Contents 1. Sygnal Connect Operation ........................4 2. Connect LCD Touchpad Functions ...................... 5 2.1 Touchpad Layout ........................... 5 2.2 Turning all zones ON or OFF * ....................... 6 2.3 Selecting the Conditioning Mode * ....................6 2.4 Selecting the Zone Mode * ......................6 2.5 Viewing a zones status * .......................
1. Sygnal Connect Operation Your Sygnal Connect control system coordinates the operation of the Sygnal indoor and outdoor units and zone dampers to provide the finest indoor climate control solution currently available. The system features variable refrigeration and airflow (VRAF) and multi-zone variable air volume (VAV) capacity modulation to ensure the appropriate amount of heating or cooling capacity is distributed to each area.
* in the heading. If access to a function has been limited the LCD touchpad will respond with a beep only. (For more information refer to Sygnal Connect Installation Manual). Access to the following functions is available by default from any LCD touchpad.
2.2 Turning all zones ON or OFF * ZONE 1. Press until the global screen is displayed. 2. Press to turn all zones on or off as required. General system information scrolls across the bottom line of the LCD when the system is on. E.g.
2.6 Turning a zone ON or OFF ZONE 1. Press to select a zone. 2. Press to turn the zone on or off as required. 2.7 Setting a zone temperature / Position (setpoint) Zone damper behaviour is determined by whether a zone sensor is connected to the zone sensor output at the zone control modules.
6. Press and hold to scroll quickly through the available characters. MODE 7. Press to move to the next character. Press to return to the previous character to correct mistake. 8. Repeat for all eight character spaces. 9. Pressing to accept the final character will save the zone name and the controller will return to the standard display.
8. Use to alter the start time to the correct value (in 10 minute intervals). Program stop: ALL zones 9. Press to proceed to the stop time. The top line will scroll: Stop: AL 05:30 pm 10. Use to alter the stop time then press to complete setting the global timer program and return to normal operation.
3. Room Controller operation Room controllers provide On/Off control for individual zones. When no temperature target is required for a zone a room controller is not required. Zone On/Off Button Heating indicator LED On/Off Indicator LED Cooling Indicator LED Copyright. Sygnal 2018...
4. Manufacturers Recommendations The following information is a guide to efficient use of your new Sygnal system. Following these tips will contribute to the long life of the unit and could save you money. 4.1 Essential Operating Guidelines The Filters must be in place to run the unit. Never operate the unit without the filters. 4.2 Tips for saving energy ...
6. Troubleshooting Problem Possible Solution Air Conditioner has restarted but does not operate The normal operating behaviour to protect the for 4 minutes compressor. Wait until the air conditioner begins operating. The unit has entered defrost mode to melt the frost which has accumulated on the outdoor unit.
6.1 Digital Inverter System Diagnostics / Fault detection. Sygnal systems are able to detect a number of problems and display a fault message to aid in troubleshooting. If any fault messages are displayed contact your installer/service person. Fault D1 – 3 Phase error Digital Outdoor Line1 = Fault D1: Line 2 scrolls one of the following:...
6.2 Dual Inverter System Diagnostics / Fault detection. Sygnal systems are able to detect a number of problems and display a fault message to aid in troubleshooting. If any fault messages are displayed contact your installer/service person. Fault I1 – Indoor and Outdoor unit not compatible Line1 = Fault I1: Line 2 scrolls one of the following:...
7. Warranty terms and conditions All goods which are the company’s own are guaranteed against faulty workmanship, materials or design for a period of 12 months from the date of despatch, after which all liability on the part of the Company ceases, save: a) Goods which are branded Sygnal, registered with Sygnal prior to the expiration of the standard 12 month warranty period, form part of the air conditioning unit and are used in a human comfort application.
8. Warranty key points in large print. Sygnal HVAC systems used in human comfort applications are covered by a parts and labour on-site warranty as explained in detail later in this document. Sygnal is committed to making sure that our clients get years of trouble free operation from what we believe to be the world’s best residential concealed ducted air conditioning system.
Need help?
Do you have a question about the Connect and is the answer not in the manual?
Questions and answers