In the absence of local requirements, follow ANSI/NFPA 70, National Electric Code. • The HTE-01 Thermostat may be used with a 24 VAC power source or battery power only. DO NOT APPLY supply voltage above 30 VAC. • DO NOT expose the HTE-01 Thermostat to voltage fluctuations of more than ±2.4 VAC (±10% of nominal power rating).
About This Manual This manual uses special attention icons to alert the reader of important safety concerns, information important to reliable operation of the controls or helpful installation/setup information. Safety: Indicates a condition which may cause severe personal injury, death, or major property damage. Important Information: Indicates information which requires special attention for correct operation of the control.
Safety Instructions About This Manual What’s in the Box Device Overview System Dip Switch Configuration HTM-01 Base Module Installation LED Status Indication HTE-01 Thermostat Installation Power Installation Boot Screen Display Device Pairing 11-12 Home Screen/Controls 13-16 Appendix A - Wiring Diagrams...
What’s In The Box BEFORE BEGINNING installation, confirm that all parts are present in the package: (2) Mounting Screws (2) AA Alkaline Batteries HTE-01 Thermostat (2) Wall Anchors with Mounting Plate HTM-01 Base Module HTM-01 Base Module HTM-01 Base Module...
11-12 for the device pairing procedure. A single Model HTE-01 thermostat can control up to eight air conditioning units equipped with Model HTM-01 base modules. The range between the thermostat and the base modules can be up to approximately 50 feet...
HTM-01 Base Module Installation • Mount the Base Module: Using the double-sided adhesive backing on the Base Module mount it to a convenient location on the appliance. Status LED PAIR Button RJ-45 HTZ-01 Connector Double-sided Water Leak Sensor Adhesive Cable Connection Wiring Harness Connection Avoid mounting the HTM-01 Base Module in locations near line...
Page 10
For best results, the HTM-01 base module is to be mounted in a convenient location on the HVAC unit where there is no sheet metal between the base module and the thermostat. The HTM-01 can be mounted on the inside of an enclosure behind louvers or grill (Figure 1).
Page 11
For HVAC units with an open bottom, place as close to the bottom as possible while avoiding places where furnishings or cleaning equipment can cause damage (Figure 3). Figure 3 – Units with open bottoms – Inside Cabinet...
LED Status Indication The following table shows the base module state corresponding to the LED Status Indication. LED Status Indication State Description Flashing Base module is seeking to pair with Pairing Green the thermostat. Green Base module is paired with the thermostat. Paired Base module is not paired with a thermostat.
HTE-01 Thermostat Installation Mount the Thermostat: Remove Mounting Plate and mount it approximately 4-5 feet above the floor. Select an area with average temperature and good air circulation. BE SURE that the symbol is correctly oriented. DO NOT MOUNT the thermostat near any heat source, behind doors or curtains, in corners, in direct sunlight, in areas of high humidity or where water is present.
Power Installation If using 24 VAC supply wiring, be sure that the wire goes through the opening in the Mounting Plate before mounting. FOR 24 VAC INSTALLATIONS, insert the low voltage supply wires into the terminations provided and tighten the screws. DO NOT OVERTIGHTEN Hardwired Installation the terminal screws.
Boot Screen Display When the HTE-01 Next, the firmware Then the display Thermostat is first version is displayed briefly shows the powered, all segments for 2 seconds. system type which are briefly displayed. is dependent on the dip switch settings.
Device Pairing The HTE-01 Thermostat and the HTM-01 Base Module that were shipped together were paired at the factory for convenience. To add additional base modules, use the following procedure. Hold down the Fan, Mode, and buttons for more than 3...
Page 17
HTE-01 thermostat begins the pairing process with a 10 minute countdown timer. As the HTE-01 Thermostat pairs with each HTM-01 Base Module the number of paired modules is displayed. A maximum of 8 base modules can be paired with each thermostat.
Page 19
Celsius or Fahrenheit units Mode status Emergency heat indication Additional system type text Fan speed indication 1 - Schedule must be activated for the time & schedule status to be displayed. See the Habitat programming guide for information on setting up a schedule.
Page 20
HTE-01 Thermostat Controls Front View Bottom Side View...
Page 21
LCD Display – See preceding pages for detailed descriptions of the display icons. – Increase or Decrease the target temperature set point. Changing the target set point: • Press the button while in Auto, Heat or Cool Modes. • If a schedule is programmed, “Override” is displayed below the time indicating that the current target setpoint will be maintained until the: - Next schedule period...
Appendix A - Wiring Diagrams Most PTAC, WSHP, and HWSHP systems support two-speed fan operation. In a single speed fan system, wires for Gh, Gm, and Gl should be connected to the fan relay output of the appliance. Always refer to the equipment manufacturer’s specifications for remote thermostat operation.
Page 23
Most PTAC, WSHP, and HWSHP systems support two-speed fan operation. In a single speed fan system, wires for Gh, Gm, and Gl should be connected to the fan relay output of the appliance. Always refer to the equipment manufacturer’s specifications for remote thermostat operation.
Page 24
Most PTAC, WSHP, and HWSHP systems support two-speed fan operation. In a single speed fan system, wires for Gh, Gm, and Gl should be connected to the fan relay output of the appliance. Always refer to the equipment manufacturer’s specifications for remote thermostat operation.
Page 25
Most PTAC, WSHP, and HWSHP systems support two-speed fan operation. In a single speed fan system, wires for Gh, Gm, and Gl should be connected to the fan relay output of the appliance. Always refer to the equipment manufacturer’s specifications for remote thermostat operation.
Page 26
Most PTAC, WSHP, and HWSHP systems support two-speed fan operation. In a single speed fan system, wires for Gh, Gm, and Gl should be connected to the fan relay output of the appliance. Always refer to the equipment manufacturer’s specifications for remote thermostat operation.
For warranty issues, please contact the HVAC professional that installed this product. y You can register your products in two ways: Email: y Please go to: warrantyregistration@habitat.support Mail: y Please complete the Warranty Registration Form and mail it in to the address shown.
Page 28
Name _____________________________________________________________________ Address ___________________________________________________________________ ___________________________________________________________________ City ______________________________________________________________________ EMAIL: ____________________________________________________________________ Thermostat Model ___________________ Serial Number ____________________ Module Model _____________________ Serial Number ______________________ Installed Date _____________________________________ Mail to: Habitat Technologies Warranty Registration Dept. 330 East 38th Street, Suite 530 New York, NY 10016-0444...
Appendix C - Specifications Model HTE-01 Thermostat Temperature Units °C or °F Operating Temperature 32°F - 99°F / 0°C - 40°C Indoor Temperature 32°F - 113°F / 0°C - 45°C Measurement Range Hardwired: 18 to 30 VAC, NEC Class II,...
Appendix D - Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 31
FCC AND INDUSTRY CANADA RF Radiation Exposure statement: This equipment complies with FCC and Industry Canada RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the antenna and all persons. Cet appareil est conforme aux limites d’exposition au rayonnement FR du FCC et d’Industrie Canada pour un environnement non contrôlé.
Smarter Control Solutions. Designed and Engineered in New York. U.S. Registered Trademark. Patents pending www.habitattechnologies.com HC-IM-HTE-01-HTM-01-2020.05 v2...
Need help?
Do you have a question about the HTE-01 and is the answer not in the manual?
Questions and answers