70
PERIODIC SERVICE
SERVICE AS REQUIRED
BReplacing Fuses
1. Raise the operator's seat.
2. Remove the blown fuse.
3. Place a new fuse of the same capacity in position.
(1) Fuse location
(2) Slow blow fuse
A When replacing the slow blow fuse, loosen the nuts
and remove the cover.
To avoid serious injury or death:
A Be sure to reinstall the removed cover after
replacing the slow blow fuse.
(1) Cover
(2) Nut
A If the new fuse happens to blow out within a short time,
contact your dealer for inspection and repair. Never
"jump" the fuse with wire or foil, or install a larger
capacity fuse than is recommended.
C Protected circuit
CAPACITY
FUSE NO.
(A)
20 A
15 A
15 A
(1)
15 A
10 A
(20 A)
Slow blow fuse
(2)
40 A
*Option: The fuse should be in only when the work light
is attached.
Protected circuit
Engine stop
Charge system
Main system
Aux. outlet
Control system
*(Work light)
Check circuit against
wrong battery connection
Need help?
Do you have a question about the ZD326-EU-2 and is the answer not in the manual?
Questions and answers