SENSe Commands
[:SENSe]:ACQuisition:SAMPles(?)
Syntax
Arguments
Measurement Views
Examples
Related Commands
[:SENSe]:ACQuisition:SEConds(?)
Syntax
Arguments
Measurement Views
Examples
Related Commands
2- 484
Sets or queries the acquisition samples (number of samples acquired over the
acquisition time) when [:SENSe]:ACQuisition:MODE is set to SAMPles.
[:SENSe]:ACQuisition:SAMPles <value>
[:SENSe]:ACQuisition:SAMPles?
<value>::=<NR1> specifies the acquisition samples.
Range: 2 to 1 G samples.
All
:SENSe:ACQuisition:SAMPles 1114
sets the acquisition samples to 1114.
[:SENSe]:ACQuisition:MODE
Sets or queries the acquisition length (time over which the acquisition occurs)
when [:SENSe]:ACQuisition:MODE is set to LENGth.
[:SENSe]:ACQuisition:SEConds <value>
[:SENSe]:ACQuisition:SEConds?
<value>::=<NRf> specifies the acquisition length.
All
:SENSe:ACQuisition:SAMPles 12.5ms
sets the acquisition length to 12.5 ms.