Advertisement

Quick Links

GETTING STARTED GUIDE
PXIe-5830
5 GHz to 12 GHz, 1 GHz Bandwidth, Vector Signal Transceiver
Note
Before you begin, install and configure your chassis and controller.
This document explains how to install, configure, and test the PXIe-5830. The PXIe-5830 is
an RF vector signal transceiver (VST). You can program the PXIe-5830 instrument using
RFmx or NI-RFSA and NI-RFSG driver software.
The PXIe-5830 instrument configuration comprises the following modules:
PXIe-5820 Vector Signal Transceiver
PXIe-3621 Vector Signal Up/Down Converter
There is no single instrument labeled "PXIe-5830."
Contents
Verifying the System Requirements..........................................................................................2
Unpacking the Kit..................................................................................................................... 2
Verifying the Kit Contents................................................................................................ 3
Preparing the Environment....................................................................................................... 4
Choosing and Installing the Software....................................................................................... 5
Software Options...............................................................................................................5
Installing the Software...................................................................................................... 5
Installing the PXIe-5830........................................................................................................... 6
Interconnecting the PXIe-5830 Modules.......................................................................... 8
Direct Connections to the PXIe-5830..................................................................................... 10
Configuring the PXIe-5830 in MAX...................................................................................... 10
Self-Calibration....................................................................................................................... 11
Performing a Self-Calibration Using NI-RFSA.............................................................. 11
Locating the Software and Examples......................................................................................13
Software Locations......................................................................................................... 13
Programming Examples Locations................................................................................. 15
Making a First Measurement.................................................................................................. 16
Troubleshooting...................................................................................................................... 17
What Should I Do if the PXIe-3621 Does Not Appear in MAX?.................................. 17
Why Is the ACCESS LED Off When the Chassis Is On?...............................................17
What Should I Do if the PXIe-5830 Fails the Self-Test?................................................18
What Should I Do if the Instrument Does Not Initialize?...............................................18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PXIe-5830 and is the answer not in the manual?

Questions and answers

Summary of Contents for NI PXIe-5830

  • Page 1: Table Of Contents

    Note Before you begin, install and configure your chassis and controller. This document explains how to install, configure, and test the PXIe-5830. The PXIe-5830 is an RF vector signal transceiver (VST). You can program the PXIe-5830 instrument using RFmx or NI-RFSA and NI-RFSG driver software.
  • Page 2: Verifying The System Requirements

    Worldwide Support and Services.................... 26 Verifying the System Requirements To use the PXIe-5830, your system must meet certain requirements. For more information about minimum system requirements, recommended system, and supported application development environments (ADEs), refer to the readme, which is installed or available at ni.com/manuals.
  • Page 3: Verifying The Kit Contents

    A PXI Express embedded controller or MXI controller system that meets the system requirements specified in this guide and chassis documentation. Optional Items • A 0.9 N · m (8 lb · in.) calibrated torque wrench, 5/16 in. (NI part number 751120-01). PXIe-5830 Getting Started Guide | © National Instruments | 3...
  • Page 4: Preparing The Environment

    Preparing the Environment Ensure that the environment you are using the PXIe-5830 in meets the following specifications. Operating ambient temperature 0 °C to 45 °C Operating relative humidity 10% to 90%, noncondensing (IEC 60068-2-56) Maximum altitude 2,000 m (800 mbar) (at 25 °C ambient...
  • Page 5: Choosing And Installing The Software

    Related Information Refer to the RFmx SpecAn Help, the RFmx Demod Help, the NI RF Vector Signal Analyzers Help, or the NI RF Signal Generators Help for more information about using the RFmx, NI- RFSA, and NI-RFSG instrument driver FPGA extensions.
  • Page 6: Installing The Pxie-5830

    Install the driver software using NI Package Manager or by inserting your driver software media into your computer. If you do not already have NI Package Manager installed, visit ni.com/r/NIPMDownload to download NI Package Manager. Refer to the NI Package Manager Manual...
  • Page 7 5. PXI Express Peripheral Slot 3. PXI Express Hybrid Peripheral Slot The modules that comprise the PXIe-5830 can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots. Touch any metal part of the chassis to discharge static electricity.
  • Page 8: Interconnecting The Pxie-5830 Modules

    Incorrect torque at SMA connections can damage device connectors and degrade signal fidelity. Connecting the PXIe-5820 and PXIe-3621 Complete the following steps for the baseband signal connections and Reference Clock connection, as shown in the following figure. 8 | ni.com | PXIe-5830 Getting Started Guide...
  • Page 9 I/Q OUT I- I/Q IN I- I/Q OUT Q+ I/Q IN Q+ I/Q OUT Q- I/Q IN Q- I/Q IN I+ I/Q OUT I+ I/Q IN I- I/Q OUT I- PXIe-5830 Getting Started Guide | © National Instruments | 9...
  • Page 10: Direct Connections To The Pxie-5830

    This completes the Reference Clock connection. Direct Connections to the PXIe-5830 The PXIe-5830 is a precision RF instrument that is sensitive to ESD and transients. Ensure you are making proper direct connections to the PXIe-5830 to avoid damaging the hardware.
  • Page 11: Self-Calibration

    Self-test the hardware by selecting the item in the configuration tree and clicking Self- Test in the MAX toolbar. Repeat this step for all modules in your PXIe-5830 system. The MAX self-test performs a basic verification of hardware resources.
  • Page 12 Select the device identifier assigned to the PXIe-3621 in MAX in the [Resource Name] drop-down menu. Set Clock Source to OnboardClock. Set Self Calibration Step Operations to Perform All Self Calibration Steps. Run the VI. 12 | ni.com | PXIe-5830 Getting Started Guide...
  • Page 13: Locating The Software And Examples

    Windows 10 (32-bit)/8.1 (32-bit)/7 (32-bit)- Program Files\National Instruments • Windows 10 (64-bit)/8.1 (64-bit)/7 (64-bit)- Program Files (x86)\National Instruments Microsoft .NET For the location of .NET class libraries, refer to the installed RFmx readme. PXIe-5830 Getting Started Guide | © National Instruments | 13...
  • Page 14 Table 3. Location of PXIe-5830 Software Options (Continued) Software Location Option NI-RFSA LabVIEW Available on the LabVIEW Functions palette at Measurement I/O»NI-RFSA. LabWindows/CVI Available in the \Drivers\niRFSA <IVIROOTDIR32> directory, where is one of the <IVIROOTDIR32> following locations: • Windows 10 (32-bit)/8.1 (32-bit)/7 (32-bit)- Program Files\IVI Foundation\IVI •...
  • Page 15: Programming Examples Locations

    Solution Explorer in Visual Studio. Programming Examples Locations Using the NI Example Finder If you are using RFmx, NI-RFSA, or NI-RFSG with LabVIEW or LabWindows/CVI, use the NI Example Finder to locate programming examples. Launch LabVIEW or LabWindows/CVI.
  • Page 16: Making A First Measurement

    You can verify proper installation and configuration of your instrument by making a measurement using the NI-RFSG and RFmx Soft Front Panels (SFPs). Connect the PXIe-5830 IF IN/OUT 0 and IF IN/OUT 1 ports as appropriate for your application. Select Start»All Programs»National Instruments»NI-RFSG»NI-RFSG Soft Front Panel to launch the NI-RFSG SFP.
  • Page 17: Troubleshooting

    Related Information Interconnecting the PXIe-5830 Modules on page 8 Troubleshooting If an issue persists after you complete a troubleshooting procedure, contact NI technical support or visit ni.com/support. What Should I Do if the PXIe-3621 Does Not Appear in MAX? In the MAX configuration tree, expand Devices and Interfaces.
  • Page 18: What Should I Do If The Pxie-5830 Fails The Self-Test

    What Should I Do if the Instrument Does Not Initialize? Failure to initialize may indicate a problem with module interconnections or with MAX. If the niRFSA Initialize VI or niRFSG Initialize VI returns an error and the PXIe-5830 fails to initialize, complete the following steps: Reconnect the PXIe-5830 front panel cables securely.
  • Page 19: Hardware Connectors And Indicators

    Input connector that allows for the use of an external 10 MHz MMPX (f) Reference Clock. REF OUT Output connector that can export a 10 MHz Reference Clock. MMPX (f) PXIe-5830 Getting Started Guide | © National Instruments | 19...
  • Page 20 MMPX (f) I/Q IN Input connector for I+ signals. MMPX (f) Input connector for I- signals. MMPX (f) Input connector for Q+ signals. MMPX (f) Input connector for Q- signals. MMPX (f) 20 | ni.com | PXIe-5830 Getting Started Guide...
  • Page 21 The indicators are listed in increasing order of priority. For example, if you are generating a waveform using NI-RFSG and waiting on an acquisition Reference Trigger in NI-RFSA, the LED is dim amber. PXIe-5830 Getting Started Guide | © National Instruments | 21...
  • Page 22 MGT REF– / DIO 1 DIO 3 MGT Rx+ 2 MGT Tx+ 2 MGT Rx– 2 MGT Tx– 2 MGT Rx+ 3 MGT Tx+ 3 MGT Rx– 3 MGT Tx– 3 5.0 V Reserved 22 | ni.com | PXIe-5830 Getting Started Guide...
  • Page 23: Pxie-3621 Front Panel And Leds

    I/Q IN Input connector for I+ signals. MMPX (f) Input connector for I- signals. MMPX (f) Input connector for Q+ signals. MMPX (f) Input connector for Q- signals. MMPX (f) PXIe-5830 Getting Started Guide | © National Instruments | 23...
  • Page 24 OUT Output connector for the Reference Clock. MMPX (f) RESERVED Reserved connectors are not enabled for use on the — PXIe-5830 and should remain capped with 50 Ω terminators to ensure specified instrument performance. 24 | ni.com | PXIe-5830 Getting Started Guide...
  • Page 25 • GREEN—The module is ready to be programmed by software. ACTIVE • OFF—The module is idle. • RED—The module detected an error state. PXIe-5830 Getting Started Guide | © National Instruments | 25...
  • Page 26: Where To Go Next

    *This item is also installed with the driver software. † The VST device information is also located in the NI RF Vector Signal Analyzer Help or the NI RF Signal Generators Help. The NI RF Vector Signal Transceivers Help, available at ni.com/manuals, is an HTML version of a traditional user manual that includes detailed information about RF fundamentals, device features, and programming for vector signal transceivers.
  • Page 27 NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For support outside the United States, visit the Worldwide Offices section of ni.com/niglobal...
  • Page 28 . You can find patents.txt ni.com/patents information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at for the NI global trade compliance policy and how ni.com/legal/export-compliance...

This manual is also suitable for:

Pxie-3621Pxie-5820

Table of Contents