Download Print this page
Panasonic SF-C14EX-01 Instruction Manual
Panasonic SF-C14EX-01 Instruction Manual

Panasonic SF-C14EX-01 Instruction Manual

Application expansion unit exclusive for light curtain

Advertisement

Quick Links

Application Expansion Unit Exclusive for Light Curtain
SF-C14EX-01
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the
correct and optimum use of this product. Kindly keep this manual in a
convenient place for quick reference.
English and Japanese are original instructions.
WARNING
When using this product as a safety equipment for a press machine
in Japan, always use this product, SF4B-□-01<V2> and cable with
protective tube SFPB-CB□-EX in combination. Other combinations
are not acceptable as a safety equipment for a press machine.
1
SAFETY PRECAUTIONS
● This product has been developed / produced for industrial use only.
● Use this product as per its specifications. Do not modify this product since
its functions and capabilities may not be maintained and it may malfunction.
● Use of this product under the following conditions or environment is not presupposed.
Please consult us if there is no other choice but to use this product in such an environment.
1) Operating this product under conditions or environments not described in this manual.
2) Using this product in the following fields: nuclear power control, railroad, aircraft,
automobiles, combustion facilities, medical systems, aerospace development, etc.
● When this product is to be used for enforcing protection of a person from
any danger occurring around an operating machine, the user should satisfy
the regulations established by national or regional security committees (Oc-
cupational Safety and Health Administration: OSHA, the European Stan-
dardization Committee, etc.). Contact the relative organization(s) for details.
● In case of installing this product to a particular machine, follow the
safety regulations in regard to appropriate usage, mounting (instal-
lation), operation and maintenance. The users including the installa-
tion operator are responsible for the introduction of this product.
● Use this product by installing suitable protection equipment as a
countermeasure for failure, damage, or malfunction of this product.
● Before using this product, check whether the product performs proper-
ly with the functions and capabilities as per the design specifications.
● In case of disposal, dispose this product as an industrial waste.
2
CAUTIONS
WARNING
● Machine designer, installer, employer and operator
• The machine designer, installer, employer and operator are solely
responsible to ensure that all applicable legal requirements relat-
ing to the installation and the use in any application are satisfied.
• Whether this product functions as intended and systems including this
product comply with safety regulations depends on the appropriateness
of the application, installation and operation. The machine designer,
installer, employer and operator are solely responsible for these items.
● Engineer
• The engineer would be a person who is appropriately educated,
has widespread knowledge and experience, and can solve vari-
ous problems which may arise during work, such as a machine
designer, or a person in charge of installation or operation, etc.
● Operator
• The operator should read this instruction manual thoroughly, under-
stand its contents, and perform operations following the procedures
described in this manual for the correct operation of this product.
• In case this product does not perform properly, the operator should report this to
the person in charge and stop machine operation immediately. The machine must
not be operated until correct performance of this product has been confirmed.
● Environment
• Do not use a mobile phone or a radio phone near this product.
• Do not install this product in the following environments.
1) Areas with high humidity where condensation is likely to occur
2) Areas exposed to corrosive or explosive gases
3) Areas exposed to vibration or shock of levels higher than that specified
4) Areas exposed to contact with water
5) Areas exposed to too much steam or dust
● Machine in which this product is installed
• Do not install this product with a machine whose operation cannot be stopped im-
mediately in the middle of an operation cycle by an emergency stop equipment.
• This product starts the performance after 2 sec. from the power
ON. Have the control system started to function with this timing.
● Wiring
• Be sure to carry out the wiring in the power supply OFF condition.
• All electrical wiring should conform to the regional electrical regulations and laws.
The wiring should be done by engineer(s) having special electrical knowledge.
• Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
INSTRUCTION MANUAL
WARNING
● Maintenance
• The periodical inspection of this product must be performed by
an engineer having the special knowledge.
● Others
• Never modify this product.
● When connecting this product to a product other than the connect-
able input device, the system does not conform to the control cat-
egory 4 based on ISO 13849-1 (EN ISO 13849-1).
● Connect this product to the same power supply which the light cur-
tain uses.
● Take care that wrong wiring will damage the product.
● Verify that the supply voltage variation is within the rating. Take care
that if a voltage exceeding the rated range is applied, or if an AC
power supply is directly connected, the product may get burnt or
damaged.
● The DC power supply unit must satisfy the conditions given below:
1) Power supply unit authorized in the region where this product is
to be used.
2) Power supply unit SELV (safety extra low voltage) / PELV (pro-
tected extra low voltage) conforming to EMC Directive and Low-
voltage Directive (In case CE Marking conformity is required.)
3) Power supply unit conforming to the Low-voltage Directive and
with an output of 100VA or less.
4) The frame ground (F.G.) terminal must be connected to ground
when using a commercially available switching regulator.
5) Power supply unit with an output holding time of 20ms or more.
6) In case a surge is generated, take countermeasures such as
connecting a surge absorber to the origin of the surge.
7) Power supply unit corresponding to CLASS 2 (only for requiring
UL
Mark conformation).
C
US
● This product is not dust-proof / splash proof. Be sure to put this
product into a control box having IP54 construction.
● Avoid dust, dirt, and steam.
● Take care that the product does not come in contact with water, oil,
grease, or organic solvents such as thinner, etc.
● The seal as shown in the drawing on the right
is stuck to the engagement point of unit. If
the seal is peeled off or broken, this product
will not be certified as a "Safety equipment"
and will not be covered by our guarantee.
● Note that this product is applicable only in the control circuit grounded in
accordance with IEC 60204-1 and JIS B 9960-1, or in the control circuit in
which the insulation monitor unit (ground fault detection unit) is arranged.
● This product is suitable for indoor use only.
OUTLINE
3
● This is the application expansion unit which can control three differ-
ent safety outputs in combination with the light curtain.
It exhibits the following features:
1) Either PNP or NPN output can be selected with the slide switch.
2) It can be connected to the light curtain using the exclusive 8-core
connection cable with connectors.
3) A detachable spring gauge terminal is employed.
4) The three auxiliary outputs (muting output, override output and blown
lamp output) and the auxiliary output of the light curtain are incorporated.
5) The interference prevention wiring among the light curtains is pos-
sible. Maximumly three sets in series / parallel mixed connection can
be configured with the interference prevention system. The number of
total beam channels in series / parallel mixed connection is 192 max.
● This device complies with the following standards / regulations.
<EU Directives>
EU Machinery Directive 2006/42/EC
EMC Directive 2004/108/EC (Valid until April 19, 2016)
EMC Directive 2014/30/EU (Valid from April 20, 2016)
RoHS Directive 2011/65/EU
<European Standards>
EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1: 2008 (Category 4, PLe)
<International Standards>
IEC 61496-1 (Type 4), ISO 13849-1: 2006 (Category 4, PLe)
<Japanese Industrial Standards (JIS)>
JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4)
<Standards in US / Canada)>
ANSI/UL 61496-1 (Type 4), ANSI/UL 508, UL 1998 (Class 2)
CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8
<Regulations in US>
OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has
certified with the type examination certificate.
With regard to the standards in US / Canada, a NRTL, UL (Under-
writers Laboratories Inc.) has certified for
<Reference>
The conformity to JIS, OSHA and ANSI for this device has been evaluated by ourselves.
● The light curtains that can be used in combination with this product are as follows.
SF4B<V2> series and SF4B-□-01<V2>
UL
Listing Mark.
C
US

Advertisement

loading

Summary of Contents for Panasonic SF-C14EX-01

  • Page 1 ● Others • Never modify this product. Thank you very much for purchasing Panasonic products. ● When connecting this product to a product other than the connect- Please read this Instruction Manual carefully and thoroughly for the able input device, the system does not conform to the control cat- correct and optimum use of this product.
  • Page 2 CAUTIONS FUNCTIONAL DESCRIPTION INSTALLATION POSITION / DIRECTION / METHOD ● Use the 35mm width DIN rail to install the unit. 1. Emitter side connector ● The installation position / direction is not basically limited. 2. Receiver side connector ● Please fix this product with the DIN rail stopper MS-DIN-E (optional) 11.
  • Page 3: Timing Chart

    TIMING CHART <Wiring for PNP output (Manual reset)> Emitter side Receiver side Output polarity selection switch <Normal operation> connector connector The diagram shows operation with safety outputs 1 / 2 in manual-reset 24V DC mode. (*2) Emergency stop switch Light F.G.
  • Page 4 <Blown lamp output> ● Reset operation The diagram shows operation with safety outputs 1 / 2 in auto-reset WARNING mode. Light Design the system such that the reset switch can be operated from received Light curtain outside the dangerous area, and also where the operators can see Light the entire dangerous area.
  • Page 5 Labor, Basic Publication No. 446-2, issued on July 9, 1993) for details. ● Compatible press machines 2. Connection between a unit of light curtain and SF-C14EX-01 • When using this product as a safety equipment for a press machine <When connecting to emitter of the light curtain>...
  • Page 6 Designation received Application expansion unit exclusive for light curtain Light received status Light Model No. SF-C14EX-01 blocked 14ms or less SF4B<V2> series and SF4B-□-01<V2> Connectable input device EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4,PLe) Safety input of this device...
  • Page 7: 14 Troubleshooting

    EU Representative’s Name: (orange) light up. rectly. state. • Check if the emergency stop Panasonic Marketing Europe GmbH Panasonic Testing Center All of the safety switch has been “pressed.” EU Representative’s Address: outputs 1, 2 and 3 are OFF.