RRU3260
Installation Guide
Prerequisites
Before the installation, single-mode optical modules can be distinguished from multi-mode
optical modules in either of the following ways:
l
l
The optical modules to be installed must match CPRI rates.
Context
l
l
Procedure
Step 1 Lower the pullers of two optical modules, insert one optical module into the CPRI0 port on the
RRU and the other optical module into the CPRI port on the BBU, and raise the pullers, as shown
in
Figure
Figure 9-22 Installing an optical module
The performance of an optical module that is exposed to the air for more than 20 minutes may
be abnormal. Therefore, you must insert an fiber optic cable into an unpacked optical module
within 20 minutes.
Step 2 Connect the end labeled 1A and 1B of the fiber optic cable to the optical module on the RRU
side, as shown in
Issue ()
SM and MM labels on an optical module: SM indicates a single-mode optical module, and
MM indicates a multi-mode optical module.
Color of the puller on an optical module: Blue indicates a single-mode optical module, and
black or gray indicates a multi-mode optical module.
CAUTION
A CPRI fiber optic cable transmits CPRI signals between a BBU and an RRU.
For details about CPRI fiber optic cable connections, see section "CPRI Cable Connections"
in the BBU3900 Hardware Description or DBS3900 Hardware Description.
9-22.
CAUTION
Figure
9-23.