Habitat HTE-01 Programming Manual
Hide thumbs Also See for HTE-01:

Advertisement

Smarter Control Solutions.
Programming Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HTE-01 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Habitat HTE-01

  • Page 1 Smarter Control Solutions. Programming Guide...
  • Page 2: About This Manual

    About This Manual This manual uses special attention icons to alert the user of (1) Important safety concerns, (2) Instructions on proper operation of control functions and (3) Installation/set up information. Safety: Indicates a condition which may cause severe personal injury, death or major property damage.
  • Page 3: Table Of Contents

    Web Site: www.habitattechnologies.com customerservice@habitat.support Manual Table of Contents About This Manual HTE-01 Thermostat - Home Screen Display HTE-01 Thermostat - Controls HTM-01 Base Module - LED Status Indication HTE-01 Thermostat - Parameter Setup - Identify HTM-01 Base Module(s) - Pairing Additional HTM-01 Base Module(s) 9-10 - Daylight Savings Time, Date &...
  • Page 4 Home Screen Display...
  • Page 5 Pairing status indicator: Connected Time display Not connected WIFI status indicator (only shown Override status indicator: when WIFI module is in use.) Override – Temporary Override Connected Perm. Override – Permanent Override Not Connected Thermostat Battery power indicator Schedule running indicator: status, only shown when on battery power.
  • Page 6: Hte-01 Thermostat Controls

    HTE-01 Thermostat Controls Front View Bottom Side View...
  • Page 7 LCD Display – See preceding pages for detailed descriptions of the display icons. – Increase or Decrease the target temperature set point. Changing the target set point: • Press the button while in Auto, Heat or Cool Modes. • If a schedule is programmed, “Override” is displayed below the time indicating that the current target setpoint will be maintained until the: - Next schedule period...
  • Page 8: Htm-01 Base Module Led Status Indication

    HTM-01 Base Module LED Status Indication The following table shows the base module state corresponding to the LED Status Indication. LED Status Indication State Description Flashing Base module is seeking to pair with Pairing Green the thermostat. Green Base module is paired with the thermostat. Paired Base module is not paired with a thermostat.
  • Page 9 Parameters Setup To access Parameters, hold down the Mode and Fan buttons until a beep sounds (3 seconds), then release. Use the Fan button to scroll forward and the Mode button to scroll backward through the available parameters. Parameter Description Action Identify existing base module(s) Base Module...
  • Page 10: Identify Htm-01 Base Module(S)

    Identify HTM-01 Base Module(s): To access Parameters, Press If any module has been hold down the Mode and identify base modules. paired but has lost its Fan buttons until a beep “All” flashes indicating link to the Thermostat, sounds (3 seconds), then all modules.
  • Page 11 The LED on the module corresponding to the ID selected will begin Press Fan to select The module ID stops flashing red for 10 the module desired. flashing, and 10-minute minutes. If “All” is countdown timer begins. selected, the LEDs on all connected modules will flash red.
  • Page 12: Pairing Additional Htm-01 Base Module(S)

    Pairing Additional HTM-01 Base Module(s): To access Parameters, hold The display will Use the button down the Mode and Fan show the number to begin a 10-minute buttons until a beep sounds of base modules countdown to pair (3 seconds), then release. currently paired.
  • Page 13 The pairing sequence will time out after 10 minutes. To exit the parameters menu, hold down the Mode and Fan buttons until a beep sounds (3 seconds). The Habitat HTE-01 Thermostat will support a maximum of eight HTM-01 Base Modules...
  • Page 14: Daylight Savings Time, Date & Time Settings

    Daylight Savings Time, Date & Time Settings Daylight Savings Time: Use : Use : Use button to toggle buttons to set buttons to set DST Mode . Press the month. Press Fan the date. Press Fan to Fan to continue. to continue.
  • Page 15: Emergency Heat Setting

    Emergency Heat Setting: buttons to enable (y) or disable (n) Emergency Heat. When enabled, if the room temperature falls below the Emergency Heat Setpoint (Administrative Parameter), emergency backup heat will be activated. Press Fan to advance to the next parameter.
  • Page 16: Setback Setting

    Setback Setting: Use the buttons to choose enable ( ), disable ) or use a setback motion sensor ( Use the Use the buttons buttons to change to change the the cooling setback heating setback temperature. Press Fan temperature. to advance to the next Press Fan to parameter.
  • Page 17: External Temperature Sensor

    External Temperature Sensor: Use the buttons to to choose between external sensor disabled (n) and external sensor enabled (y).
  • Page 18: Schedule Setup

    Schedule Setup: Hold down the The display will Press Mode to scroll When prompted back to the Schedule Mode and Fan show the number Parameter and use buttons until a beep of base modules button sounds (3 seconds), currently paired. buttons to toggle to toggle schedule then release.
  • Page 19 • Period Setup buttons to Use the buttons set the minutes for the first period. to set the hour that the first period Press Fan to continue. begins. Press Fan to continue. buttons Set time and to set the target set point buttons to set the target temperature set for Cooling.
  • Page 20 To disable a period, press After the 6th period is Once all periods and day button until programmed, the HTE-01 groups have been is displayed. Thermostat will move to programmed, a prompt Up to 6 periods per day the next day or group,...
  • Page 21: Hte-01 Thermostat Administrative Parameters

    HTE-01 Thermostat Administrative Parameters To access Administrative Parameters, hold down the Mode and Fan buttons until the second beep sounds (10 seconds) is displayed. Use the buttons to change . Use the Fan button to scroll forward and the Mode button to scroll back.
  • Page 22: Off Delay

    Parameter Display Description Use the buttons to toggle between “n” (default) and “y”, then press Fan to select. Selecting “y” enables the AUTO mode Enable Auto selection using the Mode button. Changeover Note: Disabling Auto Changeover by pressing “n” will change schedule mode to the current HEAT or COOL mode.
  • Page 23 Parameter Display Description Use the buttons to set Compressor Off Delay Time. Range 3 to 5 minutes Compressor Off Delay Time Default 5 minutes Increment 1 minute Use the buttons to change the minimum differential between the heat and cool setpoints. Press Fan to accept. If this value is changed, the current set point, schedule set point, min/max setpoint or freeze Heat/Cool...
  • Page 24 Parameter Display Description Use the buttons to set the temperature offset between the room sensor reading and display/set point temperature. This is to eliminate a discrepancy between the sensor reading Temperature and actual temperature if it exists. Press Offset Fan to accept and go to the next parameter.
  • Page 25 Parameter Display Description Use the buttons to set the maximum temperature set point for heating. Press Fan to accept and go to the next parameter. Maximum The minimum heating set point is fixed at 41°F (5°C). Point - Heating Range 45°F to 89°F (7°C to 31.5°C) Increment 1°F (0.5°C)
  • Page 26 1 to 5 minutes Period Default 1 minute Increment 1 minute Use the buttons to toggle between “n” to “y”, then press Fan. Factory Reset “3” will be displayed briefly before the HTE-01 begins the re-boot process, starting with displaying all segments.