Mitsubishi Electric MSZ-FH25VE - E1 Service Manual page 25

Indoor unit muz-fh-ve series; muz-fh-vehz series; mxz-d-va series
Hide thumbs Also See for MSZ-FH25VE - E1:
Table of Contents

Advertisement

10-3. INSTRUCTION OF TROUBLESHOOTING
Start
Indoor unit oper-
ates.
Outdoor unit
does not operate.
Outdoor unit
Outdoor unit
operates only
does not
in Test Run
operate even
operation.
in Test Run
operation.
Check room
Refer to "How
temperature
to check
thermistor.
inverter/com-
Refer to 10-7.
pressor".
"Test point
diagram and
voltage".
POWER lamp
Flash on and
off at 0.5-sec-
ond intervals
Cause:
Indoor/Outdoor
unit
• Miswiring or
trouble of
serial signal
Refer to
10-6. "How
to check mis-
wiring and
serial signal
error".
OBH623D
"Test Run operation" means the
operation within 30 minutes af-
ter EMERGENCY OPERATION
switch is pressed.
Indoor unit operates.
Outdoor unit does
not operate normally.
Indoor unit
Unit does not
operates, when
operate nor-
EMERGENCY
mal operation
OPERATION
in COOL or
switch is pressed.
HEAT mode.
Refer to
Refer to 10-6.
"Check of R.V.
"Check of remote
coil".
controller and
indoor electronic
control P.C. board".
POWER lamp
POWER lamp
2-time fl ash
3-time fl ash
Cause:
Cause:
Indoor unit
Indoor unit
• Trouble
• Trouble of
of room
indoor fan
temperature
motor
/ indoor coil
thermistor
Check room
Refer to
temperature
10-6.
thermistor
"Check of
and indoor
indoor fan
coil thermis-
motor".
tor. Refer to
10-7."Test
point diagram
and voltage".
Indoor unit does
POWER lamp on the
not receive the
indoor unit is fl ashing ON
signal from re-
and OFF.
mote controller.
Indoor unit does
not operate, when
EMERGENCY
OPERATION
switch is pressed.
1. Check indoor/out-
door connecting wire.
(Check if the power is
supplied to the indoor
unit.)
2. Refer to 10-6.
"Check
of indoor P.C. board
and indoor fan motor".
POWER lamp
POWER lamp
4-time fl ash
5-time fl ash
Cause:
Cause:
Indoor unit
Outdoor unit
• Trouble
• Outdoor
of indoor
power
unit control
system
system
abnormality
Replace the
Refer to
indoor elec-
"How to
tronic control
check
P.C. board.
inverter/com-
pressor".
25
If blinking of OPERATION INDI-
CATOR lamp cannot be checked,
it can be checked with failure
mode recall function.
AIR PURIFYING
lamp
2-time fl ash
cause:
indoor unit
• Trouble of AIR
PURIFYING
power control
Refer to 10-6. "Check of
AIR PURIFYING power".
Refer to outdoor unit service manual.
POWER lamp
POWER lamp
6-time fl ash
7-time fl ash
Cause:
Cause:
Outdoor unit
Outdoor unit
• Trouble of
• Trouble of
outdoor con-
thermistor in
trol system
outdoor unit
Refer to
Replace the
"Check of
inverter P.C.
outdoor ther-
board or
mistors".
the outdoor
electronic
control P.C.
board.
POWER lamp
14-time fl ash
or more
Cause:
Outdoor unit
• Other ab-
normality
Check "Flow
chart of the
detailed
outdoor unit
failure mode
recall func-
tion."