water Too Hot (Boiling or Excessive Steaming) IMPORTANT: Aeration (Air) Does Not Work Water Tank Does Not Fill IMPORTANT: WB5, TROUBLESHOOTING GUIDE 010518NC...
  • Page 26: Ec9

    ERROR CODES System Fault Messages An error message will appear on the screen in the event of a malfunction under the following conditions: ERROR MESSAGE WARNING DESCRIPTION CAUSE ERR1 ERR2 WB5, ERROR CODES 010518NC...
  • Page 27 Return Merchandise Authorization (RMA): All returned equipment must be properly re-packaged in the original carton and received by Curtis within 45 days following the issuance of a RMA. NO UNITS OR PARTS WILL BE ACCEPTED WITHOUT A RETURN MERCHANDISE AUTHORIZATION (RMA).

This manual is also suitable for:

Wb5nWb5n63Wb5nlWb5nbWb5nlbWb5n30 ... Show all

Table of Contents