Method For Checking And Cleaning Radiator Fins, Oil Cooler Fins, Aftercooler Fins, Fuel Cooler Fins, And Air Conditioner Condenser Fins - Komatsu PC700LC-11 Operation & Maintenance Manual

Hydraulic excavator
Table of Contents

Advertisement

MAINTENANCE PROCEDURE
3.
Insert a ruler into the grease through the inspection and
adjustment hole (A). Check that the height of grease (a) is
at least 10 mm . If it is insufficient, add it.
Measure with the ruler by inserting it into the position (A)
shown in the right figure.
4.
Check that the grease is not milky white. If the grease is
milky white, it needs to be replaced. Ask your Komatsu
distributor to replace it.
Total amount of grease: 31 ℓ (28 kg )
5.
Install the cover (2) with bolt (1).
METHOD FOR CHECKING AND CLEANING RADIATOR FINS, OIL COOLER FINS,
AFTERCOOLER FINS, FUEL COOLER FINS, AND AIR CONDITIONER CONDENS-
ER FINS
If the compressed air, high-pressure water, or steam hits your body directly or dirt is scattered by use of
it, there is a danger of personal injury. Wear the protective equipment such as the protective eyeglasses
and dust mask.
NOTICE
When using the compressed air, blow it from some distance to avoid damaging the fins. Damage on the
fins can cause water leakage and overheating. Especially when blowing the compressed air against the
fuel cooler and aftercooler by 45° angle, keep the nozzle at least 300 mm away from them. In a dusty job
site, check the fins every day, regardless of the maintenance interval.
1.
Open the rear duct (1) on the right side of the machine.
Remove the upper cover (2).
2.
Clean the net (3) which is installed to the duct.
4-50
k
k
WARNING
MAINTENANCE

Advertisement

Table of Contents
loading

Table of Contents