Wiring
● Using line synchronization setting and 8-core cable
<Using PNP output>
Emitter
6.8kΩ
6.8kΩ
0.1μF
6.8kΩ
0.1μF
Internal circuit
Receiver
6.8kΩ
0.1μF
6.8kΩ
Internal circuit
*S1
Switch S1
● Test / Reset input
Manual reset ...Vs to Vs − 2.5V (sink current 5mA or less): Emission halt (Note), Open: Emission
Auto reset ...Vs to Vs − 2.5V (sink current 5mA or less): Emission (Note), Open: Emission halt
● Interlock setting input, External device monitor input
Vs to Vs − 2.5V (sink current 5mA or less): Valid (Note), Open: Invalid
Note: Vs is the supply voltage.
<Reference>
K1, K2: External device (forcible guide relay or magnetic conductor)
48
(Brown) +V
470Ω
(Pale purple) Interlock setting input
470Ω
(Pink) Test / Reset input
6.8kΩ
(Red) Auxiliary output
(Pale blue) Output polarity setting /
Lockout release input
(Blue) 0V
(Orange) Synchronization +
(Orange / Black) Synchronization -
Users' circuit
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Brown) +V
470Ω
(Pale purple) External device monitor input
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Pale blue) Output polarity setting /
Lockout release input
(Blue) 0V
Users' circuit
*S1
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
*S1
+
24V DC
+20
%
-30
Load
K1 K2
K1
K2