Contents Precautions ············································································································· 1 Features of This Unit ································································································ 2 Names and Functions ······························································································ 4 Connections ·········································································································· 12 Operations ············································································································· 16 How to use Remote Control ·················································································· 18 Block Diagram ······································································································· 20 Specifications ········································································································ 21 Before Asking for Repair Services ·········································································· 22...
Precautions INTEGRATED AMPLIFIER L-590AXII Installation place Cautions in connecting speakers This unit shall be installed in a well-ventilated and effectively When making speaker system connections, exercise extra heat-released place because this unit is an A-class amplifier care not to short-circuit between ! and @ of the speaker and generates considerable heat.
Features of This Unit New LECUA1000 — LUXMAN Electric Parallel speaker relays Controlled Ultimate Attenuator 1000 This unit is equipped with large speaker relays in 2 parallel structure with a low resistance value to reduce the imped- New LECUA1000, which is the integration of an amplifier cir- ance of the speaker output lines.
Page 5
INTEGRATED AMPLIFIER L-590AXII Phono amplifier Cast-iron insulator This unit is equipped with a phono amplifier that is compat- This unit is equipped with gradation cast-iron insulators that ible with the MM/MC cartridge to achieve analog record re- cuts out unnecessary external vibration and strongly supports production in a high-grade level without adding a dedicated the weight of this unit.
Names and Functions Front panel 1. Operation switch (OPERATION) 3. Input selector (INPUT SELECTOR) Toggles the power on and off. Selects an input device from the devices such as a CD play- When wiring or connection is performed, be sure to turn off er, an SACD player and a tuner connected to each input this switch.
Page 7
INTEGRATED AMPLIFIER L-590AXII 5. Display window 9. Separate switch (SEPARATE) Displays the operation status of this unit. Separates the pre-amplifier and main-amplifier. This display is composed of 7 indicators and 2 power me- off (separate indicator off): ters. Uses this unit as an integrated amplifier.
Page 8
Names and Functions Front panel 10. Line straight switch (LINE STRAIGHT) 11. Balance control (BALANCE) Enhances the purity of the sound quality by bypassing the Adjusts the balance of sound volume between right and left balance control circuit, tone control circuit, or the like. channels.
Page 9
INTEGRATED AMPLIFIER L-590AXII 13. Tone control for bass 16. Cartridge selection switch TONE CONTROL (BASS) (CARTRIDGE) Controls the frequency characteristics in the low-frequency Changes the gain level of the equalizer amplifier (amplifier range. circuit required to play an analog record).
Page 10
Names and Functions Display window 1. Monitor indicator (MONITOR) 3. Subsonic indicator (SUBSONIC) Lights up when the monitor switch is on. Lights up when the subsonic switch is on. 2. Power meters 4. Monaural indicator (MONO) The left meter reads the output of the L channel, and the Lights up when the monaural switch is on.
Page 11
INTEGRATED AMPLIFIER L-590AXII 5. Standby indicator (STAND BY) 8. Line straight indicator (LINE STRAIGHT) Lights up when the AC plug is plugged into a wall socket Lights up when the line straight switch is on. and the operation switch is set to off.
Page 12
Names and Functions Rear panel 1. Signal ground 3. LINE-1, LINE-2, LINE-3, and LINE-4 (ground terminal) (SIGNAL GROUND) input terminals (unbalanced) (LINE-1, LINE-2, LINE-3, and LINE-4) Is a ground terminal for devices to be connected to this unit. This terminal is used to reduce noise when other devices Are used for high-level signal inputs from a CD player, an are connected.
Page 13
INTEGRATED AMPLIFIER L-590AXII 5. Pre-out terminal (PRE OUT) 8. Phase inverters (PHASE) This terminal is used to obtain the output of the preamplifier. Change the phase when the balance input terminal is used. A bi-amp connection can be performed with a combination...
Connections CD/SACD PLAYER CD/SACD PLAYER RECORDER – – – – ANALOG PLAYER SPEAKER SYSTEM ( A ) SPEAKER SYSTEM ( B )
Page 15
INTEGRATED AMPLIFIER L-590AXII Before Connecting How to connect CD player, SACD player, tuner, or other devices Before connecting other devices, connect the jack side of the accessory power cable to the AC inlet of this unit. Connect between the output terminals of a CD player, an...
Page 16
Connections CD/SACD PLAYER CD/SACD PLAYER RECORDER – – – – ANALOG PLAYER SPEAKER SYSTEM ( A ) SPEAKER SYSTEM ( B )
Page 17
INTEGRATED AMPLIFIER L-590AXII How to connect record player When you need not toggle an input source to be record- Connect between the output terminals of an analog record ed (especially when a recorder connected to the recorder player and the PHONO terminals of this unit with 2 (R and output terminals is recording), do not operate this switch.
Operations Before operation How to operate the tone control 1. Ensure that the connections are correctly performed. This unit has the tone control function for the low-frequency (Normal playback cannot be performed with wrong con- and high-frequency ranges. nections of R, L, !, or @.) The low-frequency range type works in the 300 Hz or lower.
Page 19
INTEGRATED AMPLIFIER L-590AXII Procedure of timer-controlled recording Memory 1. Turn on the operation switch to activate this unit. This unit stores the following items when the power is off: 2. Select a source to be recorded under timer control with the input selector.
How to use Remote Control Remote control (RA-17A) 1. Operation switch (OPERATION) 4. Separate switch (SEPARATE) Toggles the power on and off. Separates the pre-amplifier and main-amplifier. When wiring or connection is performed, be sure to turn off off (separate indicator off): this switch.
Page 21
INTEGRATED AMPLIFIER L-590AXII 7. Subsonic switch (SUBSONIC) 11. Volume (VOLUME, i, o) Cuts ultra-low frequencies out of audible range to prevent This button is used to adjust the sound volume. The sound ultra-low range noise from adversely affecting audible range.
Specifications INTEGRATED AMPLIFIER L-590AXII Continuous power output 30 W + 30 W (8 Ω) 60 W + 60 W (4 Ω) Total harmonic distortion 0.005 % (8 Ω, 1 kHz both channels simultaneous drive, line straight on) 0.02 % (8 Ω, 20 Hz to 20 kHz both channels simultaneous drive, line straight on)
Before Asking for Repair Services While the unit is used, an unusual phenomenon may be confused as a malfunction for a certain reason. Prior to asking our official sole distributor of your country for repair services, please check the table below and read the operating instructions for the subsidiary devic- es.