  • Page 1 COD: 30Z12/24.B.2021 Installation, use and maintenance manual ZEN 30 12/24 V dc...
  • Page 2: Table Of Contents

    ..........................23 4.5 E LECTRIC CONNECTIONS ..........................26 4.5.1 R EMOTE CONTROL PANEL INSTALLATION ....................26 4.5.2 E (ZEN 30 12/24V DC) ..............27 LECTRIC CONNECTIONS WIRES 5. FUNCTIONING AND USE ..........................29 5.1 C OMMAND DESCRIPTION ..........................29 5.1.1 A LARMS DESCRIPTION ..........................
  • Page 3 7. TROUBLESHOOTING ............................42 7.1 T ROUBLESHOOTING CHART ..........................42 8. SUGGESTED SPARE PARTS ......................... 43 8.1 S HORT TERM CRUISING ........................... 43 8.2 L ONG TERM CRUISING ............................. 43 Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 4: Layout Of Manual

    This symbol indicates accident prevention regulations for the operator and / or for any exposed persons. CAUTION: This symbol indicates that there is the possibility of damaging the system and / or its components. NOTE: This symbol indicates useful information. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 5: General Warnings And Information To The Recipient

    All rights of reproduction of this manual are reserved to SCHENKER ITALIA. This manual cannot be transferred to third parties without the written authorization of SCHENKER ITALIA.
  • Page 6: Warranty

    36-month warranty, as long as the watermaker is given a proper maintenance by a specialized Schenker technician. The warranty covers faults due to defected materials and parts. It is limited to the replacement or repair of faulty parts. The charge for the disconnecting and reinstalling on the vessel, as well as the transport from or to our Service Point (or our factory) shall be at the customers own expenses.
  • Page 7: Identification Of The Unit

    According to removal and disposal, it should be highlighted that the construction materials of the machine are not dangerous for the environment and consist essentially of: Stainless Steel; Plastic; Carbon fibre; Motors, cables and consumable electrical materials; Rubber and polyurethane seals. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 8 ATTENTION Different legislations are in force in the different countries, therefore the prescriptions imposed by the laws and by the agencies designated by the Countries must be observed. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 9: Presentation Of The Product

    The watermaker unit is transported in a cardboard box. Dimensions and weight are indicated in the following table. MATERIALS HANDLING fig. 3-1 Model L cm. W cm. H cm. Weight Kg. ZEN30 Packaging dimensions and weight tab.3-1 Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 10: Stockage

    3.3 Packaging 3.3.1 Packaging contents PACKAGING FIG. 3-2 ZEN 30 Watermaker Pump group Active carbon filter with electrovalve 5 microns filter with accumulator Net filter Non-return valve with Tee fitting...
  • Page 11: Attached Documents

    Do not store the unit under temperature below 5°C and above 45 °C DOCUMENTS INCLUDED IN THE PACKAGING FIG. 3-3 3.5 Technical data WATERMAKER WATERMAKER DIMENSIONS FIG. 3-4 Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 12: Features Of The Product

    (electric safety requirements) 3.6 Features of the product The fresh water produced by a Schenker watermaker, obtained by clean seawater, has a high purity. Despite this, the potability may not be guaranteed: bacterium caused by non-observance of shutdown and cleaning procedures may be present in the watermaker.
  • Page 13: Advantages Of The Energy Recovery System

    Functioning principles The Schenker watermakers, as an alternative to the high-pressure pumps of traditional systems, use the ENERGY RECOVERY SYSTEM patented device, which amplifies the pressure of common low-pressure pumps, and recover all the hydraulic energy back from the membranes, allowing a high energy efficiency.
  • Page 14: Composition Of The Machine

    The device has to be pre-charged with air through the Schrader valve. The pressure is about 4 Bar. The accumulator is already pre-charged to the correct pressure. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 15: Watermaker Group

    FIG. 3-7 Watermaker outlet/discharge Watermaker inlet Reverse osmosis membranes Fresh water production WATERMAKER GROUP (FRONT VIEW W/O COVER) FIG. 3-8 Reset valve Positioner knob Depressurization valve Antishock Manometer Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 16 ERS in case of a system block. It must be opened before screwing in the valve positioner. Antishock. It is a small accumulator. Its function is to stabilize the cycling of the unit. Schenker Italia THE PRESENT MANUAL BELONGS TO -...
  • Page 17: Accessories

    It stops leaking of fresh water from the seacock while the washing procedure starts. Mesh filter. The machine is equipped with a strainer to protect the pump from macro sediments. This is placed between the seacock and the pump. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 18: Installation

    Once an installation plan has been made, it is recommended to make a schematic drawing of the hydraulic and electric connections and attach them to the manual for future reference. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 19: Components Installation

    Otherwise a shelf is necessary as base to support the weight of the watermaker. The brackets are colour-coded according to their position. L BRACKETS FIG. 4-1 VERTICAL AND HORIZONTAL FIXING FIG. 4-2 Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 20 4 –INSTALLATION COD. 30Z12/24.B.2021 INSTALLING PROCEDURE FIG. 4-3 POSSIBLE CONFIGURATIONS FIG. 4-4 For a complete installation, antivibration rubber stickers are provided. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 21 This can be done by making use of the fittings provided. HORIZONTAL FIXING FIG. 4-6 3/8” Nipple 3/8” male to 1/8” female reducer 3/8” 90°-Degree Elbow Manometer Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 22: Accessories

    In case of powerboats with a cruising speed above 15 knot, it is advised to make a small hole (8 mm. diameter) on the back of the shape, in order to reduce dynamic prevalence during navigation. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 23: Fresh Water Connection For Flushing

    It is possible to use a tee fitting on existing discharge hoses (ie: tap discharges) provided that there are no returns of dirty water back to the watermaker. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 24: Hydraulic Connections

    Plumb to pressure side of boat fresh water system Reinforced hose PN10 min int. dia. 16 mm. “Armorvin” type hose int. dia. 16 HYDRAULIC CONNECTION AND PIPES FIG. 4-8 Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 25 Low pressure connections – ¼’’ fittings, Small plastic blue • max 3 bar pipe 6x8mm provided within Watermaker - fresh water tank the scope of supply Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 26 It is possible, in case of metal tanks, to make a ¼” threaded hole to connect the supplied male connector. Another option is to use the tee fitting into the tank air vent hose. There are no particular limits on the connection length. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 27: Electric Connections

    The remote control panel can be connected through the pre-wired multiple cable of a 10mt standard length provided. It is possible to request to the factory a longer cable if necessary. REMOTE CONTROL PANEL FIG. 4-10 Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 28: Electric Connections: Wires (Zen 30 12/24V Dc)

    30Z12/24.B.2021 4.5.2 Electric connections: wires (ZEN 30 12/24V DC) The 12/24 V power supply, from the service batteries, must be connected to the +/- clamps on the card of the computer box. A 16 Ampere automatic circuit breaker for 12V systems must be installed on the power supply, while a 10 Ampere for 24V systems.
  • Page 29 4 –INSTALLATION COD. 30Z12/24.B.2021 ELECTRIC MAIN BOX SCHEME ZEN 30 12/24V DC FIG. 4-10 Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 30: Functioning And Use

    The first start-up procedure is necessary to start a new system, after a filter replacement or a chemical washing. The start-up procedure is mainly aimed to purge the air in the system and into the hoses. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 31: Preliminary Checks Before Proceeding With The Start-Up Procedure

    4. After 2-3 minutes, close the depressurization valve. The system starts going under pressure and the fresh water production begins. Check the working pressure of the unit is correct (6,5 – 7,5 bar). Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 32: Normal Operating Procedure

    1. Push ON/OFF to start the watermaker. 2. Push FLUSHING to flush and stop the watermaker. The watermaker will activate a flushing cycle then it will stop after 1 minute. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 33: Working Cycle With Timer

    In this case the system has to be manually restarted. Although this circumstance might be very unusual, it does not damage the system, but it is necessary to reset the valve with the following simple procedure: Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 34 Normally 18 complete turns at least are needed. 4. Unscrew the positioner knob back to its original position, until it can be turned no more. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 35 5 – FUNCTIONING AND USE COD. 30Z12/24.B.2021 5. Close the reset valve (lever in vertical position). 6. Close the depressurization valve (screw the valve). 7. Restart the system. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 36: Maintenance (Routine And Special)

    2- 3 minutes the depressurization valve. Unscrew the filter housing counter clockwise by using the specific key provided Replace the active carbon Once per year fibre filter Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 37: Check The Watermaker Working Pressure

    The purpose of the shutdown is to flush the system. This might be useful in order to prevent the system from the creation of organic and inorganic sediments, as well as inhibit the growth of bacteria that could reduce the reverse osmosis membranes efficiency. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 38: Necessary Equipment

    3. A bottle of powder SCHENKER CLEANING 1 (SC1). The solution must be prepared following the instruction indicated on the bottle label, and using unchlorinated water (for instance water produced by the system can be an option).
  • Page 39: Shutdown Operating Procedure

    Pipes under the free water surface 3. Check they are well submerged in the solution and don't suck air. 4. Open the depressurization valve. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 40 It is necessary to perform the first start-up procedure when restarting the plant after a shutdown procedure, in order to purge the air and drain out chemicals in the systems. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 41: Antifreeze Procedure (Winterizing Procedure In Cold Climate - Under 5°C)

    FIG. 6-2 hoses. ATTENTION Before proceeding with any kind of service, it is strongly recommended to read carefully the instructions contained in this manual. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 42: Periodic Maintenance

    The accumulator is factory loaded at a pressure of about 4 bar. The charging pressure of the dampener must be periodically checked. Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 43: Troubleshooting

    Purge air by opening for a while the pressure valve Clogged filters Replace filters Low production / high pressure Clogged membranes Perform washing with SC1 (> 9 Bar) Cold seawater Normal condition Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...
  • Page 44: Suggested Spare Parts

    CRUISING KIT CRKZ30 SPARE PUMP SM-MOD 30/60 12V SP36/12 SPARE PUMP SM-MOD 30/60 24V SP36/24 MEMBRANE 2521 M2521 PORTABLE SALINITY TESTER PRESSURE TRANSDUCER SPARE SEALS KIT ZEN30 SSZ3 Schenker Italia THE PRESENT MANUAL BELONGS TO - - ALL RIGHTS RESERVED...