Sharp KB-3411JS Supplemental Service Manual page 21

Free standing range with microwave drawer
Hide thumbs Also See for KB-3411JS:
Table of Contents

Advertisement

Pin No.
Signal
I/O
48-52
P04-P00
OUT
53
P57
OUT
54
P56
IN
55
TXD1
IN
56
RXD1
IN
57
P53
IN
58
P52
OUT
59
P51
IN
60
INT0
IN
61
AVSS
IN
62
VREF
IN
63
AN7
IN
64
AN6
IN
the signals holds "H" level during microwave cook-
ing and "L" level while not cooking. In other cook-
ing modes (90%, 80%, 70%, 60%, 50%, 40%,
30%, 20%, 10%, 0%) the signal turns to "H" level
and "L" level in repetition according to the power
level.
Used for initial balancing of the bridge circuit (absolute humidity sensor).
Common relays driving signal. (Square Waveform : 60Hz)
To turn on and off the shut-off relays (RY1 and
RY3). The square waveform voltage is delivered
to the relays (RY1 and RY3) driving circuit.
Signal coming from key unit.
Signal coming from key unit.
Signal coming from key unit.
To input signal which communicates the oven door open/close information to LSI.
Door open "H" level signal (+5V). Door close "L" level signal (GND).
Signal to sound buzzer.
A: Key touch sound.
B: Completion sound.
C: When the oven stops so that the food can be
checked in Automatic cooking mode.
Input signal which communicates the drawer door open/ close information to LSI.
Door opened; "H" level signal(+5V).
Door closed; "L" level signal(0V).
Signal to synchronize LSI with commercial power source frequency.
This is the basic timing for all real time processing of LSI.
A/D converter power source voltage.
The power source voltage to drive the A/D converter in the LSI.
Reference voltage input terminal.
A reference voltage applied to the A/D converter in the LSI. Connected to +5V.
AH sensor input.
This input is an analog input terminal from the AH sensor circuit, and connected to the A/
D converter built into the LSI.
Used for initial balancing of the bridge circuit (absolute humidity sensor). This input is an
analog input terminal from the AH sensor circuit, and connected to the A/D converter built
into the LSI.
19
Description
VARI MODE
100% power
90% power
80% power
70% power
60% power
50% power
40% power
30% power
20% power
10% power
0% power
A
B
1.0 sec
C
KB-3411JS
KB-3411JK
KB-3411JW
Microwave cooking mode
Other cooking mode
ON TIME OFF TIME ON TIME OFF TIME
32 sec.
0 sec.
60sec.
0ec.
30 sec.
2 sec.
54sec.
6sec.
26 sec.
6 sec.
48sec.
12sec.
24 sec.
8 sec.
42sec.
18sec.
22 sec.
10 sec.
36sec.
24sec.
18 sec.
14 sec.
30sec.
30sec.
16 sec.
16 sec.
24sec.
36sec.
12 sec.
20 sec.
18sec.
42sec.
8 sec.
24 sec.
12sec.
48sec.
6 sec.
26 sec.
4sec.
56sec.
0 sec.
32 sec.
0sec.
60sec.
16.7 msec.
H: +5V
L: GND
During cooking
H : +5V
L : GND
16.7 msec.
0.1 sec
2.0 sec
1.0 sec
H: +5V
L: GND

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kb-3411jkKb-3411jw