AIMS Power PWRI30012S Instruction Manual

AIMS Power PWRI30012S Instruction Manual

Dc to ac pure sine power inverter

Advertisement

Quick Links

DC TO AC PURE SINE POWER INVERTER
PWRI30012S / PWRI30024S
INSTRUCTION MANUAL
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PWRI30012S and is the answer not in the manual?

Questions and answers

Summary of Contents for AIMS Power PWRI30012S

  • Page 1 DC TO AC PURE SINE POWER INVERTER PWRI30012S / PWRI30024S INSTRUCTION MANUAL...
  • Page 2: Warning And Safety

    A. INTRODUCTION The AIMS Power pure sine inverter product line is used for back-up or mobile power. The pure sine product line is ideal for sensitive equipment and provides clean power, which is more efficient for back-up power applications. The power inverter transforms DC (direct current) electricity into AC (alternating current) power that can be used for running a wide variety of small devices using a battery.
  • Page 3: Inverter Features

    13. The power inverter will output the same AC power as utility power, please treat the AC outlets as carefully as you would your home AC outlets. Do not put anything other than an electrical appliance into the output terminal. It may cause shock or fire.
  • Page 4 5. We recommend mounting the inverter on something stable to prevent it from bouncing. Impact shock could result in damage to your unit. Be sure to use all four mounting screws for optimal stability. Mount in a location that can support the weight of the inverter.
  • Page 5 F. CONNECTION 1. Grounding (not all inverters have a ground terminal) The power inverter has a terminal on the rear panel marked " Grounding "or "≡". This is used to connect the chassis of the power inverter to ground. The ground terminal has already been connected to the ground wire of the AC output receptacle through the inverter.
  • Page 6 6. The USB port on this unit can provide a stable line of 5V DC current. The maximum current is 1000 mA. Be sure to double check your device to make sure it doesn't exceed these requirements. SOFT START TECHNOLOGY The soft start technology built into this inverter protects the unit from delivering too much AC power at once by gradually increasing the AC voltage pushed out.
  • Page 7 115 VAC inverter is 1,250 VAC. For 230 VAC or dual voltage inverters, the hi-pot voltage is 1,500 VAC. This Aims power inverter is hi-pot tested before it leaves the factory. Hi-Pot testing is used to detect any electrical leakage between live metal components and the frame of the machine that is connected to earth ground.
  • Page 8: Troubleshooting Tips

    TROUBLESHOOTING TIPS Fault / Display Cause Solutions Low input DC voltage Recharge or replace the battery Do not use it when the battery is charging. Check the rated voltage of the battery and make sure it is in within the range of the input voltage.
  • Page 9: Specifications

    SPECIFICATIONS MODEL NO PWRI30012S PWRI30024S DC Input Voltage 12V (9.8-16V) 24V (19-32V) Pure Sine Wave THD Pure Sine Wave THD Output Wave Form <3% <3% Output Power 300W 300W Surge Power Capacity 600W for 40 milsec 600W for 40 milsec...
  • Page 10: Warranty

    AIMS be liable for indirect, special or consequential damages. This warranty only applies to AIMS Power branded products. All other name brand products are warranted by and according to their respective manufacturer. Please do not attempt to return non-AIMS Power branded products to AIMS Power.