11.7 Disassembly and Replacement

[A] Process unit
(1)
Open the ADU cover and transfer unit.
(2)
Open the front cover and take off the toner
cartridge.
(3)
Disconnect 1 connector. Loosen 2 screws
and pull out the process unit.
Note:
When installing the process unit, make sure
that the connector (harness) is not caught
under the developer unit.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Process unit
Fig. 11-6
11 - 9