Ecode
Detail
Item
Code
E716
0000
Title
Erroneous communication with optional cassette or 2-way
unit
Description
After the presence of a cassette pedestal or a 2-way unit has
been detected, the communication fails to be normal for 5
sec.
Remedy
1.Check the cable.
2.Replace the DC Controller PCB (PCB4).
3.Replace the Cassette Pedestal Driver PCB.
4.Replace the 2-way unit driver PCB.
E716
0010
Title
Failure of the communication with the 2-way unit
Description
When the communication with the 2-way unit is faulty after
detecting the connection with the finisher.
Remedy
1.Install the 2-way unit.
2.Check the cable.
3.Replace the DC Controller PCB (PCB4).
4.Replace the 2-way unit driver PCB.
E719
0000
Title
Erroneous communication with New Card Reader (serial
communication)
Description
-
Remedy
-
E719
0002
Title
Erroneous communication with Coin Vendor (serial
communication)
Description
-
Remedy
-
E736
0000
Title
Erroneous communication between CCU and controller.
Description
-
Remedy
-
E744
0001
Title
Mismatched version between the language file and the
Bootable
Description
-
Remedy
-
E744
0002
Title
Oversized language file in HDD
Description
-
Remedy
-
E744
0003
Title
Mismatched version between the language file and the
Bootable
Description
-
Remedy
-
E744
0004
Title
Language file reading error
Description
-
Remedy
-
Description
Ecode
Detail
Item
Code
E804
0000
Title
Failure of the Power Supply Cooloing Fan (FAN6)
Description
When lock signal is detected for 5 sec while the Power
Supply Cooloing Fan (FAN6) is stopped.
* The same condition is detected after the error retry is
performed.
Remedy
1.Disconnect and then connect the connector (J205) on the
DC Controller PCB (PCB4).
2.Replace the Power Supply Cooloing Fan (FAN6).
3.Replace the DC Controller PCB (PCB4).
E804
0001
Title
Unstable rotation of the Power Supply Cooloing Fan (FAN6)
Description
When lock signal failed to be detected for 5 sec while the
Power Supply Cooloing Fan (FAN6) is driven.
* The same condition is detected after the error retry is
performed.
Remedy
1.Disconnect and then connect the connector (J205) on the
DC Controller PCB (PCB4).
2.Replace the Power Supply Cooloing Fan (FAN6).
3.Replace the DC Controller PCB (PCB4).
E805
0000
Title
Failure of the Exhaust Fan (Rear) (FAN3)
Description
When lock signal is detected for 5 sec while the Exhaust Fan
(Rear) (FAN3) is stopped.
* The same condition is detected after the error retry is
performed.
Remedy
1.Disconnect and then connect the connector (J206) on the
DC Controller PCB (PCB4).
2.Replace the Exhaust Fan (Rear) (FAN3).
3.Replace the DC Controller PCB (PCB4).
E805
0001
Title
Unstable rotation of the Exhaust Fan (Rear) (FAN3) or
Finisher Fan 1 (M8) or Finisher Fan 2 (M9)
Description
1.When lock signal failed to be detected for 5 sec while the
Exhaust Fan (Rear) (FAN3) is driven.
2.When lock signal failed to be detected for 5 sec while the
Finisher Fan 1 (M8) is driven.
3.When lock signal failed to be detected for 5 sec while the
Finisher Fan 2 (M9) is driven.
* The same condition is detected after the error retry is
performed.
Remedy
1.Disconnect and then connect the connector (J206) on the
DC Controller PCB (PCB4).
2.Replace the Exhaust Fan (Rear) (FAN3).
3.Replace the Finisher Fan 1 (M8).
4.Replace the Finisher Fan 2 (M9).
5.Replace the DC Controller PCB (PCB4).