Disturbance Recording and Fault Locating Device DRL6600U
Product version: V8.30
Description
Surge immunity test
• Communication
• Other ports
Power frequency (50 Hz) magnetic
field
• 3s
• Continuously
Power frequency immunity test
• Common mode
• Differential mode
Voltage sag and short interruption
• Sag
• Interruption
Electromagnetic launch test
• Transmission, radio frequency,
launch(main terminal)
0.15...0.50MHz
0.5...30MHz
• Radiation, radio frequency, launch
30...230MHz
230...1000MHz
ABB
Type test value
1kV line to ground
2kV line to ground, 1kV line to
line
1000A/m
100A/m
RMS 300V
RMS 150V
40%/200ms
70%/500ms
0-100ms: No restart
0...∞s: Behave normally at
power off
< 79dB(µV) quasi peak
< 66dB(µV) mean value
< 73dB(µV) quasi peak
< 60dB(µV) mean value
< 50dB(µV/m) quasi peak,
locate from 3m away
< 57dB(µV/m) mean value,
locate from 3m away
4CAE000359
Issued: May 2017
Reference standard
IEC 61000-4-5
IEC 60255-22-5, 3 level
IEC 61000-4-8, level 4
IEC 60255-22-7, level A
IEC 60255-11
IEC 61000-4-17
EN55011, level A
IEC 60255-25
Revision: -